Psychometric properties of the Zephyr bioharness device: a systematic review
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Technological development and improvements in Wearable Physiological Monitoring devices, have facilitated the wireless and continuous field-based monitoring/capturing of physiologic measures in healthy, clinical or athletic populations. These devices have many applications for prevention and rehabilitation of musculoskeletal disorders, assuming reliable and valid data is collected. The purpose of this study was to appraise the quality and synthesize findings from published studies on psychometric properties of heart rate measurements taken with the Zephyr Bioharness device. METHODS: We searched the Embase, Medline, PsycInfo, PuMed and Google Scholar databases to identify articles. Articles were appraised for quality using a structured clinical measurement specific appraisal tool. Two raters evaluated the quality and conducted data extraction. We extracted data on the reliability (intra-class correlation coefficients and standard error of measurement) and validity measures (Pearson/Spearman's correlation coefficients) along with mean differences. Agreement parameters were summarised by the average biases and 95% limits of agreement. RESULTS: A total of ten studies were included: quality ratings ranged from 54 to 92%. The intra-class correlation coefficients reported ranged from 0.85-0.98. The construct validity coefficients compared against gold standard calibrations or other commercially used devices, ranged from 0.74-0.99 and 0.67-0.98 respectively. Zephyr Bioharness agreement error ranged from - 4.81 (under-estimation) to 3.00 (over-estimation) beats per minute, with varying 95% limits of agreement, when compared with gold standard measures. CONCLUSION: Good to excellent quality evidence from ten studies suggested that the Zephyr Bioharness device can provide reliable and valid measurements of heart rate across multiple contexts, and that it displayed good agreements vs. gold standard comparators - supporting criterion validity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“Numerous WPM devices have been introduced to the market [4, 5] with a range of capabilities and target audiences.”
BackgroundBrage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151 · cited 1×
“to provide an estimate of energy expenditure, providing an easier and inexpensive alternative [12].”
Background
Cited by
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
The effect of green walking on heart rate variability: a pilot crossover study
de Brito, J. N., Pope, Z. C., Mitchell, N. R., Schneider, I. E., Larson, J. M., Horton, T. H., & Pereira, M. A. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109408 · Cited by 67
An investigation into the effectiveness of using acoustic touch to assist people who are blind
Zhu, H. Y., Hossain, S. N., Jin, C., Singh, A. K., Nguyen, M. T. D., Deverell, L., Nguyen, V., Gates, F. S., Fernandez, I. G., Melencio, M. V., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0290431 · Cited by 16
Nazari, G., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A. (2019) · Physiotherapy Canada · doi:10.3138/ptc.2018-25 · Cited by 15
Self-citation
Metadata
- Authors
- Nazari, G., Bobos, P., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A.
- Venue
- BMC Sports Science, Medicine and Rehabilitation
- Published
- 2018-02-21
- Volume
- 10
- Issue
- 1
- Pages
- 6-6
- ISSN
- 2052-1847 (ISSN-L)
- OpenAlex
- W2801651275
- Cited by
- 101
- References
- 4
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Psychometric properties of the Zephyr bioharness device: a systematic review. https://app.cochat.ai/papers/10.1186/s13102-018-0094-4
- The paper
- Nazari, G., Bobos, P., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A. (2018). Psychometric properties of the Zephyr bioharness device: a systematic review. BMC Sports Science, Medicine and Rehabilitation. https://doi.org/10.1186/s13102-018-0094-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.