Prediction of fluid responsiveness. What’s new?
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Although the administration of fluid is the first treatment considered in almost all cases of circulatory failure, this therapeutic option poses two essential problems: the increase in cardiac output induced by a bolus of fluid is inconstant, and the deleterious effects of fluid overload are now clearly demonstrated. This is why many tests and indices have been developed to detect preload dependence and predict fluid responsiveness. In this review, we take stock of the data published in the field over the past three years. Regarding the passive leg raising test, we detail the different stroke volume surrogates that have recently been described to measure its effects using minimally invasive and easily accessible methods. We review the limits of the test, especially in patients with intra-abdominal hypertension. Regarding the end-expiratory occlusion test, we also present recent investigations that have sought to measure its effects without an invasive measurement of cardiac output. Although the limits of interpretation of the respiratory variation of pulse pressure and of the diameter of the vena cava during mechanical ventilation are now well known, several recent studies have shown how changes in pulse pressure variation itself during other tests reflect simultaneous changes in cardiac output, allowing these tests to be carried out without its direct measurement. This is particularly the case during the tidal volume challenge, a relatively recent test whose reliability is increasingly well established. The mini-fluid challenge has the advantage of being easy to perform, but it requires direct measurement of cardiac output, like the classic fluid challenge. Initially described with echocardiography, recent studies have investigated other means of judging its effects. We highlight the problem of their precision, which is necessary to evidence small changes in cardiac output. Finally, we point out other tests that have appeared more recently, such as the Trendelenburg manoeuvre, a potentially interesting alternative for patients in the prone position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malbrain, M. L. N. G., Van Regenmortel, N., Saugel, B., De Tavernier, B., Van Gaal, P.-J., Joannes-Boyau, O., Teboul, J.-L., Rice, T. W., Mythen, M., & Monnet, X. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0402-x · Cited by 632 · cited 2×
“This means that many patients will inadvertently receive fluids while there is no cardiac output response [1, 2].”
BackgroundSelf-citationEvans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005357 · Cited by 513 · cited 2×
“In this context, a dynamic measurement of preload responsiveness is recommended, as during sepsis for example [12].”
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482 · cited 4×
“The test not only has good sensitivity and specificity (85 and 91%, respectively) [9], but also very good positive and negative predictive values and likelihood ratios [11].”
BackgroundInfluentialSelf-citationCannesson, M. P., Desebbe, O., Rosamel, P., Delannoy, B., Robin, J., Bastien, O. H., & Lehot, J.-J. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen133 · Cited by 377 · cited 1×
“The respiratory variation of the perfusion index, quantified by the pleth variability index, has been demonstrated to indicate preload responsiveness [25], even though some poorer results have been reported in critically ill patients receiving norepinephrine [26], which may alter the quality of the plethysmographic si…”
ResultMuller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343 · cited 1×
“Therefore, the idea of administering only a “mini-fluid challenge”, performed with a quite small volume of fluid to assess preload responsiveness is interesting [80].”
BackgroundLess invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationMalbrain, M. L. N. G., Langer, T., Annane, D., Gattinoni, L., Elbers, P., Hahn, R. G., De laet, I., Minini, A., Wong, A., Ince, C., et al. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00679-3 · Cited by 323 · cited 1×
“This means that many patients will inadvertently receive fluids while there is no cardiac output response [1, 2].”
BackgroundComparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308 · cited 3×
“A large study confirmed that changes in diameter, especially of the inferior vena cava, have low diagnostic sensitivity and specificity in detecting preload responsiveness, as assessed by the PLR test [72].”
BackgroundMethodInfluentialMonnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Self-citationPassive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289 · cited 1×
“The advantage of this “self-transfusion” of roughly 300 mL of blood [6] is that it is reversible.”
BackgroundSelf-citationFluid Response Evaluation in Sepsis Hypotension and Shock
Douglas, I. S., Alapat, P. M., Corl, K. A., Exline, M. C., Forni, L. G., Holder, A. L., Kaufman, D. A., Khan, A., Levy, M. M., Martin, G. S., et al. (2020) · Chest · doi:10.1016/j.chest.2020.04.025 · Cited by 271 · cited 1×
“In addition, the trial that included the largest number of patients evidenced a reduction in the need for renal replacement therapy and for mechanical ventilation in the intervention group [104].”
BackgroundPreisman, S., Kogan, S., Berkenstadt, H., & Perel, A. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei262 · Cited by 269 · cited 1×
“This test looks like the respiratory systolic variation test, which has been developed years ago [91].”
Benes, J., Giglio, M., Brienza, N., & Michard, F. (2014) · Critical Care · doi:10.1186/s13054-014-0584-z · Cited by 257 · cited 1×
“This meta-analysis confirmed the results of an earlier one, performed specifically in post-surgical patients, showing that a goal-directed strategy based on dynamic parameters decreased post-surgical morbidity and ICU length of stay [100].”
ResultMonnet, X., Julien, F., Ait-Hamou, N., Lequoy, M., Gosset, C., Jozwiak, M., Persichini, R., Anguel, N., Richard, C., & Teboul, J.-L. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318275cece · Cited by 255 · cited 1×
“Due to the non-linear relationship between oxygen consumption and oxygen delivery in some cases, the fluid-induced increase in cardiac output is not always accompanied by improved tissue oxygenation [98].”
BackgroundSelf-citationCherpanath, T. G. V., Hirsch, A., Geerts, B. F., Lagrand, W. K., Leeflang, M. M., Schultz, M. J., & Groeneveld, A. B. J. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001556 · Cited by 253 · cited 1×
“The reliability of the PLR test for detecting preload responsiveness is well established, after the publication of numerous studies [8] and some meta-analyses [9, 10].”
BackgroundMyatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002183 · Cited by 236 · cited 3×
“Moreover, the diagnostic thresholds differ slightly between the few available studies (Table 2), which in addition expressed the change in PPV either as an absolute value [30, 52, 65]} or as a percent change [56, 66, 67], or both [29].”
BackgroundMethodSelf-citationEffects of norepinephrine on mean systemic pressure and venous return in human septic shock*
Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318260c6c3 · Cited by 218 · cited 2×
“Alternatives to fluid may be considered for improving the haemodynamic status, as using the preload effect of norepinephrine in septic shock patients [95, 96] or simply decreasing the level of PEEP, for instance.”
BackgroundSelf-citationArterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200 · cited 14×
“This was confirmed in a meta-analysis of 11 studies (1015 patients) performed in surgical ICU patients and in which a strategy based on SVV reduced the ICU and hospital lengths of stay and tended to decrease mortality [101].”
BackgroundInfluentialSelf-citationBednarczyk, J. M., Fridfinnson, J. A., Kumar, A., Blanchard, L., Rabbani, R., Bell, D., Funk, D., Turgeon, A. F., Abou-Setta, A. M., & Zarychanski, R. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002554 · Cited by 192 · cited 1×
“In a 2017 meta-analysis including 13 trials (1652 patients), 12 of which were performed in post-surgical patients, a fluid strategy based on a fluid responsiveness assessment significantly decreased mortality and ICU length of stay [99].”
BackgroundRespiratory variations in right atrial pressure predict the response to fluid challenge
Magder, S. A., Georgiadis, G., & Cheong, T. H. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90032-3 · Cited by 188 · cited 1×
“For the inferior vena cava, while it is true that its intramural pressure, the central venous pressure, varies more in amplitude in the event of preload responsiveness [73], which tends to vary its diameter, it is not the only factor that comes into play.”
BackgroundWhat is the lowest change in cardiac output that transthoracic echocardiography can detect?
Jozwiak, M., Mercado, P., Teboul, J.-L., Benmalek, A., Gimenez, J., Dépret, F., Richard, C., & Monnet, X. (2019) · Critical Care · doi:10.1186/s13054-019-2413-x · Cited by 177
Self-citationPréau, S., Bortolotti, P., Colling, D., Dewavrin, F., Colas, V., Voisin, B., Onimus, T., Drumez, É., Durocher, A., Redheuil, A. B., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002090 · Cited by 172 · cited 1×
“However, in septic non-intubated patients, a recent study suggested that preload responsiveness was detected by changes in the diameter of the inferior vena cava induced by a standardized respiratory manoeuvre [77].”
BackgroundPierrakos, C., Velissaris, D., Scolletta, S., Heenen, S., De Backer, D., & Vincent, J.-L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-011-2457-0 · Cited by 171 · cited 1×
“During a classic fluid challenge, it is well demonstrated that changes in arterial pressure, even in arterial pulse pressure—best related to stroke volume—follow changes in cardiac output only very imprecisely [14, 82].”
BackgroundMonnet, X., Bataille, A., Magalhaes, E., Barrois, J., Le Corre, M., Gosset, C., Guerin, L., Richard, C., & Teboul, J.-L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2693-y · Cited by 159
Self-citationApplicability of pulse pressure variation: how many shades of grey?
Michard, F., Chemla, D., & Teboul, J. (2015) · Critical Care · doi:10.1186/s13054-015-0869-x · Cited by 152 · cited 2×
“However, PPV and SVV are limited by the fact that they cannot be used in many clinical conditions, which can be easily remembered through the acronym LIMITS [60]: Low heart rate/respiratory rate ratio (extremely high respiratory rates), which creates some false negatives, Irregular heartbeats (false positives), Mechan…”
BackgroundSelf-citationMallat, J., Meddour, M., Durville, E., Lemyze, M., Pepy, F., Temime, J., Vangrunderbeeck, N., Tronchon, L., Thévenin, D., & Tavernier, B. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev222 · Cited by 135 · cited 2×
“Two small studies recently showed that the decrease in PPV and SVV during a 100 mL mini-fluid challenge predicted the response to volume expansion with acceptable reliability [63, 64] (Table 1).”
BackgroundMethodTigabu, B. M., Davari, M., Kebriaeezadeh, A., & Mojtahedzadeh, M. (2018) · Journal of Critical Care · doi:10.1016/j.jcrc.2018.08.018 · Cited by 134 · cited 2×
“It is now well established that an increase in fluid balance during an ICU stay [3] or after cardiac surgery [4] worsens patient outcome, regardless of other factors of severity.”
BackgroundMonnet, X., Letierce, A., Hamzaoui, O., Chemla, D., Anguel, N., Osman, D., Richard, C., & Teboul, J. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820edcf0 · Cited by 133 · cited 2×
“Even changes in arterial pulse pressure, which is best related to stroke volume, only imperfectly follow the effects of PLR on cardiac output, as is the case for the fluid challenge [14].”
BackgroundSelf-citationMonnet, X., Dres, M., Ferré, A., Teuff, G. L., Jozwiak, M., Bleibtreu, A., Deley, M. L., Chemla, D., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes182 · Cited by 132 · cited 1×
“The test not only has good sensitivity and specificity (85 and 91%, respectively) [9], but also very good positive and negative predictive values and likelihood ratios [11].”
BackgroundSelf-citationSánchez, J. I. A., Ruiz, J. D., Fernández, J. J. D., Zúñiga, W. F. A., Ospina-Tascón, G. A., & Martínez, L. (2021) · Annals of Intensive Care · doi:10.1186/s13613-021-00817-5 · Cited by 128 · cited 3×
“Reliability After relatively small studies, two recent meta-analyses confirmed the reliability of the mini-fluid challenge [45, 54].”
BackgroundResultMessina, A., Robba, C., Calabrò, L. A., Zambelli, D., Iannuzzi, F., Molinari, E., Scarano, S., Battaglini, D., Baggiani, M., Mattei, G. D., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03464-1 · Cited by 127 · cited 1×
“A recent metaanalysis including 21 randomized control trials enrolling 2729 patients found that goal-directed therapy was associated with a reduction in post-operative complications and a trend toward reduced mortality [103].”
BackgroundBarjaktarević, I., Toppen, W., Hu, S. B., Montoya, E. A., Ong, S. L., Buhr, R. G., David, I. J., Wang, T. S., Rezayat, T., Chang, S. Y., et al. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003356 · Cited by 122 · cited 1×
“Indeed, published studies are highly contradictory, some showing that these arterial flows follow the changes induced by the PLR test [33], while others demonstrate the method is unreliable [34, 35].”
ResultThe accuracy of noninvasive cardiac output and pressure measurements with finger cuff
Ameloot, K., Palmers, P., & Malbrain, M. L. N. G. (2015) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000198 · Cited by 113 · cited 1×
“This is also true when PLR is assessed with the volume clamp technique, which estimates cardiac output through the uncalibrated analysis of an arterial curve obtained noninvasively through a finger cuff [17].”
MethodMessina, A., Dell’Anna, A. M., Baggiani, M., Torrini, F., Maresca, G. M., Bennett, V., Saderi, L., Sotgiu, G., Antonelli, M. M., & Cecconi, M. (2019) · Critical Care · doi:10.1186/s13054-019-2545-z · Cited by 113 · cited 3×
“Reliability After relatively small studies, two recent meta-analyses confirmed the reliability of the mini-fluid challenge [45, 54].”
BackgroundResultJozwiak, M., Dépret, F., Teboul, J., Alphonsine, J.-E., Lai, C., Richard, C., & Monnet, X. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002704 · Cited by 112
Self-citationBeurton, A., Teboul, J., Gavelli, F., Gonzalez, F. A., Girotto, V., Galarza, L., Anguel, N., Richard, C., & Monnet, X. (2019) · Critical Care · doi:10.1186/s13054-019-2306-z · Cited by 109 · cited 2×
“some patients could be a limitation of the method [28].”
BackgroundMethodSelf-citationGarcía, M. I. M., Cano, A. G., Romero, M. Á. G., Pintado, R. M., Madueño, V. P., & Monrové, J. C. D. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-9 · Cited by 107
Monnet, X., Guérin, L., Jozwiak, M., Bataille, A., Fournier, J., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes373 · Cited by 105 · cited 1×
“The respiratory variation of the perfusion index, quantified by the pleth variability index, has been demonstrated to indicate preload responsiveness [25], even though some poorer results have been reported in critically ill patients receiving norepinephrine [26], which may alter the quality of the plethysmographic si…”
ResultSelf-citationPerioperative hemodynamic optimization: from guidelines to implementation—an experts’ opinion paper
Fellahi, J.-L., Futier, E., Vaisse, C., Collange, O., Huet, O., Loriau, J., Gayat, É., Tavernier, B., Biais, M., Asehnoune, K., et al. (2021) · Annals of Intensive Care · doi:10.1186/s13613-021-00845-1 · Cited by 105 · cited 2×
“Several of these studies and their meta-analyses [102] have shown that such a goal-directed approach is beneficial, especially in decreasing post-operative complications.”
BackgroundYonis, H., Bitker, L., Aublanc, M., Périnel, S., Riad, Z., Lissonde, F., Louf-Durier, A., Debord, S., Gobert, F., Tapponnier, R., et al. (2017) · Critical Care · doi:10.1186/s13054-017-1881-0 · Cited by 101 · cited 4×
“One study showed that an increase in cardiac output during such a manoeuvre correctly detected preload responsiveness (Table 1) [56].”
BackgroundResultInfluentialRichard, J.-C., Bayle, F., Bourdin, G., Leray, V., Debord, S., Delannoy, B., Stoian, A. C., Wallet, F., Yonis, H., & Guerin, C. (2015) · Critical Care · doi:10.1186/s13054-014-0734-3 · Cited by 100
Jacquet‐Lagrèze, M., Bouhamri, N., Portran, P., Schweizer, R., Baudin, F., Lilot, M., Fornier, W., & Fellahi, J.-L. (2019) · Critical Care · doi:10.1186/s13054-019-2560-0 · Cited by 99 · cited 1×
“Preload responsiveness could even be detected by the effects of the PLR test on capillary refill time [32], although it reflects skin perfusion and sympathetic vasoconstriction without being a direct surrogate of cardiac output.”
BackgroundMini-fluid Challenge of 100 ml of Crystalloid Predicts Fluid Responsiveness in the Operating Room
Biais, M., de Courson, H., Lanchon, R., Pereira, B., Bardonneau, G., Griton, M., Sesay, M., & Nouette-Gaulain, K. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001753 · Cited by 94 · cited 1×
“Note, however, that even with this technique, the reliability of the mini-fluid challenge is lower if the volume infused is only 50 mL [83].”
BackgroundPrediction of fluid responsiveness in ventilated patients
Jozwiak, M., Monnet, X., & Teboul, J. (2018) · Annals of Translational Medicine · doi:10.21037/atm.2018.05.03 · Cited by 94 · cited 2×
“What do we already know about the test? As PPV and SVV, the end-expiratory occlusion (EEO) test detects preload dependence by taking advantage of cardiopulmonary interactions [41].”
BackgroundSelf-citationTargeted Fluid Minimization Following Initial Resuscitation in Septic Shock
Chen, C., & Kollef, M. H. (2015) · Chest · doi:10.1378/chest.15-1525 · Cited by 92
My patient has received fluid. How to assess its efficacy and side effects?
Monnet, X., & Teboul, J. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0400-z · Cited by 87
Self-citationVincent, J., Cecconi, M., & Backer, D. D. (2020) · Critical Care · doi:10.1186/s13054-020-03443-y · Cited by 87 · cited 1×
“The fluid challenge has for years been proposed to guide fluid therapy [79].”
BackgroundTidal volume challenge to predict fluid responsiveness in the operating room
Messina, A., Montagnini, C., Cammarota, G., Rosa, S. D., Giuliani, F., Muratore, L., Corte, F. D., Navalesi, P., & Cecconi, M. (2019) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000998 · Cited by 87 · cited 2×
“What’s new? Recent publications suggest the interest in the Vt challenge in the operating room context [66, 67], where the PLR test is not feasible during many interventions.”
BackgroundThe end-expiratory occlusion test: please, let me hold your breath!
Gavelli, F., Teboul, J., & Monnet, X. (2019) · Critical Care · doi:10.1186/s13054-019-2554-y · Cited by 84
Self-citationGavelli, F., Shi, R., Teboul, J., Azzolina, D., & Monnet, X. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00682-8 · Cited by 81 · cited 1×
“The diagnostic threshold is a 5% increase in cardiac output [43] (Table 2).”
BackgroundSelf-citationIntra-Abdominal Hypertension Is Responsible for False Negatives to the Passive Leg Raising Test
Beurton, A., Teboul, J., Girotto, V., Galarza, L., Anguel, N., Richard, C., & Monnet, X. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003808 · Cited by 78 · cited 1×
“More recently, a study suggested that intra-abdominal hypertension, which would reduce the splanchnic blood volume mobilized during PLR, or even interrupt the inferior vena cava flow by a waterfall phenomenon, would generate some false negatives [39].”
BackgroundSelf-citationSilva, S., Jozwiak, M., Teboul, J., Persichini, R., Richard, C., & Monnet, X. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a2323 · Cited by 78 · cited 1×
“In addition, the EEO test has been shown to be reliable regardless of the level of respiratory driving pressure [55].”
Self-citationBiais, M., Lanchon, R., Sesay, M., Gall, L. L., Pereira, B., Futier, E., & Nouette‐Gaulain, K. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001459 · Cited by 75
Taccheri, T., Gavelli, F., Teboul, J., Shi, R., & Monnet, X. (2021) · Critical Care · doi:10.1186/s13054-021-03515-7 · Cited by 75 · cited 4×
“Indeed, it has recently been reported that the decrease in PPV induced by a PLR test, reflecting the decrease in preload responsiveness induced by the preload challenge, detects preload responsiveness [29, 30] (Table 1).”
BackgroundMethodInfluentialSelf-citationMessina, A., Robba, C., Calabrò, L. A., Zambelli, D., Iannuzzi, F., Molinari, E., Scarano, S., Battaglini, D., Baggiani, M., Mattei, G. D., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03629-y · Cited by 74 · cited 2×
“It is now well established that an increase in fluid balance during an ICU stay [3] or after cardiac surgery [4] worsens patient outcome, regardless of other factors of severity.”
BackgroundEquilibrating SSC guidelines with individualized care
Vincent, J., Singer, M., Einav, S., Moreno, R. P., Wendon, J. A., Teboul, J., Bakker, J., Glenn Hernández, P., Annane, D., de Man, A., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03813-0 · Cited by 73
Self-citationGuérin, L., Teboul, J., Persichini, R., Dres, M., Richard, C., & Monnet, X. (2015) · Critical Care · doi:10.1186/s13054-015-1115-2 · Cited by 70 · cited 1×
“What do we already know about the test? Transferring a patient from a semi-recumbent position to a position where the trunk is horizontal and the lower limbs are elevated at 30–45° mobilizes blood from the splanchnic territory and the lower limbs and significantly increases mean systemic pressure, the upstream pressur…”
BackgroundSelf-citationHuang, H., Shen, Q., Liu, Y., Xu, H., & Fang, Y. (2018) · Critical Care · doi:10.1186/s13054-018-2063-4 · Cited by 67
Biais, M., Larghi, M., Henriot, J., de Courson, H., Sesay, M., & Nouette‐Gaulain, K. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002322 · Cited by 65 · cited 1×
“However, several studies which clearly demonstrated the validity of the EEO test had included ventilated patients with a Vt less than 8 mL/kg, and even less than 7 mL/kg [42, 53].”
BackgroundDres, M., Teboul, J., Anguel, N., Guerin, L., Richard, C., & Monnet, X. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3653-0 · Cited by 64
Self-citationAdda, I., Lai, C., Teboul, J., Guerin, L., Gavelli, F., & Monnet, X. (2021) · Critical Care · doi:10.1186/s13054-021-03711-5 · Cited by 63 · cited 2×
“Alternatives to fluid may be considered for improving the haemodynamic status, as using the preload effect of norepinephrine in septic shock patients [95, 96] or simply decreasing the level of PEEP, for instance.”
Self-citationHofkens, P., Verrijcken, A., Merveille, K., Neirynck, S., Regenmortel, N. V., laet, I. D., Schoonheydt, K., Dits, H., Bein, B., Huber, W., et al. (2014) · Anaesthesiology Intensive Therapy · doi:10.5603/ait.a2014.0068 · Cited by 63 · cited 1×
“Considering all these limitations, it is surprising to see that vena cava distensibility is often thought to be the key index for assessing fluid requirements in point-of-care ultrasound [78].”
BackgroundParameters of fluid responsiveness
Shi, R., Monnet, X., & Teboul, J. (2020) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000723 · Cited by 60 · cited 1×
“What do we already know about the index? Variation in the diameter of the vena cava has long been proposed for the detection of preload dependence in mechanically ventilated patients [68].”
BackgroundSelf-citationPassive leg raising for assessment of volume responsiveness: a review
Mesquida, J., Gruartmoner, G., & Ferrer, R. (2017) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000404 · Cited by 55 · cited 2×
“In addition, the test does not depend on ventilation and heart rate, and it remains reliable in patients with spontaneous ventilation and cardiac arrhythmia [7].”
BackgroundCaplan, M., Durand, A., Bortolotti, P., Colling, D., Goutay, J., Duburcq, T., Drumez, É., Rouzé, A., Nseir, S., Howsam, M., et al. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00786-1 · Cited by 54 · cited 1×
“Nevertheless, the echographic measurement should be performed 4 cm from the right atrium [74], which might be challenging, especially in the semi-recumbent position during respiratory distress [76].”
BackgroundToupin, F., Clairoux, A., Deschamps, A., Lebon, J.-S., Lamarche, Y., Lambert, J., Fortier, A., & Denault, A. Y. (2016) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-016-0677-z · Cited by 51
Evaluation of least significant changes of pulse contour analysis-derived parameters
de Courson, H., Ferrer, L., Cane, G., Verchère, E., Sesay, M., Nouette‐Gaulain, K., & Biais, M. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0590-z · Cited by 50 · cited 2×
“The pulse wave contour analysis, a real-time and very precise measurement (the smallest detectable significant change is of the order of only 1–2% [47]) is perfectly adapted but is an expensive and invasive technique.”
BackgroundMethodDépret, F., Jozwiak, M., Teboul, J., Alphonsine, J.-E., Richard, C., & Monnet, X. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003522 · Cited by 47 · cited 1×
“When using oesophageal Doppler, which has the same precision issues as cardiac ultrasound, the combination of EEO and end-inspiratory occlusion can also be used [50].”
MethodSelf-citationHamzaoui, O., Shi, R., Carelli, S., Sztrymf, B., Prat, D., Jacobs, F., Monnet, X., Gouëzel, C., & Teboul, J. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2021.05.034 · Cited by 41 · cited 3×
“The test can be used in patients with some spontaneous breathing under mechanical ventilation [30].”
BackgroundSelf-citationBeurton, A., Gavelli, F., Teboul, J., Vita, N. D., & Monnet, X. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004768 · Cited by 40 · cited 4×
“However, a modified version bioreactance system that reduces the cardiac output averaging time to 8 s was recently shown to be quite appropriate [27].”
BackgroundMethodInfluentialSelf-citationClinical trial design for unmet clinical needs: a spotlight on sepsis
Vincent, J., & Sakr, Y. L. (2019) · Expert Review of Clinical Pharmacology · doi:10.1080/17512433.2019.1643235 · Cited by 37
Resuscitation Guided by Volume Responsiveness Does Not Reduce Mortality in Sepsis: A Meta-Analysis
Ehrman, R. R., Gallien, J. Z., Smith, R. K., Akers, K. G., Malik, A. N., Harrison, N. E., Welch, R. D., Levy, P. D., & Sherwin, R. L. (2019) · Critical Care Explorations · doi:10.1097/cce.0000000000000015 · Cited by 35 · cited 1×
“A reduction in mortality, which was not the primary goal of these studies, was not observed, as confirmed in two meta-analyses [107, 108].”
ResultCarotid and femoral Doppler do not allow the assessment of passive leg raising effects
Girotto, V., Teboul, J., Beurton, A., Galarza, L., Guedj, T., Richard, C., & Monnet, X. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0413-7 · Cited by 33 · cited 1×
“Indeed, published studies are highly contradictory, some showing that these arterial flows follow the changes induced by the PLR test [33], while others demonstrate the method is unreliable [34, 35].”
ResultSelf-citationDubin, A., Loudet, C., Edul, V. S. K., Osatnik, J., Ríos, F., Vásquez, D., Pozo, M., Lattanzio, B., Pálizas, F., Klein, F., et al. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00659-7 · Cited by 32
Hongmin, Z., Zhang, Q., Chen, X., Wang, X., & Liu, D. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0589-5 · Cited by 32
Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review
Pickett, J. D., Bridges, E. J., Kritek, P., & Whitney, J. D. (2017) · Critical Care Nurse · doi:10.4037/ccn2017205 · Cited by 32 · cited 1×
“The reliability of the PLR test for detecting preload responsiveness is well established, after the publication of numerous studies [8] and some meta-analyses [9, 10].”
BackgroundDo changes in perfusion index reflect changes in stroke volume during preload-modifying manoeuvres?
de Courson, H., Michard, F., Chavignier, C., Verchère, E., Nouette‐Gaulain, K., & Biais, M. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00445-2 · Cited by 31 · cited 1×
“Interestingly, changes in the plethysmographic perfusion index were tested under the same conditions but had less diagnostic value [89].”
MethodDiagnostic accuracy of inferior vena caval respiratory variation in detecting fluid unresponsiveness
Das, S. K., Choupoo, N. S., Pradhan, D., Saikia, P., & Monnet, X. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000841 · Cited by 31
Self-citationMessina, A., Lionetti, G., Foti, L., Bellotti, E., Marcomini, N., Cammarota, G., Bennett, V., Saderi, L., Sotgiu, G., Corte, F. D., et al. (2021) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001406 · Cited by 29 · cited 1×
“This has been confirmed by a multicentre study involving more than 100 patients in the operating theatre [81] so that one can now reasonably consider that this is a reliable way to detect preload responsiveness (Table 1).”
BackgroundGalarza, L., Mercado, P., Teboul, J., Girotto, V., Beurton, A., Richard, C., & Monnet, X. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.03.013 · Cited by 29 · cited 1×
“This is the case for bioreactance (Starling, Baxter, Deerfield, USA), at least in its latest version, in which the duration over which cardiac output values are averaged and the frequency at which their refreshed display are compatible with the duration of the PLR effects [21].”
BackgroundSelf-citationPrediction of fluid responsiveness in spontaneously breathing patients
Monnet, X., & Teboul, J. (2020) · Annals of Translational Medicine · doi:10.21037/atm-2020-hdm-18 · Cited by 28 · cited 2×
“However, the test is still valid in circumstances that limit the use of PPV and SVV, such as spontaneous breathing, cardiac arrhythmia, low tidal volume (Vt) ventilation, low lung compliance, or right heart failure [38].”
BackgroundSelf-citationSigh maneuver to enhance assessment of fluid responsiveness during pressure support ventilation
Messina, A., Colombo, D., Barra, F. L., Cammarota, G., Mattei, G. D., Longhini, F., Romagnoli, S., DellaCorte, F., Backer, D. D., Cecconi, M., et al. (2019) · Critical Care · doi:10.1186/s13054-018-2294-4 · Cited by 27 · cited 1×
“In the same vein, it was recently proposed that preload responsiveness can be tested by performing four sigh manoeuvres at 0, 15, 25 and 35 cmH2O and by measuring the slope of the drop in systolic blood pressure induced [90].”
BackgroundSi, X., Song, X., Lin, Q., Nie, Y., Zhang, G., Xu, H., Chen, M., Wu, J., & Guan, X. (2020) · Shock · doi:10.1097/shk.0000000000001545 · Cited by 25
Broca, B. D., Garnier, J., Fischer, M.-O., Archange, T., Marc, J., Arab, O. A., Dupont, H., Lorne, E., & Guinot, P. (2016) · Medicine · doi:10.1097/md.0000000000004259 · Cited by 25 · cited 1×
“The decrease in stroke volume during a recruitment manoeuvre (application of continuous positive airway pressure of 30 cm H2O for 30 s [86, 87], or of 25 cmH2O for 25 s [88]) predicted the response to a subsequent bolus of fluid in surgical patients during anaesthesia [86, 88] and during one-lung ventilation [87].”
BackgroundDave, C. V., Shen, J. M., Chaudhuri, D., Herritt, B., Fernando, S. M., Reardon, P. M., Tanuseputro, P., Thavorn, K., Neilipovitz, D., Rosenberg, E., et al. (2018) · Journal of Intensive Care Medicine · doi:10.1177/0885066618805410 · Cited by 22 · cited 1×
“This was confirmed in a meta-analysis of 11 studies (1015 patients) performed in surgical ICU patients and in which a strategy based on SVV reduced the ICU and hospital lengths of stay and tended to decrease mortality [101].”
ResultChowhan, G., Kundu, R., Maitra, S., Arora, M. K., Batra, R. K., Subramaniam, R., Baidya, D. K., & Trikha, A. (2021) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-23764 · Cited by 22 · cited 1×
“Indeed, published studies are highly contradictory, some showing that these arterial flows follow the changes induced by the PLR test [33], while others demonstrate the method is unreliable [34, 35].”
ResultRoehrig, C., Govier, M., Robinson, J. T. C., & Åneman, A. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12822 · Cited by 21 · cited 1×
“More generally, doubts exist regarding the ability of carotid blood flow to track changes in cardiac output [36, 37].”
BackgroundKimura, A., Suehiro, K., Juri, T., Fujimoto, Y., Yoshida, H., Tanaka, K., Mori, T., & Nishikawa, K. (2021) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005375 · Cited by 21
Minini, A., Abraham, P., & Malbrain, M. L. N. G. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2019.12.14 · Cited by 20 · cited 1×
“The results of this single study need to be confirmed [40] but, in the meantime, it is reasonable to advise caution in interpreting the PLR test in cases of intra-abdominal hypertension (Table 1).”
Ma, G., Tu, G.-W., Zheng, J., Zhu, D., Hao, G., Hou, J., Su, Y., Luo, J., Liu, K., & Luo, Z. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.10.002 · Cited by 19 · cited 15×
“Another attractive way to assess PLR effects might be to assess changes not in a surrogate of cardiac output but in the respiratory variation of arterial pulse pressure (PPV) or stroke volume (SVV) in mechanically ventilated patients.”
ResultInfluentialChopra, S., Thompson, J. M., Shahangian, S., Thapamagar, S. B., Moretta, D., Gasho, C., Cohen, A., & Nguyen, H. B. (2019) · PLoS ONE · doi:10.1371/journal.pone.0222956 · Cited by 19 · cited 1×
“However, the repeatability of bioreactance cardiac output measurements during PLR has recently been questioned [22].”
BackgroundNoninvasive Blood Pressure Monitoring and Prediction of Fluid Responsiveness to Passive Leg Raising
Pickett, J. D., Bridges, E. J., Kritek, P., & Whitney, J. D. (2018) · American Journal of Critical Care · doi:10.4037/ajcc2018867 · Cited by 15
Elsayed, A. I., Zaghla, H., Mowafy, H., Fakher, M. A., & Selim, K. A. (2021) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-23875 · Cited by 15 · cited 1×
“Moreover, the diagnostic thresholds differ slightly between the few available studies (Table 2), which in addition expressed the change in PPV either as an absolute value [30, 52, 65]} or as a percent change [56, 66, 67], or both [29].”
BackgroundMa, G., Xu, L., Luo, J., Hou, J., Hao, G., Su, Y., Liu, K., Yu, S.-J., Tu, G.-W., & Luo, Z. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-700 · Cited by 14
Weil, G., Motamed, C., Monnet, X., Eghiaian, A., & Maho, A.-L. L. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004205 · Cited by 14 · cited 1×
“Finally, a study recently suggested that the EEO test loses sensitivity during laparoscopic surgery [58].”
BackgroundSelf-citationAzadian, M., Win, S., Abdipour, A., Kim, C. K., & Nguyen, H. B. (2021) · Journal of Intensive Care Medicine · doi:10.1177/08850666211019713 · Cited by 13 · cited 1×
“A reduction in mortality, which was not the primary goal of these studies, was not observed, as confirmed in two meta-analyses [107, 108].”
ResultDynamic Tests to Predict Fluid Responsiveness After Off-Pump Coronary Artery Bypass Grafting
Fot, E. V., Izotova, N. N., Smetkin, A. A., Владимирович, К. В., & Кirov, М. Y. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.09.013 · Cited by 10 · cited 2×
“Two small studies recently showed that the decrease in PPV and SVV during a 100 mL mini-fluid challenge predicted the response to volume expansion with acceptable reliability [63, 64] (Table 1).”
BackgroundMethodLi, L., Ai, Y., Huang, L., Ai, M., Peng, Q., & Zhang, L. (2020) · Medicine · doi:10.1097/md.0000000000023764 · Cited by 10
Enevoldsen, J., Scheeren, T., Berg, J. M., & Vistisen, S. T. (2021) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13965 · Cited by 7 · cited 1×
“This could have led to an overestimation of the test reliability [85].”
Background
Cited by
2023 Update on Sepsis and Septic Shock in Adult Patients: Management in the Emergency Department
Guarino, M., Perna, B., Cesaro, A. E., Maritati, M., Spampinato, M. D., Contini, C., & De Giorgio, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093188 · Cited by 294
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“The PLR test reproduces the hemodynamic effects of approximately 300 mL of fluid load, while being reversible [45].”
BackgroundMethodSelf-citationA plea for personalization of the hemodynamic management of septic shock
De Backer, D., Cecconi, M., Chew, M. S., Hajjar, L., Monnet, X., Ospina-Tascón, G. A., Ostermann, M., Pinsky, M. R., & Vincent, J.-L. (2022) · Critical Care · doi:10.1186/s13054-022-04255-y · Cited by 177
Self-citationEffective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
Self-citation
Metadata
- Authors
- Monnet, X., Shi, R., & Teboul, J.-L.
- Venue
- Annals of Intensive Care
- Publisher
- Elsevier BV
- Published
- 2022-05-28
- Volume
- 12
- Issue
- 1
- Pages
- 46-46
- ISSN
- 2110-5820 (ISSN-L)
- OpenAlex
- W4281719596
- Cited by
- 249
- References
- 99
- FWCI
- 44.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.