Prediction of fluid responsiveness. What’s new?
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Although the administration of fluid is the first treatment considered in almost all cases of circulatory failure, this therapeutic option poses two essential problems: the increase in cardiac output induced by a bolus of fluid is inconstant, and the deleterious effects of fluid overload are now clearly demonstrated. This is why many tests and indices have been developed to detect preload dependence and predict fluid responsiveness. In this review, we take stock of the data published in the field over the past three years. Regarding the passive leg raising test, we detail the different stroke volume surrogates that have recently been described to measure its effects using minimally invasive and easily accessible methods. We review the limits of the test, especially in patients with intra-abdominal hypertension. Regarding the end-expiratory occlusion test, we also present recent investigations that have sought to measure its effects without an invasive measurement of cardiac output. Although the limits of interpretation of the respiratory variation of pulse pressure and of the diameter of the vena cava during mechanical ventilation are now well known, several recent studies have shown how changes in pulse pressure variation itself during other tests reflect simultaneous changes in cardiac output, allowing these tests to be carried out without its direct measurement. This is particularly the case during the tidal volume challenge, a relatively recent test whose reliability is increasingly well established. The mini-fluid challenge has the advantage of being easy to perform, but it requires direct measurement of cardiac output, like the classic fluid challenge. Initially described with echocardiography, recent studies have investigated other means of judging its effects. We highlight the problem of their precision, which is necessary to evidence small changes in cardiac output. Finally, we point out other tests that have appeared more recently, such as the Trendelenburg manoeuvre, a potentially interesting alternative for patients in the prone position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malbrain, M. L. N. G., Van Regenmortel, N., Saugel, B., De Tavernier, B., Van Gaal, P.-J., Joannes-Boyau, O., Teboul, J.-L., Rice, T. W., Mythen, M., & Monnet, X. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0402-x · Cited by 632 · cited 2×
“This means that many patients will inadvertently receive fluids while there is no cardiac output response [1, 2].”
BackgroundSelf-citationEvans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005357 · Cited by 513 · cited 2×
“In this context, a dynamic measurement of preload responsiveness is recommended, as during sepsis for example [12].”
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482 · cited 4×
“The test not only has good sensitivity and specificity (85 and 91%, respectively) [9], but also very good positive and negative predictive values and likelihood ratios [11].”
BackgroundInfluentialSelf-citationCannesson, M. P., Desebbe, O., Rosamel, P., Delannoy, B., Robin, J., Bastien, O. H., & Lehot, J.-J. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen133 · Cited by 377 · cited 1×
“The respiratory variation of the perfusion index, quantified by the pleth variability index, has been demonstrated to indicate preload responsiveness [25], even though some poorer results have been reported in critically ill patients receiving norepinephrine [26], which may alter the quality of the plethysmographic si…”
ResultMuller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343 · cited 1×
“Therefore, the idea of administering only a “mini-fluid challenge”, performed with a quite small volume of fluid to assess preload responsiveness is interesting [80].”
BackgroundLess invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationMalbrain, M. L. N. G., Langer, T., Annane, D., Gattinoni, L., Elbers, P., Hahn, R. G., De laet, I., Minini, A., Wong, A., Ince, C., et al. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00679-3 · Cited by 323 · cited 1×
“This means that many patients will inadvertently receive fluids while there is no cardiac output response [1, 2].”
BackgroundComparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308 · cited 3×
“A large study confirmed that changes in diameter, especially of the inferior vena cava, have low diagnostic sensitivity and specificity in detecting preload responsiveness, as assessed by the PLR test [72].”
BackgroundMethodInfluentialMonnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Self-citationPassive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289 · cited 1×
“The advantage of this “self-transfusion” of roughly 300 mL of blood [6] is that it is reversible.”
BackgroundSelf-citation
Cited by
2023 Update on Sepsis and Septic Shock in Adult Patients: Management in the Emergency Department
Guarino, M., Perna, B., Cesaro, A. E., Maritati, M., Spampinato, M. D., Contini, C., & De Giorgio, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093188 · Cited by 294
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“The PLR test reproduces the hemodynamic effects of approximately 300 mL of fluid load, while being reversible [45].”
BackgroundMethodSelf-citationA plea for personalization of the hemodynamic management of septic shock
De Backer, D., Cecconi, M., Chew, M. S., Hajjar, L., Monnet, X., Ospina-Tascón, G. A., Ostermann, M., Pinsky, M. R., & Vincent, J.-L. (2022) · Critical Care · doi:10.1186/s13054-022-04255-y · Cited by 177
Self-citationEffective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
Self-citation
Metadata
- Authors
- Monnet, X., Shi, R., & Teboul, J.-L.
- Venue
- Annals of Intensive Care
- Publisher
- Elsevier BV
- Published
- 2022-05-28
- Volume
- 12
- Issue
- 1
- Pages
- 46-46
- ISSN
- 2110-5820 (ISSN-L)
- OpenAlex
- W4281719596
- Cited by
- 249
- References
- 99
- FWCI
- 44.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.