CoChat

Automated image analysis of NSCLC biopsies to predict response to anti-PD-L1 therapy

Open access
Althammer, Sonja, Tan, Tze Heng, Spitzmüller, Andreas, Rognoni, Lorenz, Wiestler, Tobias, Herz, Thomas, Widmaier, Moritz, Rebelatto, Marlon C., Kaplon, Helene, Damotte, Diane, Alifano, Marco, Hammond, Scott A., Dieu-Nosjean, Marie-Caroline, Ranade, Koustubh, Schmidt, Guenter, Higgs, Brandon W., Steele, Keith E. · 2019 · Journal for ImmunoTherapy of Cancer
Cited by 99

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Immune checkpoint therapies (ICTs) targeting the programmed cell death-1 (PD1)/programmed cell death ligand-1 (PD-L1) pathway have improved outcomes for patients with non-small cell lung cancer (NSCLC), particularly those with high PD-L1 expression. However, the predictive value of manual PD-L1 scoring is imperfect and alternative measures are needed. We report an automated image analysis solution to determine the predictive and prognostic values of the product of PD-L1+ cell and CD8+ tumor infiltrating lymphocyte (TIL) densities (CD8xPD-L1 signature) in baseline tumor biopsies. METHODS: Archival or fresh tumor biopsies were analyzed for PD-L1 and CD8 expression by immunohistochemistry. Samples were collected from 163 patients in Study 1108/NCT01693562, a Phase 1/2 trial to evaluate durvalumab across multiple tumor types, including NSCLC, and a separate cohort of 199 non-ICT- patients. Digital images were automatically scored for PD-L1+ and CD8+ cell densities using customized algorithms applied with Developer XD™ 2.7 software. RESULTS: For patients who received durvalumab, median overall survival (OS) was 21.0 months for CD8xPD-L1 signature-positive patients and 7.8 months for signature-negative patients (p = 0.00002). The CD8xPD-L1 signature provided greater stratification of OS than high densities of CD8+ cells, high densities of PD-L1+ cells, or manually assessed tumor cell PD-L1 expression ≥25%. The CD8xPD-L1 signature did not stratify OS in non-ICT patients, although a high density of CD8+ cells was associated with higher median OS (high: 67 months; low: 39.5 months, p = 0.0009) in this group. CONCLUSIONS: An automated CD8xPD-L1 signature may help to identify NSCLC patients with improved response to durvalumab therapy. Our data also support the prognostic value of CD8+ TILS in NSCLC patients who do not receive ICT. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01693562 . Study code: CD-ON-MEDI4736-1108. Interventional study (ongoing but not currently recruiting). Actual study start date: August 29, 2012. Primary completion date: June 23, 2017 (final data collection date for primary outcome measure).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40425-019-0589-x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 99

Metadata

Authors
Althammer, S., Tan, T. H., Spitzmüller, A., Rognoni, L., Wiestler, T., Herz, T., Widmaier, M., Rebelatto, M. C., Kaplon, H., Damotte, D., Alifano, M., Hammond, S. A., Dieu-Nosjean, M.-C., Ranade, K., Schmidt, G., Higgs, B. W., & Steele, K. E.
Venue
Journal for ImmunoTherapy of Cancer
Publisher
BMJ
Published
2019-05-06
Volume
7
Issue
1
Pages
121-121
ISSN
2051-1426 (ISSN-L)
OpenAlex
W2947923969
Cited by
99
References
13
FWCI
5.80
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated image analysis of NSCLC biopsies to predict response to anti-PD-L1 therapy. https://app.cochat.ai/papers/10.1186/s40425-019-0589-x
The paper
Althammer, S., Tan, T. H., Spitzmüller, A., Rognoni, L., Wiestler, T., Herz, T., Widmaier, M., Rebelatto, M. C., Kaplon, H., Damotte, D., Alifano, M., Hammond, S. A., Dieu-Nosjean, M.-C., Ranade, K., Schmidt, G., Higgs, B. W., & Steele, K. E. (2019). Automated image analysis of NSCLC biopsies to predict response to anti-PD-L1 therapy. Journal for ImmunoTherapy of Cancer. https://doi.org/10.1186/s40425-019-0589-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.