Torque differences due to the material variation of the orthodontic appliance: a finite element study
Open accessAbstract
BACKGROUND: Torque of the maxillary incisors is crucial to occlusal relationship and esthetics and can be influenced by many factors. The aim of this study was to assess the relative influence of the material of the orthodontic appliance (adhesive, bracket, ligature, and wire) on tooth displacements and developed stresses/strains after torque application. METHODS: A three-dimensional upper right central incisor with its periodontal ligament (PDL) and alveolus was modeled. A 0.018-in. slot discovery® (Dentaurum, Ispringen, Germany) bracket with a rectangular 0.018 x 0.025-in. wire was generated. The orthodontic appliance varied in the material of its components: adhesive (composite resin or resin-modified glass ionomer cement), bracket (titanium, steel, or ceramic), wire (beta-titanium or steel), and ligature (elastomeric or steel). A total of 24 models were generated, and a palatal root torque of 5° was applied. Afterwards, crown and apex displacement, strains in the PDL, and stresses in the bracket were calculated and analyzed. RESULTS: The labial crown displacement and the palatal root displacement of the tooth were mainly influenced by the material of the wire (up to 150% variation), followed by the material of the bracket (up to 19% variation). The magnitude of strains developed in the PDL was primarily influenced by the material of the wire (up to 127% variation), followed by the material of the bracket (up to 30% variation) and the ligature (up to 13% variation). Finally, stresses developed at the bracket were mainly influenced by the material of the wire (up to 118% variation) and the bracket (up to 59% variation). CONCLUSIONS: The material properties of the orthodontic appliance and all its components should be considered during torque application. However, these in silico results need to be validated in vivo before they can be clinically extrapolated.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Biomechanical differences in applied force magnitude, torque expression, and frictional resistance have been reported between elastomeric and steel ligatures.
“Biomechanically, differences in applied force magnitude, torque expression, and frictional resistance have been reported between elastomeric and steel ligatures [60–62].”
From Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis (2024) · cites this paper as [61]
The Results (Table 3; page unavailable) show differences in tooth displacement and periodontal-ligament strain between elastomeric and steel ligatures after torque application. The Methods describe a fixed bracket–wire friction coefficient, but the paper does not report a comparison of applied force magnitude or frictional resistance between the ligatures. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Materials-induced variation in the torque expression of preadjusted appliances
Gioka, C., & Eliades, T. (2004) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2003.02.007 · Cited by 139 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 37
- [1]O’Higgins EA Kirschen RH Lee RT The influence of maxillary incisor inclination on arch length Br J Orthod 1999 26 97 2 10.1093/ortho/26.2.97 10420243 · DOI
- [3]Sebanc J Brantley WA Pincsak JJ Conover JP Variability of effective torque as a function of edge bevel on orthodontic arch wires Am J Orthod 1984 86 43 51 10.1016/0002-9416(84)90275-6 6588759 · DOI
- [4]Germane N Bentley BE Jr Isaacson RJ Three biologic variables modifying faciolingual tooth angulation by straight-wire appliances Am J Orthod Dentofacial Orthop 1989 96 312 19 10.1016/0889-5406(89)90350-8 2801636 · DOI
- [5]Miethke RR Melsen B Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances Am J Orthod 1999 116 329 35 10.1016/S0889-5406(99)70246-5 10474107 · DOI
- [6]Morina E Eliades T Pandis N Jäger A Bourauel C Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets Eur J Orthod 2008 30 233 38 10.1093/ejo/cjn005 18540011 · DOI
- [7]Archambault A Major TW Carey JP Heo G Badawi H Major PW A comparison of torque expression between stainless steel, titanium molybdenum alloy, and copper nickel titanium wires in metallic self-ligating brackets Angle Orthod 2010 80 884 89 10.2319/102809-604.1 20578859 PMC8939027 · DOI
- [8]Papageorgiou SN Konstantinidis I Papadopoulou K Jäger A Bourauel C Clinical effects of pre-adjusted edgewise orthodontic brackets: a systematic review and meta-analysis Eur J Orthod 2014 36 350 63 10.1093/ejo/cjt064 24062378 · DOI
- [9]Papageorgiou SN Keilig L Hasan I Jäger A Bourauel C Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis Eur J Orthod 2016 38 300 7 10.1093/ejo/cjv050 26174769 PMC4914907 · DOI
- [10]Papageorgiou SN Gölz L Jäger A Eliades T Bourauel C Lingual vs. labial fixed orthodontic appliances: systematic review and meta-analysis of treatment effects Eur J Oral Sci 2016 124 105 18 10.1111/eos.12250 26916846 · DOI
- [11]Turner CH Pavalko FM Mechanotransduction and functional response of the skeleton to physical stress: the mechanisms and mechanics of bone adaptation J Orthop Sci 1998 3 346 55 10.1007/s007760050064 9811988 · DOI
- [12]Melsen B Tissue reaction to orthodontic tooth movement—a new paradigm Eur J Orthod 2001 23 671 81 10.1093/ejo/23.6.671 11890063 · DOI
- [13]Kawarizadeh A Bourauel C Zhang D Götz W Jäger A Correlation of stress and strain profiles and the distribution of osteoclastic cells induced by orthodontic loading in rat Eur J Oral Sci 2004 112 140 47 10.1111/j.1600-0722.2004.00116.x 15056111 · DOI
- [14]Khouw FE Goldhaber P Changes in vasculature of the periodontium associated with tooth movement in the rhesus monkey and dog Arch Oral Biol 1970 15 1125 32 10.1016/0003-9969(70)90003-8 4995399 · DOI
- [15]Quinn RS Yoshikawa DK A reassessment of force magnitude in orthodontics Am J Orthod 1985 88 252 60 10.1016/S0002-9416(85)90220-9 3862348 · DOI
- [16]Kaley J Phillips C Factors related to root resorption in edgewise practice Angle Orthod 1991 61 125 32 2064070
- [17]Weltman B Vig KW Fields HW Shanker S Kaizar EE Root resorption associated with orthodontic tooth movement: a systematic review Am J Orthod Dentofacial Orthop 2010 137 462 76 10.1016/j.ajodo.2009.06.021 20362905 · DOI
- [18]Reimann S Keilig L Jäger A Bourauel C Biomechanical finite-element investigation of the position of the centre of resistance of the upper incisors Eur J Orthod 2007 29 219 24 10.1093/ejo/cjl086 17317864 · DOI
- [19]Kettenbeil A Reimann S Reichert C Keilig L Jäger A Bourauel C Numerical simulation and biomechanical analysis of an orthodontically treated periodontally damaged dentition J Orofac Orthop 2013 74 480 93 10.1007/s00056-013-0182-8 24173364 · DOI
- [20]Viecilli RF Budiman A Burstone CJ Axes of resistance for tooth movement: does the center of resistance exist in 3-dimensional space? Am J Orthod Dentofacial Orthop 2013 143 163 72 10.1016/j.ajodo.2012.09.010 23374922 · DOI
- [21]Tominaga JY Chiang PC Ozaki H Tanaka M Koga Y Bourauel C Yoshida N Effect of play between bracket and archwire on anterior tooth movement in sliding mechanics: a three-dimensional finite element study J Dent Biomech 2012 3 1758736012461269 10.1177/1758736012461269 23115578 PMC3480707 · DOI
- [22]Tominaga JY Ozaki H Chiang PC Sumi M Tanaka M Koga Y Bourauel C Yoshida N Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics: a 3-dimensional finite element study Am J Orthod Dentofacial Orthop 2014 146 166 74 10.1016/j.ajodo.2014.04.016 25085299 · DOI
- [23]Huang Y Keilig L Rahimi A Reimann S Eliades T Jäger A Bourauel C Numeric modeling of torque capabilities of self-ligating and conventional brackets Am J Orthod Dentofacial Orthop 2009 136 638 43 10.1016/j.ajodo.2009.04.018 19892278 · DOI
- [24]Reimann S Keilig L Jäger A Brosh T Shpinko Y Vardimon AD Bourauel C Numerical and clinical study of the biomechanical behaviour of teeth under orthodontic loading using a headgear appliance Med Eng Phys 2009 31 539 46 10.1016/j.medengphy.2008.08.008 19054703 · DOI
- [25]Chatzigianni A Keilig L Duschner H Götz H Eliades T Bourauel C Comparative analysis of numerical and experimental data of orthodontic mini-implants Eur J Orthod 2011 33 468 75 10.1093/ejo/cjr097 21852288 · DOI
- [26]MacGinnis M Chu H Youssef G Wu KW Machado AW Moon W The effects of micro-implant assisted rapid palatal expansion (MARPE) on the nasomaxillary complex—a finite element method (FEM) analysis Prog Orthod 2014 15 52 10.1186/s40510-014-0052-y 25242527 PMC4148550 · DOI
- [27]Jahanbin A Abtahi M Heravi F Hoseini M Shafaee H Analysis of different positions of fiber-reinforced composite retainers versus multistrand wire retainers using the finite element method Int J Biomater 2014 2014 581029 10.1155/2014/581029 25400664 PMC4221902 · DOI
- [28]Papageorgiou SN, Sifakakis I, Keilig L, Patcas R, Affolter S, Eliades T, Bourauel C. Torque differences according to tooth morphology and bracket placement: a finite element study. Eur J Orthod 2016 [Epub ahead of print] 27932407
- [29]Delivanis HP Kuftinec MM Variation in morphology of the maxillary central incisors found in Class II, Division 2 malocclusions Am J Orthod 1980 78 438 43 10.1016/0002-9416(80)90024-X 6933852 · DOI
- [30]Papageorgiou SN Sifakakis I Doulis I Eliades T Bourauel C Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets Prog Orthod 2016 17 5 10.1186/s40510-016-0118-0 26780465 PMC4715034 · DOI
- [31]Horiuchi A Hotokezaka H Kobayashi K Correlation between cortical plate proximity and apical root resorption Am J Orthod Dentofacial Orthop 1998 114 311 8 10.1016/S0889-5406(98)70214-8 9743137 · DOI
- [32]Gracco A Lombardo L Mancuso G Gravina V Siciliani G Upper incisor position and bony support in untreated patients as seen on CBCT Angle Orthod 2009 79 692 02 10.2319/081908-437.1 19537878 · DOI
- [33]Harris EF Hassankiadeh S Harris JT Maxillary incisor crown-root relationships in different angle malocclusions Am J Orthod Dentofacial Orthop 1993 103 48 53 10.1016/0889-5406(93)70104-V 8422031 · DOI
- [34]Ziegler A Keilig L Kawarizadeh A Jäger A Bourauel C Numerical simulation of the biomechanical behaviour of multi-rooted teeth Eur J Orthod 2005 27 333 9 10.1093/ejo/cji020 15961572 · DOI
- [35]Dong-Xu L Hong-Ning W Chun-Ling W Hong L Ping S Xiao Y Modulus of elasticity of human periodontal ligament by optical measurement and numerical simulation Angle Orthod 2011 81 229 36 10.2319/060710-311.1 21208074 PMC8925269 · DOI
- [36]Johnson G Walker MP Kula K Fracture strength of ceramic bracket tie wings subjected to tension Angle Orthod 2005 75 95 100 15747822
- [37]Zinelis S Annousaki O Eliades T Makou M Elemental composition of brazing alloys in metallic orthodontic brackets Angle Orthod 2004 74 394 99 15264653
- [38]Joch A Pichelmayer M Weiland F Bracket slot and archwire dimensions: manufacturing precision and third order clearance J Orthod 2010 37 241 49 10.1179/14653121043182 21186304 · DOI
Cited by
Sorted by citations
Hussain, U., Campobasso, A., Noman, M., Alam, S., Mujeeb, R., Shehzad, S., & Papageorgiou, S. N. (2024) · Progress in Orthodontics · doi:10.1186/s40510-024-00520-8 · Cited by 13 · see citing works
Self-citation
- Authors
- Papageorgiou, S. N., Keilig, L., Vandevska-Radunovic, V., Eliades, T., & Bourauel, C.
- Affiliations
- University of Zurich (CH)
- University of Bonn (DE)
- Corresponding author
- Papageorgiou, Spyridon N.
- Venue
- Progress in Orthodontics
- Published
- 2017-02-27
- Volume
- 18
- Issue
- 1
- Pages
- 6-6
- ISSN
- 1723-7785 (ISSN-L)
- 2196-1042
- PMC
- PMC5326743
- OpenAlex
- W2584965956
- Cited by
- 33
- References
- 1
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 8 · 2023: 5 · 2022: 1 · 2021: 6 · 2020: 2 · 2019: 1 · 2018: 4
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Progress in Orthodontics (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- Forschungsgemeinschaft Dental (FGD) (N/A)
- Topics
- Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
- Health Sciences › Dentistry › Orthodontics › Dental materials and restorations
- Health Sciences › Health Professions › Emergency Medical Services › Dental Trauma and Treatments
- Keywords
- maxillary incisors, bracket material, beta-titanium wire, composite resin adhesive, resin-modified glass ionomer cement, elastomeric ligatures, tooth displacement, finite element analysis
- MeSH terms
- Alveolar Process, Models, Dental, Dental Stress Analysis, Humans, Incisor, Orthodontic Appliances, Orthodontic Wires, Periodontal Ligament, Orthodontic Brackets, Torque, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review