CoChat

Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis

Open access

The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index; 13 of the 49 sources its claims cite were checked for support.

Abstract

INTRODUCTION: Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health. AIM: This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances. METHODS: Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach. RESULTS: A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias. CONCLUSIONS: Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load. REGISTRATION: PROSPERO (CRD42023444383).

Overview

CoChat Summary

TL;DR

This systematic review and meta-analysis found low-certainty evidence that elastomeric and stainless steel ligatures do not meaningfully differ in periodontal outcomes during fixed appliance orthodontic treatment. Elastomeric ligatures were associated with a moderate increase in total bacterial load, but not with clear differences in plaque, gingival inflammation, probing pocket depth, or *Streptococcus mutans* counts.

Key findings

  • The review included 11 studies (3 randomized, 8 non-randomized) with 354 patients; mean age was 14.7 years and 42% male.
  • No statistically significant differences were found for:
  • Plaque index: 5 studies; SMD = 0.48; 95% CI -0.03 to 1.00; P = 0.07
  • Gingival index: 2 studies; MD = 0.01; 95% CI -0.14 to 0.16; P = 0.89
  • Probing pocket depth: 2 studies; MD = 0; 95% CI -0.17 to 0.16; P = 0.97
  • *Streptococcus mutans* counts: 4 studies; SMD = 0.40; 95% CI -0.41 to 1.20; P = 0.21
  • Elastomeric ligatures were associated with a moderately increased total bacterial load: 3 studies; SMD = 0.43; 95% CI 0.10 to 0.76; P = 0.03.
  • The authors note this translates to elastomeric ligatures having on average 0.30 × 10^5 CFU/ml greater bacterial counts than steel ligatures.

Methods

  • Systematic review and meta-analysis of human comparative clinical studies on fixed labial appliances ligated with elastomeric vs stainless steel ligatures; registered in PROSPERO (CRD42023444383) and reported per PRISMA 2020.
  • Searched 7 databases up to July 2023 without restrictions on year, language, or publication type; also screened references and Google Scholar related articles.
  • Used duplicate screening/extraction, RoB 2 for randomized trials, ROBINS-I for non-randomized studies, and random-effects meta-analysis with MD/SMD plus GRADE certainty assessment.

Limitations

  • The paper explicitly states the evidence was low quality / low certainty because it included non-randomized studies with high risk of bias.
  • It also states that the meta-analyses were based on few studies with very limited sample sizes, which could bias results.
  • Evident from the text: several outcomes were informed by only 2–5 studies, and all included randomized trials were judged high risk of bias while all non-randomized studies were at least seriously biased.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s40510-024-00520-8

Cites

69 of 69 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Flowdiagram for the identification and selection of studies for this review
Fig. 1 Flowdiagram for the identification and selection of studies for this reviewCC BY · PubMed Central
Fig. 2 Meta-analysis comparing plaque index between fixed appliances ligated with elastomeric and stainless steel ligatures. CI, confidence interval; N number of patients; QH Quigley Hein index; RE random-effects model; SD standard deviation; SiLo Silness & Löe index; SMD standardized mean difference
Fig. 2 Meta-analysis comparing plaque index between fixed appliances ligated with elastomeric and stainless steel ligatures. CI, confidence interval; N number of patients; QH Quigley Hein index; RE random-effects model; SD standard deviation; SiLo Silness & Löe index; SMD standardized mean differenceCC BY · PubMed Central
Fig. 3 Meta-analysis comparing gingival index between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; MD mean difference; N number of patients; RE random-effects model; SD standard deviation
Fig. 3 Meta-analysis comparing gingival index between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; MD mean difference; N number of patients; RE random-effects model; SD standard deviationCC BY · PubMed Central
Fig. 4 Meta-analysis comparing pocket probing depth between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; MD mean difference; N number of patients; RE random-effects model; SD standard deviation
Fig. 4 Meta-analysis comparing pocket probing depth between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; MD mean difference; N number of patients; RE random-effects model; SD standard deviationCC BY · PubMed Central
Fig. 5 Meta-analysis comparing bacterial counts between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; N number of patients; RE random-effects model; SD standard deviation; SMD standardized mean difference
Fig. 5 Meta-analysis comparing bacterial counts between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; N number of patients; RE random-effects model; SD standard deviation; SMD standardized mean differenceCC BY · PubMed Central
Fig. 6 Meta-analysis comparing salivary Streptococcus mutans counts between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; N number of patients; RE random-effects model; SD standard deviation; SMD standardized mean difference
Fig. 6 Meta-analysis comparing salivary Streptococcus mutans counts between fixed appliances ligated with elastomeric and stainless steel ligatures. CI confidence interval; N number of patients; RE random-effects model; SD standard deviation; SMD standardized mean differenceCC BY · PubMed Central

Verification

Claims the paper makes

10 Valid · 1 Not valid · 12 Not checked · 30 Own results and interpretations

15 more claims

Create a free account to see all 53 claims and to verify the 4 references still open.

See all claims — free account
  • It may state two separate claims as one. 27
  • Probably not a substantial claim. 17

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 69 references

Research works printed but not linked: 1

  1. Shalchi M, Hajian-Tilaki A, khanjani MS, Sabzgolin P, Aghajani Nargesi R. Comparing Streptococcus Mutans adhesion by using different Orthodontic Bracket ligations: an in Vitro Study. J Dentomaxillofac Radiol Pathol Surg. 2018;7(1):7–12.

Cited by

See all 13

Metadata

Authors
Hussain, U., Campobasso, A., Noman, M., Alam, S., Mujeeb, R., Shehzad, S., & Papageorgiou, S. N.
Affiliations
  • Saidu College of Dentistry (PK)
  • University of Foggia (IT)
  • Government of Khyber Pakhtunkhwa (PK)
  • Fatima Memorial Hospital (PK)
  • Gandhara University (PK)
  • University of Zurich (CH)
Corresponding author
Papageorgiou, Spyridon N.
Venue
Progress in Orthodontics
Published
2024-06-17
Volume
25
Issue
1
Pages
24-24
ISSN
  • 1723-7785 (ISSN-L)
  • 2196-1042
OpenAlex
W4399757274
Cited by
13
References
69
Citations by year
2026: 4 · 2025: 8 · 2024: 1
FWCI
1.37
Type
journal article
Language
en
Open access
Licence
Locations
  • Progress in Orthodontics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
Topics
  • Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
  • Health Sciences › Dentistry › Periodontics › Oral microbiology and periodontitis research
  • Health Sciences › Dentistry › General Dentistry › Dental Research and COVID-19
Keywords
elastomeric ligatures, fixed orthodontic appliances, periodontal health, plaque index, gingival index, probing depth, Streptococcus mutans, microbial colonization, orthodontic patients, adolescents and young adults, gingivitis, periodontal risk factors, orthodontic treatment duration
MeSH terms
Orthodontic Appliances, Fixed, Humans, Ligation, Periodontal Index, Steel, Orthodontic Brackets, Elastomers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s40510-024-00520-8
The paper
Hussain, U., Campobasso, A., Noman, M., Alam, S., Mujeeb, R., Shehzad, S., & Papageorgiou, S. N. (2024). Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis. Progress in Orthodontics. https://doi.org/10.1186/s40510-024-00520-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.