In vitro comparison of the adsorption of inflammatory mediators by blood purification devices

Open access
Malard, Benjamin, Lambert, Corine, Kellum, John A.·2018·Intensive Care Medicine Experimental

Abstract

BACKGROUND: Septic shock, a leading cause of acute kidney injury, induces release of pro-/anti-inflammatory mediators, leading to increased mortality and poor renal recovery. This is the first in vitro study directly comparing three single-use blood purification devices in terms of removing sepsis-associated mediators and endotoxins. METHODS: . Heparinized human plasma from healthy volunteers was pre-incubated with pathologic quantities of inflammatory mediators and filtered in a closed-loop circulation model for 2 h. For each device, the removal of 27 inflammatory mediators was measured over time. Endotoxin removal mediated by oXiris and Toraymyxin was assessed using hemoperfusion over 6 h. RESULTS: Endotoxin (lipopolysaccharide) removal was most rapid with Toraymyxin; mean adsorptive clearance over the first 30 min was ~ 20 ml/min vs ~ 8 ml/min with oXiris (p < 0.05). There was minimal endotoxin removal with CytoSorb (1 ml/min). At 120 min, there was no significant difference between the endotoxin removal rates using oXiris (mean ± standard deviation, 68.0 ± 4.4%) and Toraymyxin (83.4 ± 3.8%); both were significantly higher vs CytoSorb (- 6.3 ± 4.9%; p < 0.05). Total removal with oXiris was 6.9 μg vs 9.7 μg for Toraymyxin, where the total lipopolysaccharide quantity introduced was approximately 15.8 μg. Removal rates of pro-/anti-inflammatory cytokines and other inflammatory mediators were similar between oXiris and CytoSorb and were higher with CytoSorb and oXiris vs Toraymyxin. Granulocyte colony-stimulating factor was only effectively adsorbed by CytoSorb (99.4%). Differences were detected between the adsorption mechanism of the devices; binding to oXiris was mainly ionic, while CytoSorb was hydrophobic. No specific protein adsorption was found qualitatively with Toraymyxin. CONCLUSIONS: Adsorption rate kinetics varied for individual inflammatory mediators using the three blood purification devices. Mechanisms of adsorption differed between the devices. oXiris was the only device tested that showed both endotoxin and cytokine removal. oXiris showed similar endotoxin adsorption to Toraymyxin and similar adsorption to CytoSorb for the removal of other inflammatory mediators. Differences in device removal capacities could enable treatment to be more tailored to patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40635-018-0177-2

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 273

Metadata

Authors
Malard, B., Lambert, C., & Kellum, J. A.
Venue
Intensive Care Medicine Experimental
Published
2018-05-04
Volume
6
Issue
1
Pages
12-12
ISSN
2197-425X (ISSN-L)
OpenAlex
W2806162835
Cited by
273
References
21
FWCI
18.07
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro comparison of the adsorption of inflammatory mediators by blood purification devices. https://app.cochat.ai/papers/10.1186/s40635-018-0177-2
The paper
Malard, B., Lambert, C., & Kellum, J. A. (2018). In vitro comparison of the adsorption of inflammatory mediators by blood purification devices. Intensive Care Medicine Experimental. https://doi.org/10.1186/s40635-018-0177-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.