Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules
Open accessAbstract
OBJECTIVES: Investigate the effect of a novel Bayesian penalised likelihood (BPL) reconstruction algorithm on analysis of pulmonary nodules examined with 18F-FDG PET/CT, and to determine its effect on small, sub-10-mm nodules. METHODS: 18F-FDG PET/CTs performed for nodule evaluation in 104 patients (121 nodules) were retrospectively reconstructed using the new algorithm, and compared to time-of-flight ordered subset expectation maximisation (OSEM) reconstruction. Nodule and background parameters were analysed semi-quantitatively and visually. RESULTS: BPL compared to OSEM resulted in statistically significant increases in nodule SUVmax (mean 5.3 to 8.1, p < 0.00001), signal-to-background (mean 3.6 to 5.3, p < 0.00001) and signal-to-noise (mean 24 to 41, p < 0.00001). Mean percentage increase in SUVmax (%ΔSUVmax) was significantly higher in nodules ≤10 mm (n = 31, mean 73%) compared to >10 mm (n = 90, mean 42 %) (p = 0.025). Increase in signal-to-noise was higher in nodules ≤10 mm (224%, mean 12 to 27) compared to >10 mm (165%, mean 28 to 46). When applying optimum SUVmax thresholds for detecting malignancy, the sensitivity and accuracy increased using BPL, with the greatest improvements in nodules ≤10 mm. CONCLUSION: BPL results in a significant increase in signal-to-background and signal-to-noise compared to OSEM. When semi-quantitative analyses to diagnose malignancy are applied, higher SUVmax thresholds may be warranted owing to the SUVmax increase compared to OSEM. KEY POINTS: • Novel Bayesian penalised likelihood PET reconstruction was applied for lung nodule evaluation. • This was compared to current standard of care OSEM reconstruction. • The novel reconstruction generated significant increases in lung nodule signal-to-background and signal-to-noise. • These increases were highest in small, sub-10-mm pulmonary nodules. • Higher SUV max thresholds may be warranted when using semi-quantitative analyses to diagnose malignancy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
PL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF.
“PL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF [112,113,164,173,174].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [173]
The Results (Visual analysis of FDG uptake; Diagnostic performance, page unavailable) show higher nodule signal and modestly higher sensitivity with penalised-likelihood reconstruction than with time-of-flight OSEM. However, the Methods (PET reconstructions) and Discussion show that this study did not compare against OSEM with PSF modelling. The Results also found no statistically significant difference in ROC performance, so the claim of improved detection needs qualification. (LLM, conf=0.88)
Experimental — accuracy not yet measuredTeoh et al. retrospectively investigated diagnostic accuracy of OSEM + TOF and PL reconstruction using SUVmax and visual reading in 121 pulmonary nodules with histological verification; diagnostic sensitivity and accuracy were similar with both algorithms, while specificity tended to be lower with PL than with OSEM + TOF, especially in lesions >10 mm diameter.
“As an exception, Teoh et al. retrospectively investigated the diagnostic accuracy of OSEM + TOF and PL reconstruction using SUVmax and visual reading in 121 pulmonary nodules. Here, histological verification was available. Diagnostic sensitivity and accuracy were similar with both algorithms, while specificity tended to be lower with PL than with OSEM + TOF, especially in lesions >10 mm diameter [”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [173]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 22
- [1]Gould MK Maclean CC Kuschner WG Rydzak CE Owens DK Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: a meta-analysis JAMA 2001 285 914 924 10.1001/jama.285.7.914 11180735 · DOI
- [2]Fletcher JW Kymes SM Gould M A comparison of the diagnostic accuracy of 18F-FDG PET and CT in the characterization of solitary pulmonary nodules J Nucl Med 2008 49 179 185 10.2967/jnumed.107.044990 18199626 · DOI
- [3]van Tinteren H Hoekstra OS Smit EF Effectiveness of positron emission tomography in the preoperative assessment of patients with suspected non-small-cell lung cancer: the PLUS multicentre randomised trial Lancet 2002 359 1388 1393 10.1016/S0140-6736(02)08352-6 11978336 · DOI
- [4]Maffione AM Grassetto G Rampin L Molecular imaging of pulmonary nodules AJR Am J Roentgenol 2014 202 W217 W223 10.2214/AJR.13.11733 24555617 · DOI
- [5]Khalaf M, Abdel-Nabi H, Baker J, Shao Y, Lamonica D, Gona J (2008) Relation between nodule size and 18F-FDG-PET SUV for malignant and benign pulmonary nodules. J Hematol Oncol 1:13-8722-1-13 PMC2563015 18808716
- [6]Kim SK Allen-Auerbach M Goldin J Accuracy of PET/CT in characterization of solitary pulmonary lesions J Nucl Med 2007 48 214 220 17268017
- [7]Nomori H, Watanabe K, Ohtsuka T, Naruke T, Suemasu K, Uno K (2005) Visual and semiquantitative analyses for F-18 fluorodeoxyglucose PET scanning in pulmonary nodules 1 cm to 3 cm in size. Ann Thorac Surg 79:984–988 15734419
- [8]Adams MC Turkington TG Wilson JM Wong TZ A systematic review of the factors affecting accuracy of SUV measurements AJR Am J Roentgenol 2010 195 310 320 10.2214/AJR.10.4923 20651185 · DOI · Paper page
- [9]Kinahan PE Fletcher JW Positron emission tomography-computed tomography standardized uptake values in clinical practice and assessing response to therapy Semin Ultrasound CT MR 2010 31 496 505 10.1053/j.sult.2010.10.001 21147377 PMC3026294 · DOI · Paper page
- [10]Tong S Alessio AM Kinahan PE Image reconstruction for PET/CT scanners: past achievements and future challenges Imaging Med 2010 2 529 545 10.2217/iim.10.49 21339831 PMC3039307 · DOI
- [11]Alessio AM Stearns CW Tong S Application and evaluation of a measured spatially variant system model for PET image reconstruction IEEE Trans Med Imaging 2010 29 938 949 10.1109/TMI.2010.2040188 20199927 PMC2903538 · DOI
- [12]Lasnon C Hicks RJ Beauregard JM Impact of point spread function reconstruction on thoracic lymph node staging with 18F-FDG PET/CT in non-small cell lung cancer Clin Nucl Med 2012 37 971 976 10.1097/RLU.0b013e318251e3d1 22899197 · DOI
- [13]Bettinardi V Presotto L Rapisarda E Picchio M Gianolli L Gilardi MC Physical performance of the new hybrid PETCT discovery-690 Med Phys 2011 38 5394 5411 10.1118/1.3635220 21992359 · DOI
- [14]Hudson HM Larkin RS Accelerated image reconstruction using ordered subsets of projection data IEEE Trans Med Imaging 1994 13 601 609 10.1109/42.363108 18218538 · DOI
- [17]Mumcuoglu EU Leahy RM Cherry SR Bayesian reconstruction of PET images: methodology and performance analysis Phys Med Biol 1996 41 1777 1807 10.1088/0031-9155/41/9/015 8884912 · DOI
- [18]Nuyts J Beque D Dupont P Mortelmans L A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomography IEEE Trans Nucl Sci 2002 49 56 60 10.1109/TNS.2002.998681 · DOI
- [19]Asma E, Ahn S, Ross SG, Chen A, Manjeshwar RM (2012) Accurate and consistent lesion quantitation with clinically acceptable penalized likelihood images. Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE:4062–4066
- [20]Ahn S Fessler JA Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms IEEE Trans Med Imaging 2003 22 613 626 10.1109/TMI.2003.812251 12846430 · DOI
- [21]Hanley JA McNeil BJ A method of comparing the areas under receiver operating characteristic curves derived from the same cases Radiology 1983 148 839 843 10.1148/radiology.148.3.6878708 6878708 · DOI · Paper page
- [22]Rahmim A Qi J Sossi V Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls Med Phys 2013 40 064301 10.1118/1.4800806 23718620 PMC3663852 · DOI
- [23]Herder GJ Golding RP Hoekstra OS The performance of (18)F-fluorodeoxyglucose positron emission tomography in small solitary pulmonary nodules Eur J Nucl Med Mol Imaging 2004 31 1231 1236 10.1007/s00259-004-1552-7 15175835 · DOI
- [24]Kwee TC Cheng G Lam MG Basu S Alavi A SUVmax of 2.5 should not be embraced as a magic threshold for separating benign from malignant lesions Eur J Nucl Med Mol Imaging 2013 40 1475 1477 10.1007/s00259-013-2484-x 23801170 · DOI
Cited by
Sorted by citations
Teoh, E. J., McGowan, D. R., Macpherson, R. E., Bradley, K. M., & Gleeson, F. V. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159301 · Cited by 265 · see citing works
Self-citationLindström, E., Sundin, A., Trampal, C., Lindsjö, L., Ilan, E., Danfors, T., Antoni, G., Sörensen, J., & Lubberink, M. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200790 · Cited by 99 · see citing works
Howard, B. A., Morgan, R., Thorpe, M. P., Turkington, T. G., Oldan, J., James, O. G., & Borges-Neto, S. (2017) · Annals of Nuclear Medicine · doi:10.1007/s12149-017-1192-1 · Cited by 70 · see citing works
Reynés‐Llompart, G., Gámez‐Cenzano, C., Vercher‐Conejero, J. L., Sabaté‐Llobera, A., Calvo‐Malvar, N., & Martí‐Climent, J. M. (2018) · Medical Physics · doi:10.1002/mp.12986 · Cited by 55 · see citing works
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 50 · see citing works
Lindström, E., Velikyan, I., Regula, N., Alhuseinalkhudhur, A., Sundin, A., Sörensen, J., & Lubberink, M. (2019) · Theranostics · doi:10.7150/thno.31970 · Cited by 32 · see citing works
Kurita, Y., Ichikawa, Y., Nakanishi, T., Tomita, Y., Hasegawa, D., Murashima, S., Hirano, T., & Sakuma, H. (2020) · Annals of Nuclear Medicine · doi:10.1007/s12149-020-01446-x · Cited by 29 · see citing works
Wu, Z., Qin, Z., Huang, B., Guo, B., Hao, X., Wu, P., Zhao, B., Xie, J., & Li, S. (2020) · doi:10.21203/rs.3.rs-17003/v1 · Cited by 2 · see citing works
- Authors
- Teoh, E. J., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., & Gleeson, F. V.
- Affiliations
- Churchill Hospital (GB)
- John Radcliffe Hospital (GB)
- Corresponding author
- Teoh, Eugene J.
- Venue
- European Radiology
- Published
- 2015-05-20
- Volume
- 26
- Issue
- 2
- Pages
- 576-584
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- PMC
- PMC4551414
- OpenAlex
- W1540985874
- Cited by
- 109
- References
- 0
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 2 · 2023: 10 · 2022: 11 · 2021: 20 · 2020: 16 · 2019: 12 · 2018: 7 · 2017: 8 · 2016: 9 · 2015: 2 · 2012: 1
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- European Radiology (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
- Funders
- Cancer Research UK (16466)
- National Institute for Health and Care Research (NIHR-HCS-D12-03-13)
- NIHR Oxford Biomedical Research Centre
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- PET image reconstruction, pulmonary nodules, small pulmonary nodules, 18F-FDG PET/CT, SUVmax, signal-to-background ratio, signal-to-noise ratio, OSEM comparison, SUVmax threshold
- MeSH terms
- Adult, Aged, Aged, 80 and over, Algorithms, Bayes Theorem, Solitary Pulmonary Nodule, Female, Humans, Image Processing, Computer-Assisted, Lung, Lung Neoplasms, Male, Middle Aged, Retrospective Studies, Tomography, X-Ray Computed, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography, Young Adult, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review