The influence of surface texture and wettability on initial bacterial adhesion on titanium and zirconium oxide dental implants
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
This study aims to investigate bacterial adhesion on different titanium and ceramic implant surfaces, to correlate these findings with surface roughness and surface hydrophobicity, and to define the predominant factor for bacterial adhesion for each material. Zirconia and titanium specimens with different surface textures and wettability (5.0 mm in diameter, 1.0 mm in height) were prepared. Surface roughness was measured by perthometer (R a ) and atomic force microscopy, and hydrophobicity according to contact angles by computerized image analysis. Bacterial suspensions of Streptococcus sanguinis and Staphylococcus epidermidis were incubated for 2 h at 37 °C with ten test specimens for each material group and quantified with fluorescence dye CytoX-Violet and an automated multi-detection reader. Variations in surface roughness (R a ) did not lead to any differences in adhering S. epidermidis, but higher R a resulted in increased S. sanguinis adhesion. In contrast, higher bacterial adhesion was observed on hydrophobic surfaces than on hydrophilic surfaces for S. epidermidis but not for S. sanguinis. The potential to adhere S. sanguinis was significantly higher on ceramic surfaces than on titanium surfaces; no such preference could be found for S. epidermidis. Both surface roughness and wettability may influence the adhesion properties of bacteria on biomaterials; in this context, the predominant factor is dependent on the bacterial species. Wettability was the predominant factor for S. epidermidis and surface texture for S. sanguinis. Zirconia did not show any lower bacterial colonization potential than titanium. Arithmetical mean roughness values R a (measured by stylus profilometer) are inadequate for describing surface roughness with regard to its potential influence on microbial adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dewhirst, F. E., Chen, T., Izard, J., Paster, B. J., Tanner, A. C. R., Yu, W.-H., Lakshmanan, A., & Wade, W. G. (2010) · Journal of Bacteriology · doi:10.1128/jb.00542-10 · Cited by 3,352
Zirconia as a ceramic biomaterial
Piconi, C., & Maccauro, G. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00010-6 · Cited by 2,806
Effect of material characteristics and/or surface topography on biofilm development
Teughels, W., Van Assche, N., Sliepen, I., & Quirynen, M. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01353.x · Cited by 1,358 · cited 4×
“AFM, which was developed to obtain fine details of a surface on a molecular scale, was found to be the most suitable instrument for surface roughness measurements [11, 26].”
BackgroundMethodInfluentialConcise review of mechanisms of bacterial adhesion to biomaterial surfaces
An, Y. H., & Friedman, R. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199823)43:3<338::aid-jbm16>3.0.co;2-b · Cited by 1,146 · cited 2×
“surface modifications with reduced adhesion properties or even with antibacterial properties are of pertinent clinical interest [13, 14].”
BackgroundAlbrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Quirynen, M., & Bollen, C. M. L. (1995) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1995.tb01765.x · Cited by 1,037 · cited 2×
“Surface roughness itself is known to influence hydrophobicity [51], but many studies have also clearly shown that minor variations in surface roughness do not significantly affect hydrophobicity values [12].”
BackgroundInfectious risks for oral implants: a review of the literature
Quirynen, M., De Soete, M., & Van Steenberghe, D. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130101.x · Cited by 665 · cited 1×
“5 μm in diameter) on smooth zirconia surfaces in AFM may possibly explain the enhanced potential to adhere bacteria in contrast to totally plane titanium surfaces, because initial microbial colonization has been shown to start from very small—and not from large-scale—pits and gullies [25, 26, 38, 39].”
BackgroundThe influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070302.x · Cited by 661 · cited 1×
“2 μm; below this threshold, a change in roughness did not significantly affect the quantity of plaque accumulation [27, 37].”
BackgroundBacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study
Scarano, A., Piattelli, M., Caputi, S., Favero, G. A., & Piattelli, A. (2004) · Journal of Periodontology · doi:10.1902/jop.2004.75.2.292 · Cited by 622 · cited 4×
“In general, the physico-chemical surface properties of an implant—influenced by the type of material, its surface morphology, and surface coatings—define the potential to adhere oral microorganisms [4, 10, 11].”
BackgroundInfluentialPoon, C. Y., & Bhushan, B. (1995) · Wear · doi:10.1016/0043-1648(95)06697-7 · Cited by 576
Cited by
Sharma, S., Mohler, J., Mahajan, S. D., Schwartz, S. A., Bruggemann, L., & Aalinkeel, R. (2023) · Microorganisms · doi:10.3390/microorganisms11061614 · Cited by 993
Zheng, S., Bawazir, M., Dhall, A., Kim, H.-E., He, L., Heo, J., & Hwang, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.643722 · Cited by 872
Bacterial anti-adhesion surface design: Surface patterning, roughness and wettability: A review
Yang, K., Shi, J., Wang, L., Chen, Y., Liang, C., Yang, L., & Wang, L.-N. (2022) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.05.028 · Cited by 330
Apostu, D., Lucaciu, O., Berce, C., Lucaciu, D., & Cosma, D. (2018) · Journal of International Medical Research · doi:10.1177/0300060517732697 · Cited by 236
“Studies have reported an increase in Staphylococcus epidermidis with increased implant wettability and in Streptococcus sanguinis when a more porous surface is used.(44) As soon as bacteria colonize the titanium implant, they form a complex of microbial cells contained in an extracellular matrix, called biofilm.”
Laser Surface Texturing of Polymers for Biomedical Applications
Riveiro, A., Maçon, A. L. B., del Val, J., Comesaña, R., & Pou, J. (2018) · Frontiers in Physics · doi:10.3389/fphy.2018.00016 · Cited by 236
Bioadhesion in the oral cavity and approaches for biofilm management by surface modifications
Sterzenbach, T., Helbig, R., Hannig, C., & Hannig, M. (2020) · Clinical Oral Investigations · doi:10.1007/s00784-020-03646-1 · Cited by 212
How microbes read the map: Effects of implant topography on bacterial adhesion and biofilm formation
Lee, S. W., Phillips, K. S., Gu, H., Kazemzadeh-Narbat, M., & Ren, D. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120595 · Cited by 198
Metadata
- Authors
- Wassmann, T., Kreis, S., Behr, M., & Buergers, R.
- Venue
- International Journal of Implant Dentistry
- Published
- 2017-07-17
- Volume
- 3
- Issue
- 1
- Pages
- 32-32
- ISSN
- 2198-4034 (ISSN-L)
- OpenAlex
- W2734888830
- Cited by
- 252
- References
- 56
- FWCI
- 20.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.