The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Intraoperative optical coherence tomographic findings in patients undergoing subretinal gene therapy surgery
Open accessAbstract
Background: To analyze intraoperative OCT (iOCT) findings during subretinal gene therapy. Methods: A single-center, retrospective, observational, case series study of twenty one eyes submitted to subretinal gene therapy. Intrasurgical high definition videos were included for analyzes. Cases with absence of iOCT video or unsuccessful bleb creation were excluded. Sharp needle tip (SNT) or blunted needle tip (BNT) and their interaction with neurosensory retina were evaluated. Presence of subretinal air bubbles, visible opened retinotomy, and medication reflux were also correlated and analyzed. Results: Nineteen of twenty-one eyes were included. Of the two excluded eyes, subretinal bleb creation was unsuccessful in one and technical issues prevented OCT image acquisition in the other. Immediately before subretinal injection, needle indention/penetration of the neurosensory retina with temporary indentation of the RPE/choroid was evident in 16 (84%) of the 19 eyes. Complete RPE/choroid indentation was needed with BNT use compared to SNT (p = 0.0114). An open retinotomy was identified in 14 (74%) of 19 eyes at the conclusion of bleb injection and was more commonly associated with SNT (p = 0.0108). Conclusions: iOCT provides valuable real-time feedback of cross-sectional retinal anatomy during subretinal gene therapy surgeries. The type of needle tip and its use during the gene therapy procedure seems to influence in the bleb creation and presence of visible open retinotomy. Further studies of iOCT findings during gene therapy delivery procedures are likely to help refine the surgical technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“there are still practical limitations in iOCT systems including restricted OCT fields, shadowing of the operative site by intravitreal instruments and the inability for surgeons to operate and observe the iOCT image in real time.”
From Subretinal therapy: technological solutions to surgical and immunological challenges (2022) · cites this paper as [17]
Experimental — accuracy not yet measuredIn the citing paper
“The needle-penetration step has a narrow margin of error: excessively deep penetration of the needle tip can result in hemorrhage, cannula tip obstruction, unintentional suprachoroidal delivery of vector, or permanent RPE injury; however, too shallow needle penetration can create retinoschisis by intraretinal hydration during bleb formation.97”
From Current clinical applications of in vivo gene therapy with AAVs (2021) · cites this paper as [97]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Safety and Efficacy of Gene Transfer for Leber's Congenital Amaurosis
Maguire, A. M., Simonelli, F., Pierce, E. A., Pugh, E. N., Mingozzi, F., Bennicelli, J., Banfi, S., Marshall, K. A., Testa, F., Surace, E. M., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802315 · Cited by 2,145
Russell, S., Bennett, J., Wellman, J. A., Chung, D. C., Yu, Z.-F., Tillman, A., Wittes, J., Pappas, J., Elci, O., McCague, S., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31868-8 · Cited by 1,952
Effect of gene therapy on visual function in Leber’s congenital amaurosis
Bainbridge, J. W. B., Smith, A. J., Barker, S. S., Robbie, S., Henderson, R., Balaggan, K., Viswanathan, A., Holder, G. E., Stockman, A., Tyler, N., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802268 · Cited by 1,924
Hauswirth, W. W., Aleman, T. S., Kaushal, S., Cideciyan, A. V., Schwartz, S. B., Wang, L., Conlon, T. J., Boye, S. L., Flotte, T. R., Byrne, B. J., et al. (2008) · Human Gene Therapy · doi:10.1089/hum.2008.107 · Cited by 954
MacLaren, R. E., Groppe, M., Barnard, A. R., Cottriall, C. L., Tolmachova, T., Seymour, L., Clark, K. R., During, M. J., Cremers, F. P. M., Black, G. C. M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62117-0 · Cited by 796
Iron-Overload–Related Disease in HFE Hereditary Hemochromatosis
Allen, K. J., Gurrin, L. C., Constantine, C. C., Osborne, N. J., Delatycki, M. B., Nicoll, A. J., McLaren, C. E., Bahlo, M., Nisselle, A. E., Vulpe, C. D., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa073286 · Cited by 731
Ghazi, N. G., Abboud, E. B., Nowilaty, S. R., Alkuraya, H., Alhommadi, A., Cai, H., Hou, R., Deng, W.-T., Boye, S. L., Almaghamsi, A., et al. (2016) · Human Genetics · doi:10.1007/s00439-016-1637-y · Cited by 243
Technique of retinal gene therapy: delivery of viral vector into the subretinal space
Xue, K., Groppe, M., Salvetti, A. P., & MacLaren, R. E. (2017) · Eye · doi:10.1038/eye.2017.158 · Cited by 191
Lentiviral Vector Gene Transfer of Endostatin/Angiostatin for Macular Degeneration (GEM) Study
Campochiaro, P. A., Lauer, A. K., Sohn, E. H., Mir, T. A., Naylor, S., Anderton, M. C., Kelleher, M., Harrop, R., Ellis, S., & Mitrophanous, K. A. (2017) · Human Gene Therapy · doi:10.1089/hum.2016.117 · Cited by 186
Self-citationSubretinal injection: a review on the novel route of therapeutic delivery for vitreoretinal diseases
Peng, Y., Tang, L., & Zhou, Y. (2017) · Ophthalmic Research · doi:10.1159/000479157 · Cited by 175
Cited by
Current clinical applications of in vivo gene therapy with AAVs
Mendell, J. R., Al-Zaidy, S. A., Rodino-Klapac, L. R., Goodspeed, K., Gray, S. J., Kay, C. N., Boye, S. L., Boye, S. E., George, L. A., Salabarria, S., et al. (2021) · Molecular Therapy · doi:10.1016/j.ymthe.2020.12.007 · Cited by 743
“The needle-penetration step has a narrow margin of error: excessively deep penetration of the needle tip can result in hemorrhage, cannula tip obstruction, unintentional suprachoroidal delivery of vector, or permanent RPE injury; however, too shallow needle penetration can create retinoschisis by intraretinal hydratio…”
BackgroundSubretinal injection techniques for retinal disease: A review
Irigoyen, C., Amenabar Alonso, A., Sanchez-Molina, J., Rodríguez-Hidalgo, M., Lara-López, A., & Ruiz-Ederra, J. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11164717 · Cited by 106
Gene Therapy in Inherited Retinal Diseases: An Update on Current State of the Art
Amato, A., Arrigo, A., Aragona, E., Manitto, M. P., Saladino, A., Bandello, F. M., & Parodi, M. B. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.750586 · Cited by 77
“With respect to SRI, vitreoretinal subspecialists have reported the utility of in vivo real-time monitor of the surgical act through integrated optical coherence tomography (OCT) operating microscope (33).”
BackgroundSubretinal therapy: technological solutions to surgical and immunological challenges
Ladha, R., Caspers, L. E., Willermain, F., & de Smet, M. D. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.846782 · Cited by 54
Clinical applications for intraoperative optical coherence tomography: a systematic review
Muijzer, M. B., Schellekens, P. A. W. J. F., Beckers, H. J. M., de Boer, J. H., Imhof, S. M., & Wisse, R. P. L. (2021) · Eye · doi:10.1038/s41433-021-01686-9 · Cited by 53
Metadata
- Authors
- Vasconcelos, H. M., Lujan, B. J., Pennesi, M. E., Yang, P., & Lauer, A. K.
- Affiliations
- Oregon Health & Science University (US)
- Corresponding author
- Lauer, Andreas K.
- Venue
- International Journal of Retina and Vitreous
- Published
- 2020-05-01
- Volume
- 6
- Issue
- 1
- Pages
- 13-13
- ISSN
- 2056-9920 (ISSN-L)
- PMC
- PMC7193395
- OpenAlex
- W3021610408
- Cited by
- 39
- References
- 30
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 7 · 2020: 3
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- International Journal of Retina and Vitreous (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- GOAP
- National Institutes of Health (K08EY026650)
- Foundation Fighting Blindness (NMT-0714-648)
- Unrestricted Grant from Research to Prevent Blindness
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Keywords
- intraoperative optical coherence tomography, subretinal gene therapy, subretinal injection, needle tip design, retinotomy, surgical technique
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative optical coherence tomographic findings in patients undergoing subretinal gene therapy surgery. https://app.cochat.ai/papers/10.1186/s40942-020-00216-1
- The paper
- Vasconcelos, H. M., Lujan, B. J., Pennesi, M. E., Yang, P., & Lauer, A. K. (2020). Intraoperative optical coherence tomographic findings in patients undergoing subretinal gene therapy surgery. International Journal of Retina and Vitreous. https://doi.org/10.1186/s40942-020-00216-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.