The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Review of additive manufactured tissue engineering scaffolds: relationship between geometry and performance
Open accessAbstract
Material extrusion additive manufacturing has rapidly grown in use for tissue engineering research since its adoption in the year 2000. It has enabled researchers to produce scaffolds with intricate porous geometries that were not feasible with traditional manufacturing processes. Researchers can control the structural geometry through a wide range of customisable printing parameters and design choices including material, print path, temperature, and many other process parameters. Currently, the impact of these choices is not fully understood. This review focuses on how the position and orientation of extruded filaments, which sometimes referred to as the print path, lay-down pattern, or simply “scaffold design”, affect scaffold properties and biological performance. By analysing trends across multiple studies, new understanding was developed on how filament position affects mechanical properties. Biological performance was also found to be affected by filament position, but a lack of consensus between studies indicates a need for further research and understanding. In most research studies, scaffold design was dictated by capabilities of additive manufacturing software rather than free-form design of structural geometry optimised for biological requirements. There is scope for much greater application of engineering innovation to additive manufacture novel geometries. To achieve this, better understanding of biological requirements is needed to enable the effective specification of ideal scaffold geometries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 1×
“3 to 20 MPa for cartilage [40, 41], 100 to 500 MPa for cancellous bone [42], and 12,000 to 20,000 MPa for cortical bone [42, 43].”
Background
Cited by
Printability–A key issue in extrusion-based bioprinting
Naghieh, S., & Chen, X. (2021) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2021.02.001 · Cited by 270
Baptista, R., & Guedes, M. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111528 · Cited by 157
Ehtesabi, H., & Massah, F. (2021) · Materials Today Sustainability · doi:10.1016/j.mtsust.2021.100075 · Cited by 70
Metadata
- Authors
- Gleadall, A., Visscher, D., Yang, J., Thomas, D., & Segal, J.
- Venue
- Burns & Trauma
- Publisher
- Oxford University Press (OUP)
- Published
- 2018
- Volume
- 6
- Pages
- 19-19
- ISSN
- 2321-3868 (ISSN-L)
- 2321-3876
- OpenAlex
- W2808934756
- Cited by
- 172
- References
- 1
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of additive manufactured tissue engineering scaffolds: relationship between geometry and performance. https://app.cochat.ai/papers/10.1186/s41038-018-0121-4
- The paper
- Gleadall, A., Visscher, D., Yang, J., Thomas, D., & Segal, J. (2018). Review of additive manufactured tissue engineering scaffolds: relationship between geometry and performance. Burns & Trauma. https://doi.org/10.1186/s41038-018-0121-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.