A digital twin framework for improving energy efficiency and occupant comfort in public and commercial buildings
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Model Predictive Control (MPC) can be used in the context of building automation to improve energy efficiency and occupant comfort. Ideally, the MPC algorithm should consider current- and planned usage of the controlled environment along with initial state and weather forecast to plan for optimal comfort and energy efficiency. This implies the need for an MPC application which 1) considers multiple objectives, 2) can draw on multiple data sources, and 3) provides an approach to effectively integrate against heterogeneous building automation systems to make the approach reusable across different installations. To this end, this paper presents a design and implementation of a framework for digital twins for buildings in which the controlled environments are represented as digital entities. In this framework, digital twins constitute parametrized models which are integrated into a generic control algorithm that uses data on weather forecasts, current- and planned occupancy as well as the current state of the controlled environment to perform MPC. This data is accessed through a generic data layer to enable uniform data access. This enables the framework to switch seamlessly between simulation and real-life applications and reduces the barrier towards reusing the application in a different control environment. We demonstrate an application of the digital twin framework on a case study at the University of Southern Denmark where a digital twin has been used to control heating and ventilation. From the case study, we observe that we can switch from rule-based control to model predictive control with no immediate adverse effects towards comfort or energy consumption. We also identify the potential for an increase in energy efficiency, as well as introduce the possibility of planning energy consumption against local electricity production or market conditions, while maintaining occupant comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Across the reviewed real-world studies, reliability, explainability, and real-time feasibility are more frequently emphasized than theoretical optimality [116,117,125].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [116]
In the citing paper
“others implemented adaptive or occupant-centered models based on feedback or estimated thermal sensation [101,116].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [116]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cao, X., Dai, X., & Liu, J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.06.089 · Cited by 1,436
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
Self-citation
Research works printed but not linked: 27
- Al-Ghaili AM, Kasim H, Al-Hada NM, Jørgensen BN, Othman M, Jihua W (2021) Energy Management Systems and Strategies in Buildings Sector: A Scoping Review. IEEE Access 9:63790–63813 · DOI
- Arendt K, Clausen A, Mattera CG, Jradi M, Johansen A, Veje C et al (2019) Multi-objective model predictive control framework for buildings. In: Procedings of the 16th IBPSA international conference and exhibition building simulation 2019, pp 822–829
- Arendt K, Jradi M, Shaker HR, Veje C. Comparative analysis of white-, gray-and black-box models for thermal simulation of indoor environment: Teaching building case study. In Proceedings of the 2018 Building Performance Modeling Conference and SimBuild co-organized by ASHRAE and IBPSA-USA, Chicago 2018a. p. 26–28.
- Arendt K, Jradi M, Wetter M, Veje CT (2018b) ModestPy: An Open-Source Python Tool for Parameter Estimation in Functional Mock-up Units. In: Proceedings of The American Modelica Conference 2018, October 9–10, Somberg Conference Center, Cambridge MA, USA. Linköping University Electronic Press, Linköpings universitet, pp 121–130
- Bianchini G, Casini M, Vicino A, Zarrilli D (2016) Demand-response in building heating systems: A Model Predictive Control approach. Appl Energy 168:159–170 · DOI · Paper page
- Billanes JD, Ma Z, Jørgensen BN (2017) Consumer Central Energy Flexibility in Office Buildings. J Energ Power Eng 11 · DOI
- Billanes JD, Ma Z, Jørgensen BN (2018) The Bright Green Hospitals Case Studies of Hospitals’ Energy Efficiency And Flexibility in Philippines. In: 2018 8th International Conference on Power and Energy Systems (ICPES), pp 190–195 · DOI
- Clausen A, Umair A, Demazeau Y, Jørgensen BN (2020a) Impact of Social Welfare Metrics on Energy Allocation in Multi-Objective Optimization. Energies. 13 · DOI
- Dawson-Haggerty S, Jiang X, Tolle G, Ortiz J, Culler D (2010) sMAP: A Simple Measurement and Actuation Profile for Physical Information. In: Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems. Association for Computing Machinery, New York, pp 197–210 · DOI · Paper page
- Dawson-Haggerty S, Krioukov A, Taneja J, Karandikar S, Fierro G, Kitaev N et al (2013) BOSS: Building Operating System Services. In: 10th USENIX Symposium on Networked Systems Design and Implementation (NSDI 13). USENIX Association, Lombard, pp 443–457
- De Coninck R, Helsen L (2016a) Practical implementation and evaluation of model predictive control for an office building in Brussels. Ener Build:290–298 · DOI · Paper page
- Dong B, Lam KP (2014) A real-time model predictive control for building heating and cooling systems based on the occupancy behavior pattern detection and local weather forecasting. Build Simul:89–106 · DOI · Paper page
- Garcia CE, Prett DM, Morari M (1989a) Model predictive control: Theory and practice—A survey. Automatica:335–348 · DOI · Paper page
- Jørgensen BN, Kjærgaard MB, Lazarova-Molnar S, Shaker HR, Veje CT (2015) Challenge: Advancing Energy Informatics to Enable Assessable Improvements of Energy Performance in Buildings. Association for Computing Machinery, New York, pp 77–82
- Jradi M, Sangogboye FC, Mattera CG, Kjærgaard MB, Veje C, Jørgensen BN (2017a) A world class energy efficient university building by danish 2020 standards. Energy Procedia 132:21–26 · doi:10.1016/j.egypro.2017.09.625
- Jradi M, Veje C, Jørgensen BN (2017b) Deep energy renovation of the Mærsk office building in Denmark using a holistic design approach. Ener Build 151:306–319 · DOI
- Kjærgaard MB, Arendt K, Clausen A, Johansen A, Jradi M, Jørgensen BN et al (2016a) Demand response in commercial buildings with an Assessable impact on occupant comfort. In: 2016 IEEE International Conference on Smart Grid Communications (SmartGridComm), pp 447–452 · doi:10.1109/smartgridcomm.2016.7778802
- Kjærgaard MB, Johansen A, Sangogboye F, Holmegaard E (2016b) Occure: an occupancy reasoning platform for occupancy-driven applications. In: 2016 19th International ACM SIGSOFT Symposium on Component-Based Software Engineering (CBSE), pp 39–48 · DOI
- Lazarova-Molnar S, Kjærgaard MB, Shaker HR, Jørgensen BN (2015) Commercial buildings energy performance within context occupants in spotlight. In: 2015 International Conference on Smart Cities and Green ICT Systems (SMARTGREENS), pp 1–7
- Leitner SH, Mahnke W (2006) OPC UA–service-oriented architecture for industrial applications. ABB Corp Res Center 48:61–66
- Li X, Malkawi A (2016a) Multi-objective optimization for thermal mass model predictive control in small and medium size commercial buildings under summer weather conditions. Energy:1194–1206 · DOI
- Ma Z, Badi A, Jørgensen BN (2016) Market opportunities and barriers for smart buildings. In: 2016 IEEE Green Energy and Systems Conference (IGSEC), pp 1–6
- Ma Z, Billanes JD, Jørgensen BN (2017b) Aggregation Potentials for Buildings—Business Models of Demand Response and Virtual Power Plants. Energies. 10 · DOI
- Ma Z, Dalmacio Billanes J, Kjærgaard MB, Jorgensen BN (2017a) Energy flexibility in retail buildings: From a business ecosystem perspective. In: 2017 14th International Conference on the European Energy Market (EEM), pp 1–6
- Marler RT, Arora JS (2004) Survey of multi-objective optimization methods for engineering. Struct Multidiscip Optim 26:369–395 · DOI · Paper page
- Sangogboye FC, Arendt K, Singh A, Veje CT, Kjærgaard MB, Jørgensen BN (2017) Performance comparison of occupancy count estimation and prediction with common versus dedicated sensors for building model predictive control. In: Building Simulation, pp 829–843
- Sørensen JC, Jørgensen BN (2017) An extensible component-based multi-objective evolutionary algorithm framework. In: Proceedings of the 6th International Conference on Software and Computer Applications, pp 191–197 · doi:10.1145/3056662.3056690
Cited by
Arowoiya, V. A., Moehler, R. C., & Fang, Y. (2024) · Energy and Built Environment · doi:10.1016/j.enbenv.2023.05.004 · Cited by 195
Digital Twins’ Applications for Building Energy Efficiency: A Review
Bortolini, R., Rodrigues, R., Alavi, H., Vecchia, L. F. D., & Forcada, N. (2022) · Energies · doi:10.3390/en15197002 · Cited by 189
Analysis of Digital Twin Applications in Energy Efficiency: A Systematic Review
Ba, L., Tangour, F., El Abbassi, I., & Absi, R. (2025) · Sustainability · doi:10.3390/su17083560 · Cited by 153
A review of drivers and barriers of Digital Twin adoption in building project development processes
Jahangir, M. F., Schultz, C. P. L., & Kamari, A. (2024) · Journal of Information Technology in Construction · doi:10.36680/j.itcon.2024.008 · Cited by 34
Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications
Michailidis, P., Minelli, F., Michailidis, I., Kurucan, M., Coban, H. H., & Kosmatopoulos, E. (2025) · Energies · doi:10.3390/en19010219 · Cited by 26
Metadata
- Authors
- Clausen, A., Arendt, K., Johansen, A., Sangogboye, F. C., Kjærgaard, M. B., Veje, C. T., & Jørgensen, B. N.
- Venue
- Energy Informatics
- Published
- 2021-09
- Volume
- 4
- Issue
- S2
- ISSN
- 2520-8942
- Cited by
- 134
- References
- 2
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor, 23 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A digital twin framework for improving energy efficiency and occupant comfort in public and commercial buildings. https://app.cochat.ai/papers/10.1186/s42162-021-00153-9
- The paper
- Clausen, A., Arendt, K., Johansen, A., Sangogboye, F. C., Kjærgaard, M. B., Veje, C. T., & Jørgensen, B. N. (2021). A digital twin framework for improving energy efficiency and occupant comfort in public and commercial buildings. Energy Informatics. https://doi.org/10.1186/s42162-021-00153-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.