Auditory fatigue among call center operators with headset
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: To assess whether call center operators are subject to or suffer from any auditory fatigue when compared to normal subjects. A prospective case-control study where twenty-eight call center operators (10 females and 18 males) with an age range from 25 to 46 years and twenty controls (12 females and 8 males) with an age range from 23 to 44 years were included. All call center operators use a headset for up to 8 h daily for a minimum of two consecutive years. Audiological assessments were done to all participants that included pure tone audiometry (PTA), speech audiometry, tympanometry, and acoustic reflexes. Moreover, transient-evoked otoacoustic emission (TEOAE) absolute threshold and distortion product otoacoustic emission (DPOAE) signal to noise thresholds as well as contralateral suppression of TEOAEs and DPOAEs were recorded for both groups. Results: There was no significant variation in auditory performances detected with either PTA or OAE (TEOAEs and DPOAEs) test. Besides, there was no statistically significant difference in OAEs (TEOAEs and DPOAEs) with contralateral suppression for both the call center operators and control groups. However, call center operators expressed a feeling of tiredness. Conclusions: There was no detectable central or peripheral auditory fatigue experienced by the call center operators when using headsets. However, their sensation of auditory fatigue could be due to cognitive fatigue rather than noise-induced fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Adults (≥ 18 years): Eight studies [3, 77, 97, 11, 81, 61, 89, 70] with a total of 1,324 participants in the PLD user group and 577 in the non-user group showed a pooled OR of 2.43 (95% CI: 1.21–4.87; p = 0.01; I²=64%). This was statistically significant”
From Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis (2026) · cites this paper as [81]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Syka, J. (2002) · Physiological Reviews · doi:10.1152/physrev.00002.2002 · Cited by 369 · cited 1×
“by the OAEs consists of the physiological function of inner hair cells, afferent fibers, the olivocochlear complex, the efferent fibers, and the middle-ear muscles reflex threshold [5, 6, 16].”
Background
Research works printed but not linked: 21
- Liberman MC, Dodds LW (1987) Acute ultrastructural changes in acoustic trauma: serial- section reconstruction of stereocilia and cuticular plates. Hear Res. 26(1):45–64 · DOI
- Westcott M (2006) Acoustic shock injury (ASI). Acta Otolaryngol. 126:54–58 · DOI
- Beyan A, Demiral Y, Cimrin A, Ergor A (2016) Call centers and noise-induced hearing loss. Noise Health. 18(81):113–116 · doi:10.4103/1463-1741.178512
- Trompette N, Chatillon J (2012) Survey of noise exposure and background noise in call centers using headphones. J Occup Environ Hyg. 9(6):381–386 · doi:10.1080/15459624.2012.680852
- Finlayson PG, Kaltenbach JA (2009) Alterations in the spontaneous discharge patterns of single units in the dorsal cochlear nucleus following intense sound exposure. Hear Res. 256(1–2):104–117 · DOI
- Venet T, Campo P, Rumeau C, Thomas A, Parietti-Winkler C (2014) One-day measurement to assess the auditory risks encountered by noise-exposed workers. Int J Audiol. 53(10):737–744 · DOI
- Warr WB, Guinan JJ Jr (1979) Efferent innervation of the organ of corti: two separate systems. Brain Res. 173:152–155 · DOI · Paper page
- Warr WB, Guinan JJ, White JS (1986) Organization of the efferent fibres: the lateral and medial olivocochlear systems. In: Hoffman DW, Bobbin RP (eds) Altschuler R.A. The Cochlea. Raven Press; New York, Neurobiology of Hearing, pp 333–348
- Liberman MC (1988) Response properties of cochlear efferent neurons: monaural vs. binaural stimulation and the effects of noise. J Neurophysiol. 60:1779–1798 · doi:10.1152/jn.1988.60.5.1779
- Collet L, Kemp DT, Veuillet E, Duclaux R, Moulin A, Morgon A (1990) Effects of contralateral auditory stimuli on active cochlear micro-mechanical properties in human subjects. Hear Res. 43:251–261 · DOI · Paper page
- Hood LJ, Berlin CI, Hurley A, Cecola RP, Bell B (1996) Contralateral suppression of transient-evoked otoacoustic emissions in humans: intensity effects. Hear Res. 101:113–118 · DOI
- Garinis AC, Glattke T, Cone-Wesson BK (2008) TEOAE suppression in adults with learning disabilities. Int J Audiol. 47:607–614 · doi:10.1080/14992020802129402
- Geven LI, Wit HP, de Kleine E, van Dijk P (2012) Wavelet analysis demonstrates no abnormality in contralateral suppression of otoacoustic emissions in tinnitus patients. Hear Res. 286:30–40 · doi:10.1016/j.heares.2012.02.008
- Maxon AA, White K, Vohr B, Behrans T (1993) Using transient evoked otoacoustic emission for neonatal hearing screening. Br. J. Audiol 27:149–153 · doi:10.3109/03005369309077906
- Atchariyasathian V, Chayarpham S, Saekhow S (2008) Evaluation of noise-induced hearing loss with audiometer and distortion product otoacoustic emissions. J Med Assoc Thail. 91:1066–1071
- Kumar P, Grover V, Publius A S, Sanju HK, Sinha S (2016) Assessment of rock musician’s efferent system functioning using contralateral suppression of otoacoustic emissions. World Journal of Otorhinolaryngology - Head and Neck Surgery · DOI
- Eldredge DH, Covell WP, Gannon RP (1959) Acoustic trauma following intermittent exposure to tones. Ann Otol Rhinol Laryngol. 68:723–732 · doi:10.1177/000348945906800309
- Miller JD, Watson CS, Covell WP (1963) Deafening effects of noise on the cat. Acta Otolaryngol Suppl. 176:1–91
- Kujawa SG, Liberman MC (1999) Long-term sound conditioning enhances cochlear sensitivity. J Neurophysiol. 82:863–873 · DOI
- Mellor D, Moore KA, Siong ZMB (2015) The role of general and specific stressors in the health and well-being of call centre operators. Work. 52:31–43 · DOI
- Lewig KA, Dollard MF (2003) Emotional dissonance, emotional exhaustion and job satisfaction in call centre workers. Eur J Work Organ Psychol. 12(4):366–392 · DOI · Paper page
Cited by
Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis
Golshaniniya, P., PorkarKhatibi, M., Rouhi, A. J., Moghaddam, Y. J., Zabet, S., Salehi-Pourmehr, H., & Shahsavarinia, K. (2026) · BMC Public Health · doi:10.1186/s12889-026-29110-5
Metadata
- Authors
- Afifi, P. O., Abdel Rahman, T. T. T., & Khafagy, A. G.
- Venue
- The Egyptian Journal of Otolaryngology
- Published
- 2020-10-27
- Volume
- 36
- Issue
- 1
- ISSN
- 1012-5574
- 2090-8539
- Cited by
- 4
- References
- 1
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auditory fatigue among call center operators with headset. https://app.cochat.ai/papers/10.1186/s43163-020-00044-y
- The paper
- Afifi, P. O., Abdel Rahman, T. T. T., & Khafagy, A. G. (2020). Auditory fatigue among call center operators with headset. The Egyptian Journal of Otolaryngology. https://doi.org/10.1186/s43163-020-00044-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.