The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Reliability of gait speed measured by a timed walking test in patients one year after stroke
Abstract
Objective: To assess the reliability of gait speed in late-stage stroke patients. Design: Test–retest reliability of three timed walks to 10 metres repeated during two assessments one week apart. Setting: The patient's home. Subjects: Twenty-two stroke patients with mobility problems more than one year after stroke. Main outcome measure: Gait speed measured in seconds taken to walk 10 metres. Statistical analysis: Intraclass correlations (ICCs) with 95% con”dence interval (CI) and the Bland and Altman method for assessing agreement by calculating the mean difference between measurements ( d–); the 95% CI for d–; the standard deviation of the difference (SD diff); a reliability coef”cient and the 95% limits of agreement. Results: There was a trend for decreased times taken to walk 10 metres both within each assessment and between assessments. ICCs for within assessment reliability were 0.95–0.99. The d– (SD diff) for the second and third walks for assessment 1 was –1.00 (2.63) seconds and for assessment 2 was –0.70 (1.58) seconds. The reliability coef”cient was 5.26 for assessment 1 and 3.17 for assessment 2. ICCs for between-assessment reliability were 0.87–0.88. The d – (SD diff) for the comparison of the third walks at assessment 1 and assessment 2 was –0.90 (5.01) seconds. The reliability coef”cient was 10.02 and the 95% limits of agreement were –10.92 to +9.12 seconds. Conclusion: Within-assessment gait speed measured at home is highly reliable. The between-assessment reliability of gait speed measurement is less reliable but comparable with other studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Cited by
RELIABILITY OF GAIT PERFORMANCE TESTS IN MEN AND WOMEN WITH HEMIPARESIS AFTER STROKE
Lexell, J., Flansbjer, U.-B., Holmbäck, A. M., Downham, D., & Patten, C. (2005) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410017215 · Cited by 1,242
Steffen, T., & Seney, M. (2008) · Physical Therapy · doi:10.2522/ptj.20070214 · Cited by 860
Improvements in Speed-Based Gait Classifications Are Meaningful
Schmid, A., Duncan, P. W., Studenski, S., Lai, S. M., Richards, L., Perera, S., & Wu, S. S. (2007) · Stroke · doi:10.1161/strokeaha.106.475921 · Cited by 654
Peters, D. M., Fritz, S. L., & Krotish, D. E. (2013) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e318248e20d · Cited by 646
Beaudart, C., Rolland, Y., Cruz-Jentoft, A. J., Bauer, J. M., Sieber, C., Cooper, C., Al-Daghri, N., Araujo de Carvalho, I., Bautmans, I., Bernabei, R., et al. (2019) · Calcified Tissue International · doi:10.1007/s00223-019-00545-w · Cited by 528
Metadata
- Authors
- Green, J., Forster, A., & Young, J.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 2002-05
- Volume
- 16
- Issue
- 3
- Pages
- 306-314
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2119116126
- Cited by
- 164
- References
- 3
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of gait speed measured by a timed walking test in patients one year after stroke. https://app.cochat.ai/papers/10.1191/0269215502cr495oa
- The paper
- Green, J., Forster, A., & Young, J. (2002). Reliability of gait speed measured by a timed walking test in patients one year after stroke. Clinical Rehabilitation. https://doi.org/10.1191/0269215502cr495oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.