Fluctuations in levels of antiphospholipid antibodies and increased coagulation activation markers in normal andheparin-treated antiphospholipid syndrome pregnancies
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Antiphospholipidantibodies (aPL) are associated with anincreased risk of thrombosis and recurrent miscarriage. Weassessed levels of coagulation activation markers and aPL during normal pregnancy and in women with the antiphospholipid syndrome (aPS). Fluctuations in aPL levels were observed in all patients with aPS. No particular pattern of antibody positivity, or fluctuation in aPL level,was associated with poor pregnancy outcome. A significant increase was observed in levels of factor XIIa(FXIIa; P 0.001), factor VIIa (FVIIa, P 0.001), thrombin antithrombin complexes (TAT; P 0.001), prothrombin fragment F1.2 (F1.2; P 0.001) and D-dimer (DD; P 0.05) during normalpregnancy. Factor VIIa, TAT, F1.2 and DD increased significantly before 20 weeks gestation, while a statistically significant increase in FXIIa levels was first detected between weeks 20 and 30 of gestation. In pregnant women with aPS, increases in FXIIa were similar to those in normal pregnancy, but increasedFVIIa levels were not observed until after 30 weeks gestation.Similar to normal pregnancy, increased levels of TATandF1.2 were detected in aPS pregnancies before 20 weeks gestation, but increased DD were not observed until afterweek 20. Surprisingly, women with aPS receiving low molecular weight heparin prophylaxis had significantly higher (P 0.02) levels of TAT (median 8.6; interquartile range (IQR) 6.5–20.8) between weeks 20 and 30 of gestation compared to the normal pregnant population (median 5.9; IQR 4.7–7.9), thus indicating increased thrombin generationin women with aPS in mid-pregnancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The management of thrombosis in the antiphospholipid-antibody syndrome
Khamashta, M. A., Cuadrado, M. J., Mujic, F., Taub, N. A., Hunt, B. J., & Hughes, G. R. V. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321504 · Cited by 1,450
Rai, R., Cohen, H., Dave, M., & Regan, L. (1997) · BMJ · doi:10.1136/bmj.314.7076.253 · Cited by 1,113
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationAntiphospholipid Antibodies and venous thromboembolism
Ginsberg, J., Wells, P., Brill-Edwards, P., Donovan, D., Moffatt, K., Johnston, M., Stevens, P., & Hirsh, J. (1995) · Blood · doi:10.1182/blood.v86.10.3685.bloodjournal86103685 · Cited by 365
Marked variation in antiphospholipid antibodies during pregnancy: relationships to pregnancy outcome
Topping, J. (1999) · Human Reproduction · doi:10.1093/humrep/14.1.224 · Cited by 57
Cited by
Haemostatic changes in pregnancy
Bremme, K. A. (2003) · Best Practice & Research Clinical Haematology · doi:10.1016/s1521-6926(03)00021-5 · Cited by 869
Thornton, P., & Douglas, J. (2010) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2009.11.010 · Cited by 187
Erez, O., Novack, L., Beer-Weisel, R., Dukler, D., Press, F., Zlotnik, A., Than, N. G., Tomer, A., & Mazor, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093240 · Cited by 146
“In addition, systemic changes are observed in the maternal plasma including : 1) increased concentrations of clotting factors VII, VIII, IX, X and XII [3,9–13] and fibrinogen; 2) a reduction in the concentration of anticoagulant proteins such as protein S and tissue factor pathway inhibitor (TFPI)-1 [14–18]; 3) acquir…”
BackgroundSciascia, S., Cuadrado, M. J., Sanna, G., Murru, V., Roccatello, D., Khamashta, M. A., & Bertolaccini, M. L. (2014) · Arthritis Care & Research · doi:10.1002/acr.22388 · Cited by 55
Yelnik, C. M., Porter, T. F., Branch, D. W., Laskin, C. A., Merrill, J. T., Guerra, M. M., Lockshin, M. D., Buyon, J. P., Petri, M., Sammaritano, L. R., et al. (2016) · Arthritis & Rheumatology · doi:10.1002/art.39668 · Cited by 54
“Lynch et al and Donohoe et al found no relationship between changes in aPL titers and adverse pregnancy outcomes (12,13), while others reported favorable pregnancy outcomes associated with declining titers of aPL (10,11,14).”
Metadata
- Authors
- Donohoe, S., Quenby, S., Mackie, I., Panal, G., Farquharson, R., Malia, R., Kingdom, J., & Machin, S.
- Venue
- Lupus
- Publisher
- SAGE Publications
- Published
- 2002-01
- Volume
- 11
- Issue
- 1
- Pages
- 11-20
- ISSN
- 0961-2033 (ISSN-L)
- 1477-0962
- OpenAlex
- W2039454583
- Cited by
- 40
- References
- 5
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluctuations in levels of antiphospholipid antibodies and increased coagulation activation markers in normal andheparin-treated antiphospholipid syndrome pregnancies. https://app.cochat.ai/papers/10.1191/0961203302lu132oa
- The paper
- Donohoe, S., Quenby, S., Mackie, I., Panal, G., Farquharson, R., Malia, R., Kingdom, J., & Machin, S. (2002). Fluctuations in levels of antiphospholipid antibodies and increased coagulation activation markers in normal andheparin-treated antiphospholipid syndrome pregnancies. Lupus. https://doi.org/10.1191/0961203302lu132oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.