Detection of Antibodies to dsDNA: An Overview of Laboratory Assays
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This brief review is focused on different methodologies available for detection of anti-dsDNA antibodies with respect to the best adequacy between biological results of laboratory and clinical significance. A large array of assays has been developed for the measurement of anti-dsDNA. New assays continually introduced have reflected not only technical innovations to avoid difficulties of some assays, but even more with hope to correlate better with systemic lupus erythematosus (SLE), particularly with its clinical course and exacerbations. Finally, with the development of micro arrays technology new insights into the pathophysiology of autoimmune disease processes should be revealed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The advantage of this assay is that it mainly detects the high avidity antibodies to dsDNA as dsDNA/low avidity dsDNA antibody complexes are dissociated by the high salt conditions [40].”
From Laboratory evaluation of anti-dsDNA antibodies. (2022) · cites this paper as [40]
In the citing paper
“It should be noted that IgMs (and rarely IgAs) are also detected by Farr (no use of secondary antibodies) [40].”
From Laboratory evaluation of anti-dsDNA antibodies. (2022) · cites this paper as [40]
In the citing paper
“Farr-RIA is considered the golden standard because it detects high avidity anti-dsDNA antibodies, but its use in clinical laboratories is rapidly declining as it relies on the use of radioactive reagents.”
From Laboratory evaluation of anti-dsDNA antibodies. (2022) · cites this paper as [40]
In the citing paper
“Detecting anti-dsDNA autoantibodies by enzyme-linked immune sorbent assay (ELISA) has been frequently used in clinical routine because of its ease of use, quantitative results and its high sensitivity compared to CLIFT [40], [49].”
From Laboratory evaluation of anti-dsDNA antibodies. (2022) · cites this paper as [40]
In the citing paper
“Moreover, ELISA is cheap, fast and easily automated [40], [49].”
From Laboratory evaluation of anti-dsDNA antibodies. (2022) · cites this paper as [40]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The 1982 revised criteria for the classification of systemic lupus erythematosus
Tan, E. M., Cohen, A. S., Fries, J. F., Masi, A. T., Mcshane, D. J., Rothfield, N. F., Schaller, J. G., Talal, N., & Winchester, R. J. (1982) · Arthritis & Rheumatism · doi:10.1002/art.1780251101 · Cited by 14,519
Antinuclear Antibodies: Diagnostic Markers for Autoimmune Diseases and Probes for Cell Biology
Tan, E. M. (1989) · Advances in Immunology · doi:10.1016/s0065-2776(08)60641-0 · Cited by 1,514
Advanced multiplexed analysis with the FlowMetrix system.
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · PubMed · Cited by 704
Hahn, B. H. (1998) · New England Journal of Medicine · doi:10.1056/nejm199805073381906 · Cited by 682
Advanced multiplexed analysis with the FlowMetrixTM system
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1749 · Cited by 650
Ter Borg, E. J., Horst, G., Hummel, E. J., Limburg, P. C., & Kallenberg, C. G. M. (1990) · Arthritis & Rheumatism · doi:10.1002/art.1780330505 · Cited by 572
Aarden, L. A., Groot, E. R. D., & Feltkamp, T. E. W. (1975) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1975.tb29197.x · Cited by 563
Evidence‐based guidelines for the use of immunologic tests: Antinuclear antibody testing
Solomon, D. H., Kavanaugh, A. J., Schur, P. H., & American College of Rheumatology Ad Hoc Committee on Immunologic Testing Guidelines (2002) · Arthritis Care & Research · doi:10.1002/art.10561 · Cited by 510
The use of laboratory tests in the diagnosis of SLE
Egner, W. (2000) · Journal of Clinical Pathology · doi:10.1136/jcp.53.6.424 · Cited by 316
Anti‐dsdna and complement profiles as prognostic guides in systemic lupus erythematosus
Swaak, A. J. G., Aarden, L. A., Statius Eps, L. W. V., & Feltkamp, T. E. W. (1979) · Arthritis & Rheumatism · doi:10.1002/art.1780220304 · Cited by 284
Research works printed but not linked: 5
- Servais G, 2001, Scand J Clin Lab Invest, 235, 61
- Tan EM, 2002, J Rheumatol, 29, 68
- Smeenk RJ., 2002, Clin Exp Rheumatol, 20, 294
- 10.1309/gjhk0d24yddxw0nf · doi:10.1309/gjhk0d24yddxw0nf · Paper page
- Abreu I, 2004, From animal models to human genetics: research on the induction and pathogenicity of autoantibodies, 467
Cited by
Mechanisms of Kidney Injury in Lupus Nephritis – the Role of Anti-dsDNA Antibodies
Yung, S., & Chan, T. M. (2015) · Frontiers in Immunology · doi:10.3389/fimmu.2015.00475 · Cited by 158
Mehra, S., & Fritzler, M. J. (2014) · Journal of Immunology Research · doi:10.1155/2014/368274 · Cited by 40
“ELISA techniques for ANuA detection differ in terms of the antigen preparations used.”
BackgroundInfluentialLaunay, D., Schmidt, J., Lepers, S., Mirault, T., Lambert, M., Kyndt, X., Reumaux, D., Duhamel, A., Hachulla, E., Hatron, P.-Y., et al. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.03.016 · Cited by 35
Laboratory evaluation of anti-dsDNA antibodies.
Cockx, M., Van Hoovels, L., De Langhe, E., Lenaerts, J., Thevissen, K., Persy, B., Bonroy, C., Vercammen, M., & Bossuyt, X. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.12.029 · Cited by 30
Buhl, A., Page, S., Heegaard, N. H. H., von Landenberg, P., & Luppa, P. B. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.06.037 · Cited by 29
Thaler, M., Buhl, A., Welter, H., Schreiegg, A., Kehrel, M., Alber, B., Metzger, J., & Luppa, P. B. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2340-1 · Cited by 31
Fiegel, F., Buhl, A., Jaekel, H.-P., Werle, E., Schmolke, M., Ollert, M., & Luppa, P. (2010) · Lupus · doi:10.1177/0961203310369681 · Cited by 24
Zhao, J., Wang, K., Wang, X., Li, T., Guo, L., Gu, L., Chen, Z., Sun, F., Wang, H., Li, J., et al. (2018) · Clinical Rheumatology · doi:10.1007/s10067-017-3771-x · Cited by 22
Žigon, P., Lakota, K., Čučnik, S., Švec, T., Ambrožič, A., Sodin-Šemrl, S., & Kveder, T. (2011) · Croatian Medical Journal · doi:10.3325/cmj.2011.52.694 · Cited by 19
Bauer, C.-J., Karakostas, P., Weber, N., Behning, C., Stoffel‐Wagner, B., Brossart, P., Dolscheid‐Pommerich, R., & Schäfer, V. S. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1305865 · Cited by 21
“…detect different anti-dsDNA subpopulations (18, 22) and may detect not only autoantibodies directed against dsDNA but also against other antigens (23, 24), and since autoantibodies detectable in SLE patients differ with respect to their associated SLE manifestations and clinical course (16, 25)…”
BackgroundToll-like receptor 9 in murine lupus: More friend than foe!
Yu, P., Musette, P., & Peng, S. L. (2007) · Immunobiology · doi:10.1016/j.imbio.2007.08.002 · Cited by 19
Infantino, M., Manfredi, M., Merone, M., Grossi, V., Benucci, M., Li Gobbi, F., Bandinelli, F., Damiani, A., & Soda, P. (2018) · Immunologic Research · doi:10.1007/s12026-018-8992-9 · Cited by 16
Yuan, W., Cao, H., Wan, P., Shi, R., Zhou, S., & Zheng, J. (2019) · Lupus · doi:10.1177/0961203319877243 · Cited by 15
Gerlach, S., Affeldt, K., Pototzki, L., Krause, C. D., Voigt, J., Fraune, J., & Fechner, K. (2015) · Journal of Immunology Research · doi:10.1155/2015/742402 · Cited by 19
“, Farr assays and PEG assays) and Crithidia luciliae indirect immunofluorescence tests (CLIFT) [13].”
MethodImproved diagnosis of systemic lupus erythematosus with human-derived double-stranded DNA antigen
Li, X., Tang, H., Chen, C., Niu, Q., Zhou, Z., Zheng, Y., Liu, Y., Munoz, L. E., i, M. H., Wu, P., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116809 · Cited by 13
Yang, J., Oh, E., Kim, Y., & Park, Y.-J. (2010) · Annals of Laboratory Medicine · doi:10.3343/kjlm.2010.30.6.675 · Cited by 14
Suh-Lailam, B. B., Chiaro, T. R., Wayne Davis, K., Wilson, A. R., & Tebo, A. E. (2011) · Europe PMC (PubMed Central) · Cited by 12
Atta, A. M., Pereira, M. M., Santiago, M., & Sousa-Atta, M. L. B. (2009) · Clinical Rheumatology · doi:10.1007/s10067-009-1134-y · Cited by 9
“Although the FARR immunoassay is the most efficient test to detect these immunoglobulins, and its results have been well correlated with global SLE activity, and renal and vasculitis involvement, it has been substituted in rheumatology laboratories by non-isotopic techniques, mainly indirect fluorescent antibody test…”
BackgroundMohammed, A. S., Boddu, P. C., Mael, D., Samee, M., & Villines, D. C. (2016) · Journal of Community Hospital Internal Medicine Perspectives · doi:10.3402/jchimp.v6.32031 · Cited by 6
“Enzyme immunoassays (EIA) testing removes the subjective variations of IIF testing (3); however, there exist interlaboratory method variations and heterophile antibody interferences causing false-positive results.”
Bardin, N., Ragot, C., & Sanmarco, M. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1398.057 · Cited by 7
Hormann, W., Hahn, M., Gerlach, S., Hochstrate, N., Affeldt, K., Giesen, J. E. H. M., Fechner, K., & Damoiseaux, J. G. M. C. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0326 · Cited by 3
“But further analysis of the 12 samples which showed discrepant results between routine CLIFT 1 and CLIFT 2 with the CLIFT 3 revealed that 11 samples reacted positive with the more sensitive test kit; highlighting the importance to know the specifications of an assay in use and to assess the preferred weighting of sens…”
BackgroundA fluorescence sedimentation assay for dsDNA antibodies
Duus, K., Draborg, A. H., Güven, E., Moreno, Y. M., Jacobsen, S., Nielsen, C. T., & Houen, G. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1339232 · Cited by 3
“The specificity and sensitivity of assays for dsDNA antibodies depend on the method used and a broad spectrum of assays has been elaborated in order to improve detection, characterization, and quantification of dsDNA antibodies [6,10].”
MethodThe role of the autoimmunity laboratory in autoimmune diseases
Hasson, S. S., Al-Balushi, M., & Al-Jabri, A. H. (2012) · Asian Pacific Journal of Tropical Disease · doi:10.1016/s2222-1808(12)60036-x · Cited by 2
“Some studies showed agreement between IIF and EIA[9,29] while others demonstrated differences in results[16,30].”
ResultNon-organ-specific autoantibodies in renal transplant recipients: relation to BK virus infection.
Costa, C. S., Touscoz, G. A., Bergallo, M., Sidoti, F., Terlizzi, M. E., Astegiano, S., Merlino, C., Segoloni, G., & Cavallo, R. (2008) · PubMed · Cited by 2
Comparison of quantitative and qualitative anti-dsDNA assays
Selvaratnam, R., Srivastava, P., Tacker, D. H., Thebo, J., & Wheeler, S. (2024) · Laboratory Medicine · doi:10.1093/labmed/lmae035 · Cited by 1
Predictors of Vasculitis in Patients With Systemic Lupus Erythematosus in Bangladesh
Sunny, S. S., Azad, M. A. K., Hassan, M. M., Asaduzzaman, A. T. M., & Islam, M. N. (2025) · Cureus · doi:10.7759/cureus.80868 · Cited by 1
Clinical evaluation of the novel digital liquid chip method for anti-dsDNA detection in SLE
Bai, Y., Yu, R., Xue, C., Wang, Q., Tian, X., Zeng, X., Li, M., & Hu, C. (2025) · Lupus Science & Medicine · doi:10.1136/lupus-2025-001608 · Cited by 1
Antigen Preparation for Immunological Studies in Systemic Autoimmune Diseases
Zampieri, S., Ghirardello, A., Rossini, K., Iaccarino, L., Bassi, N., Atzeni, F., Sarzi‐Puttini, P., & Doria, A. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1398.023 · Cited by 1
Reação imunoenzimática (ELISA) quantitativa para detecção de anticorpos IgG anti-DNA de dupla hélice
Cavalcante, E. O., Suzuki, L. A., & Rossi, C. L. (2019) · Jornal Brasileiro de Patologia e Medicina Laboratorial · doi:10.5935/1676-2444.20190018 · Cited by 1
Albani, J. R. (2016) · Wiley eBooks · doi:10.1002/9780470027318.a0101m.pub3 · Cited by 1
Studies on anti-dsDNA Antibodies and other potential biomarkers in Systemic Lupus Erythematosus
Compagno, M. (2015) · Lund University Publications (Lund University) · Cited by 2
Évaluation du kit Diasorin Liaison® dsDNA pour la détection des anticorps anti-DNA natif
Rouquette, A. M., Desgruelles, C., Lependeven, C., & Abuaf, N. (2007) · Immuno-analyse & Biologie Spécialisée · doi:10.1016/j.immbio.2006.12.002
Self-citationSynthetic Oligonucleotide Probes for Detection of Autoimmune Antibodies
Astakhova, K. (2014) · Journal of Clinical & Cellular Immunology · doi:10.4172/2155-9899.1000199
“Though the former is a more reliable test for autoimmune antibodies, the ELISA test is more preferred in clinics due to its low cost [18].”
BackgroundKobkitjaroen, J., Jaiyen, J., Kongkriengdach, S., Potprasart, S., & Viriyataveekul, R. (2013) · DOAJ (DOAJ: Directory of Open Access Journals)
Kim, N., Kim, I., Chang, C. L., Kim, H. H., & Lee, E. Y. (2018) · Kosin Medical Journal · doi:10.7180/kmj.2018.33.3.307
“All of them were diagnosed based on the diagnostic criteria suggested by the American College of Rheumatology.10,11 2.”
MethodReport on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test
Cheon, J. H., Kim, W. J., Kim, S. H., Moon, H. H., & Yoo, S. H. (2014)
Albani, J. R. (2011) · Wiley eBooks · doi:10.1002/9780470027318.a0101m.pub2
Metadata
- Authors
- Rouquette, A., & Desgruelles, C.
- Affiliations
- Hôpital Tenon (FR)
- Corresponding author
- Rouquette, AM
- Venue
- Lupus
- Publisher
- SAGE Publications
- Published
- 2006-07
- Volume
- 15
- Issue
- 7
- Pages
- 403-407
- ISSN
- 0961-2033 (ISSN-L)
- 1477-0962
- OpenAlex
- W1993599061
- Semantic Scholar
- 3b756156410b526b51ef12ed767abedaf43423a7
- Cited by
- 39
- References
- 42
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 1 · 2022: 1 · 2019: 2 · 2018: 2 · 2017: 4 · 2016: 2 · 2015: 3 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Lupus (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Rheumatology › Systemic Sclerosis and Related Diseases
- Health Sciences › Medicine › Rheumatology › Vasculitis and related conditions
- Keywords
- anti-dsDNA antibodies, systemic lupus erythematosus, laboratory assays, autoantibody detection, clinical significance, disease activity, microarray, autoimmune disease pathophysiology
- MeSH terms
- Antibodies, Antinuclear, Enzyme-Linked Immunosorbent Assay, Fluorescent Antibody Technique, Lupus Erythematosus, Systemic, Radioimmunoassay, Microarray Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.