CoChat

A sensitive and specific method for measurement of multiple retinoids in human serum with UHPLC-MS/MS

Open access

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Retinol (vitamin A) circulates at 1-4 μM concentration and is easily measured in serum. However, retinol is biologically inactive. Its metabolite, retinoic acid (RA), is believed to be responsible for biological effects of vitamin A, and hence the measurement of retinol concentrations is of limited value. A UHPLC-MS/MS method using isotope-labeled internal standards was developed and validated for quantitative analysis of endogenous RA isomers and metabolites. The method was used to measure retinoids in serum samples from 20 healthy men. In the fed state, the measured concentrations were 3.1 ± 0.2 nM for atRA, 0.1 ± 0.02 nM for 9-cisRA, 5.3 ± 1.3 nM for 13-cisRA, 0.4 ± 0.4 nM for 9,13-dicisRA, and 17.2 ± 6.8 nM for 4oxo-13-cisRA. The concentrations of the retinoids were not significantly different when measured after an overnight fast (3.0 ± 0.1 nM for atRA, 0.09 ± 0.01 nM for 9-cisRA, 3.9 ± 0.2 nM for 13-cisRA, 0.3 ± 0.1 nM for 9,13-dicisRA, and 11.9 ± 1.6 nM for 4oxo-13-cisRA). 11-cisRA and 4OH-RA were not detected in human serum. The high sensitivity of the MS/MS method combined with the UHPLC separation power allowed detection of endogenous 9-cisRA and 4oxo-atRA for the first time in human serum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1194/jlr.d019745

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Representative MS/MS spectra of RA, 4oxo-RA, and 4OH-RA standards and of RA and 4oxo-RA detected in serum samples. The MS/MS spectra of RA isomers and metabolites as clean standards and from serum samples were collected as described in Materials and Methods. The MS/MS spectra representative of all detected isomers are shown for at RA (A), 4oxo-13cis RA (C), and 4OHat RA (E) standards. Similar MS/MS spectra were generated for each quantifi ed retinoid in a sample of pooled human serum, and representative MS/MS spectra for at RA (B) and for 4oxo-13cis RA (D) are shown.
Fig. 1 Representative MS/MS spectra of RA, 4oxo-RA, and 4OH-RA standards and of RA and 4oxo-RA detected in serum samples. The MS/MS spectra of RA isomers and metabolites as clean standards and from serum samples were collected as described in Materials and Methods. The MS/MS spectra representative of all detected isomers are shown for at RA (A), 4oxo-13cis RA (C), and 4OHat RA (E) standards. Similar MS/MS spectra were generated for each quantifi ed retinoid in a sample of pooled human serum, and representative MS/MS spectra for at RA (B) and for 4oxo-13cis RA (D) are shown.CC-BY · From the PDF
Fig. 2 Separation of retinoic acid and 4oxo-RA isomers and detection of the retinoids and labeled internal standards in serum. Separation of at RA, 9,13dicis RA, 9cis RA, and 13cis RA standards (A) and detection of the same isomers in serum (C). (B) Separation of 4oxoat RA and 4oxo-13cis RA and (D) detection of these compounds in serum. The dotted line in panel (D) also shows the lack of detection of 4OH-RA in extracted serum. All serum samples were prepared by liquid-liquid extraction and analyzed as described in Materials and Methods. (E) Detection of 13cis RA-d 5 internal standard (at 13.2 min) extracted from serum together with the structure of the labeled compound. The peak at 13.9 min is not a retinoid but a matrix peak. (F) Detection of 4oxo-13cis RA-d 3 internal standard in serum together with the structure of the internal standard. Panels E and F also show the lack of isomerization of the internal standards in serum. The insets on each panel specify the MS/MS transition used for the specifi c analyte.
Fig. 2 Separation of retinoic acid and 4oxo-RA isomers and detection of the retinoids and labeled internal standards in serum. Separation of at RA, 9,13dicis RA, 9cis RA, and 13cis RA standards (A) and detection of the same isomers in serum (C). (B) Separation of 4oxoat RA and 4oxo-13cis RA and (D) detection of these compounds in serum. The dotted line in panel (D) also shows the lack of detection of 4OH-RA in extracted serum. All serum samples were prepared by liquid-liquid extraction and analyzed as described in Materials and Methods. (E) Detection of 13cis RA-d 5 internal standard (at 13.2 min) extracted from serum together with the structure of the labeled compound. The peak at 13.9 min is not a retinoid but a matrix peak. (F) Detection of 4oxo-13cis RA-d 3 internal standard in serum together with the structure of the internal standard. Panels E and F also show the lack of isomerization of the internal standards in serum. The insets on each panel specify the MS/MS transition used for the specifi c analyte.CC-BY · From the PDF
Fig. 3 Chromatograms of the detected retinoids as standards at determined LLOD. The on-column LLOD and LLOQ values for each compound are shown in the inset table. All retinoids were measured using the MS/MS transitions summarized in Table 1, and the corresponding SRM channels ( m/z 301 > 205 for RA isomers, m/z 315 > 159 for 4oxo-RA isomers, and m/z 299 > 157 for 4OH-RA isomers) are shown.
Fig. 3 Chromatograms of the detected retinoids as standards at determined LLOD. The on-column LLOD and LLOQ values for each compound are shown in the inset table. All retinoids were measured using the MS/MS transitions summarized in Table 1, and the corresponding SRM channels ( m/z 301 > 205 for RA isomers, m/z 315 > 159 for 4oxo-RA isomers, and m/z 299 > 157 for 4OH-RA isomers) are shown.CC-BY · From the PDF
Fig. 4 Evaluation of the presence of 11-cisRA in serum. (A) Light-protected serum sample without the addition of 11cis RA and palladium(II)nitrate extracted as described in Materials and Methods. (C) Chromatogram of an aliquot of the same extracted sample spiked with 11-cisRA. Fractions of both samples were treated with palladium(II)nitrate. (B and D) Chromatograms of the serum samples after the reaction. No decrease in 9,13dicis RA peak between panel A and B is detected, and no increase in at RA peak suggesting that 11cis RA was not present in serum. In the control reaction, the spiked 11cis RA was quantitatively converted to at RA (panel C vs. D).
Fig. 4 Evaluation of the presence of 11-cisRA in serum. (A) Light-protected serum sample without the addition of 11cis RA and palladium(II)nitrate extracted as described in Materials and Methods. (C) Chromatogram of an aliquot of the same extracted sample spiked with 11-cisRA. Fractions of both samples were treated with palladium(II)nitrate. (B and D) Chromatograms of the serum samples after the reaction. No decrease in 9,13dicis RA peak between panel A and B is detected, and no increase in at RA peak suggesting that 11cis RA was not present in serum. In the control reaction, the spiked 11cis RA was quantitatively converted to at RA (panel C vs. D).CC-BY · From the PDF
Fig. 5 Detection of 4OH-RA isomers in human serum using an ACN protein precipitation and centrifugation for sample preparation. Blank serum (A), 5 nM 4OHat RA and 4OH-9cis RA spiked into blank serum (B), and a representative human serum sample (C) are shown. The peak at 5.75 min in panel C is likely 4OHat RA, but the peak area is below LLOQ for this compound.
Fig. 5 Detection of 4OH-RA isomers in human serum using an ACN protein precipitation and centrifugation for sample preparation. Blank serum (A), 5 nM 4OHat RA and 4OH-9cis RA spiked into blank serum (B), and a representative human serum sample (C) are shown. The peak at 5.75 min in panel C is likely 4OHat RA, but the peak area is below LLOQ for this compound.CC-BY · From the PDF
Fig. 6 Box and whiskers plots for endogenous retinoid concentrations in serum. The box represents the 25th and 75th percentiles of each group. The whiskers are determined based on 10th and 90th percentiles, and outliers are calculated as 1.5 times the mean of the sample set. All of the retinoid concentrations, with the exception of 4oxo-13cis RA, are plotted against the left y axis. The 4oxo-13cis RA concentrations are plotted against the right hand y axis.
Fig. 6 Box and whiskers plots for endogenous retinoid concentrations in serum. The box represents the 25th and 75th percentiles of each group. The whiskers are determined based on 10th and 90th percentiles, and outliers are calculated as 1.5 times the mean of the sample set. All of the retinoid concentrations, with the exception of 4oxo-13cis RA, are plotted against the left y axis. The 4oxo-13cis RA concentrations are plotted against the right hand y axis.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

Items 101–119 of 119

Metadata

Authors
Arnold, S. L. M., Amory, J. K., Walsh, T. J., & Isoherranen, N.
Affiliations
University of Washington (US)
Corresponding author
Isoherranen, Nina
Venue
Journal of Lipid Research
Publisher
Elsevier BV
Published
2012-03
Volume
53
Issue
3
Pages
587-598
ISSN
0022-2275 (ISSN-L)
OpenAlex
W2119742360
Cited by
119
References
35
Citations by year
2026: 3 · 2025: 4 · 2024: 12 · 2023: 11 · 2022: 9 · 2021: 7 · 2020: 10 · 2019: 9 · 2018: 14 · 2017: 10 · 2016: 2 · 2015: 10 · 2014: 6 · 2013: 7 · 2012: 4
FWCI
2.21
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Lipid Research (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Institutes of Health (GM081569)
  • National Institute of General Medical Sciences (GM081569-S1, R01GM081569)
  • National Institute of Child Health and Human Development
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (U01HD060408)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinoids in leukemia and cellular processes
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
retinoids, retinoic acid, 9-cis-retinoic acid, isotretinoin, retinol, vitamin A, isotope-labeled internal standards, UPLC-MS/MS, fed versus fasted state
MeSH terms
Adolescent, Adult, Aged, Chromatography, High Pressure Liquid, Humans, Male, Middle Aged, Retinoids, Tretinoin, Reproducibility of Results, Tandem Mass Spectrometry, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.