CoChat

A Risk Analysis Method to Evaluate the Impact of a Computerized Provider Order Entry System on Patient Safety

Open access
Bonnabry, P., Despont-Gros, C., Grauser, D., Casez, P., Despond, M., Pugin, D., Rivara-Mangeat, C., Koch, M., Vial, M., Iten, A., Lovis, C. · 2008 · Journal of the American Medical Informatics Association
Cited by 111

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Quantitative evaluation of safety after the implementation of a computerized provider order entry (CPOE) system, stratification of residual risks to drive future developments. DESIGN: Comparative risk analysis of the drug prescription process before and after the implementation of CPOE system, according to the Failure Modes, Effects and Criticality Analysis (FMECA) method. MEASUREMENTS: The failure modes were defined and their criticality indices calculated on the basis of the likelihood of occurrence, potential severity for patients, and detection probability. Criticality indices of handwritten and electronic prescriptions were compared, the acceptability of residual risks was discussed. Further developments were proposed and their potential impact on the safety was estimated. RESULTS: The sum of criticality indices of 27 identified failure modes was 3813 for the handwritten prescription, 2930 (-23%) for CPOE system, and 1658 (-57%) with 14 enhancements. The major safety improvements were observed for errors due to ambiguous, incomplete or illegible orders (-245 points), wrong dose determination (-217) and interactions (-196). Implementation of targeted pop-ups to remind treatment adaptation (-189), vital signs (-140), and automatic edition of documents needed for the dispensation (-126) were the most promising proposed improvements. CONCLUSION: The impact of a CPOE system on patient safety strongly depends on the implemented functions and their ergonomics. The use of risk analysis helps to quantitatively evaluate the relationship between a system and patient safety and to build a strategy for continuous quality improvement, by selecting the most appropriate improvements to the system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1197/jamia.m2677

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 111

Metadata

Authors
Bonnabry, P., Despont-Gros, C., Grauser, D., Casez, P., Despond, M., Pugin, D., Rivara-Mangeat, C., Koch, M., Vial, M., Iten, A., & Lovis, C.
Venue
Journal of the American Medical Informatics Association
Published
2008-07-01
Volume
15
Issue
4
Pages
453-460
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2159502598
Cited by
111
References
11
FWCI
15.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.