Validation of Knowledge Acquisition for Surgical Process Models
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Surgical Process Models (SPMs) are models of surgical interventions. The objectives of this study are to validate acquisition methods for Surgical Process Models and to assess the performance of different observer populations. DESIGN: The study examined 180 SPM of simulated Functional Endoscopic Sinus Surgeries (FESS), recorded with observation software. About 150,000 single measurements in total were analyzed. MEASUREMENTS: Validation metrics were used for assessing the granularity, content accuracy, and temporal accuracy of structures of SPMs. RESULTS: Differences between live observations and video observations are not statistically significant. Observations performed by subjects with medical backgrounds gave better results than observations performed by subjects with technical backgrounds. Granularity was reconstructed correctly by 90%, content by 91%, and the mean temporal accuracy was 1.8 s. CONCLUSION: The study shows the validity of video as well as live observations for modeling Surgical Process Models. For routine use, the authors recommend live observations due to their flexibility and effectiveness. If high precision is needed or the SPM parameters are altered during the study, video observations are the preferable approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research
(1988) · Advances in Psychology · doi:10.1016/s0166-4115(08)62386-9 · Cited by 15,003
Assessing Data Quality in Manual Entry of Ventilator Settings
Vawdrey, D. K., Gardner, R. M., Evans, R. S., Orme, J. F., Clemmer, T. P., Greenway, L., & Drews, F. A. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2219 · Cited by 48 · cited 2×
“Validation of data acquisition in the clinical domain has been performed by Vawdrey et al.10 who assessed the data quality of ventilators operated by respiratory therapists.”
Method
Cited by
Statistical modeling and recognition of surgical workflow
Padoy, N., Blum, T., Ahmadi, S.-A., Feussner, H., Berger, M.-O., & Navab, N. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.10.001 · Cited by 279
Surgical process modelling: a review
Lalys, F., & Jannin, P. (2014) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0940-5 · Cited by 258
Self-citationComputational Health Informatics in the Big Data Age: A Survey
Fang, R., Pouyanfar, S., Yang, Y., Chen, S.-C., & Iyengar, S. S. (2017) · ACM Computing Surveys · doi:10.1145/2932707 · Cited by 210
Uncertainty-aware organ classification for surgical data science applications in laparoscopy
Moccia, S., Wirkert, S. J., Kenngott, H., Vemuri, A. S., Apitz, M., Mayer, B., De Momi, E., Mattos, L. S., & Maier-Hein, L. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2813015 · Cited by 56
Metadata
- Authors
- Neumuth, T., Jannin, P., Strauss, G., Meixensberger, J., & Burgert, O.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01-01
- Volume
- 16
- Issue
- 1
- Pages
- 72-80
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W1527124053
- Cited by
- 112
- References
- 2
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.