Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Purpose: We use changes in tumor measurements to assess response and progression, both in routine care and as the primary objective of clinical trials. However, the variability of computed tomography (CT) –based tumor measurement has not been comprehensively evaluated. In this study, we assess the variability of lung tumor measurement using repeat CT scans performed within 15 minutes of each other and discuss the implications of this variability in a clinical context. Patients and Methods: Patients with non–small-cell lung cancer and a target lung lesion ≥ 1 cm consented to undergo two CT scans within a period of minutes. Three experienced radiologists measured the diameter of the target lesion on the two scans in a side-by-side fashion, and differences were compared. Results: Fifty-seven percent of changes exceeded 1 mm in magnitude, and 33% of changes exceeded 2 mm. Median increase and decrease in tumor measurements were +4.3% and −4.2%, respectively, and ranged from 23% shrinkage to 31% growth. Measurement changes were within ± 10% for 84% of measurements, whereas 3% met criteria for progression according to Response Evaluation Criteria in Solid Tumors (RECIST; ≥ 20% increase). Smaller lesions had greater variability of percent measurement change (P = .005). Conclusion: Apparent changes in tumor diameter exceeding 1 to 2 mm are common on immediate reimaging. Increases and decreases less than 10% can be a result of the inherent variability of reimaging. Caution should be exercised in interpreting the significance of small changes in lesion size in the care of individual patients and in the interpretation of clinical trial results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534 · cited 1×
“The former is the measure of change directly observable, whereas the latter is the metric used commonly in clinical trials.(13) This random assignment step was repeated 1,000 times, resulting in 1,000 distributions of the change (in millimeters) and of the relative change.”
MethodSelf-citationReporting results of cancer treatment
Miller, A. B., Hoogstraten, B., Staquet, M., & Winkler, A. (1981) · Cancer · doi:10.1002/1097-0142(19810101)47:1<207::aid-cncr2820470134>3.0.co;2-6 · Cited by 7,793
Erasmus, J. J., Gladish, G. W., Broemeling, L., Sabloff, B. S., Truong, M. T., Herbst, R. S., & Munden, R. F. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.01.144 · Cited by 476 · cited 1×
“Several studies have tried to quantify this variability by having radiologists perform repeat measurements on a single set of CT scans.(3-6) Separately, the process of performing a CT scan can lead to changes in the appearance of a tumor or JOURNAL OF CLINICAL ONCOLOGY O R I G I N A L R E P O R T”
BackgroundZhao, B., James, L. P., Moskowitz, C. S., Guo, P., Ginsberg, M. S., Lefkowitz, R. A., Qin, Y., Riely, G. J., Kris, M. G., & Schwartz, L. H. (2009) · Radiology · doi:10.1148/radiol.2522081593 · Cited by 339
Self-citationVolumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289
Karrison, T. G., Maitland, M. L., Stadler, W. M., & Ratain, M. J. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm158 · Cited by 177 · cited 2×
“This work also may have important implications for the interpretation of tumor response, particularly when measurement change is considered as a continuous variable, a technique increasingly considered as a way of better expressing a therapy’s antitumor activity.(1-2,14) One analysis often used is the waterfall plot,…”
BackgroundMethodThiesse, P., Ollivier, L., Di Stefano-Louineau, D., Négrier, S., Savary, J., Pignard, K., Lasset, C., & Escudier, B. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.12.3507 · Cited by 168 · cited 1×
“Several studies have tried to quantify this variability by having radiologists perform repeat measurements on a single set of CT scans.(3-6) Separately, the process of performing a CT scan can lead to changes in the appearance of a tumor or JOURNAL OF CLINICAL ONCOLOGY O R I G I N A L R E P O R T”
BackgroundGoodman, L. R., Gülsün, M., Washington, L., Nagy, P. G., & Piacsek, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1821 · Cited by 144 · cited 1×
“Prior rescan studies have had limited applicability to clinical oncology because these have looked at small lung nodules of unclear malignant potential.(9-11) Additionally, we previously published a rescan analysis of the clinical study reported here that compared manual measurement to semi-automated measurement; howe…”
Cesne, A. L., Glabbeke, M. M. V., Verweij, J., Casali, P. G., Findlay, M. P. N., Reichardt, P., Issels, R. D., Judson, I. R., Schöffski, P., Leyvraz, S., et al. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.21.3330 · Cited by 120 · cited 1×
“Interestingly, several groups have found that a 10% decrease in tumor diameter may be correlated with better outcomes in some cancers.(18-21) Because this study measured only a single lesion for each patient, we are not able to quantify how summed measurement of multiple lesions might affect variability, although we c…”
BackgroundZhao, B., Oxnard, G. R., Moskowitz, C. S., Kris, M. G., Pao, W., Guo, P., Rusch, V. M., Ladanyi, M., Rizvi, N. A., & Schwartz, L. H. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-0125 · Cited by 112 · cited 1×
“Interestingly, several groups have found that a 10% decrease in tumor diameter may be correlated with better outcomes in some cancers.(18-21) Because this study measured only a single lesion for each patient, we are not able to quantify how summed measurement of multiple lesions might affect variability, although we c…”
BackgroundSelf-citationEvaluation of Tumor Measurements in Oncology: Use of Film-Based and Electronic Techniques
Schwartz, L. H., Ginsberg, M. S., DeCorato, D. R., Rothenberg, L. N., Einstein, S. G., Kijewski, P. K., & Panicek, D. M. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.10.2179 · Cited by 102 · cited 1×
“Lastly, it has been found that the technique used for processing CT imaging data can contribute to measurement variability.(7-9) However, prior studies assessing measurement variability have studied only one step of the imaging process; although these studies may be useful for investigations into reducing measurement…”
MethodSelf-citationPhase II Trial of Gefitinib and Everolimus in Advanced Non-small Cell Lung Cancer
Price, K. A. R., Azzoli, C. G., Krug, L. M., Pietanza, M. C., Rizvi, N. A., Pao, W. J., Kris, M. G., Riely, G. J., Heelan, R. T., Arcila, M. E., et al. (2010) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e3181ec1531 · Cited by 97 · cited 2×
“Relative change of longest dimension of indicator lesions, using data from a recently completed phase II study of targeted therapy in non–small-cell lung cancer.(15) The gray zone demarcates changes of less than 10%, highlighting the fact that changes in this range may be a result of variability alone.”
MethodSelf-citationPiessevaux, H. H., Buyse, M. E., Roock, W. D., Prenen, H., Schlichting, M., Cutsem, E. V., & Tejpar, S. (2009) · Annals of Oncology · doi:10.1093/annonc/mdp011 · Cited by 91 · cited 1×
“Interestingly, several groups have found that a 10% decrease in tumor diameter may be correlated with better outcomes in some cancers.(18-21) Because this study measured only a single lesion for each patient, we are not able to quantify how summed measurement of multiple lesions might affect variability, although we c…”
BackgroundArmato, S. G., Oxnard, G. R., MacMahon, H., Vogelzang, N. J., Kindler, H. L., Kocherginsky, M., & Starkey, A. (2004) · Medical Physics · doi:10.1118/1.1688211 · Cited by 79
Self-citationPulmonary Metastases: Effect of CT Section Thickness on Measurement—Initial Experience
Zhao, B., Schwartz, L. H., Moskowitz, C. S., Wang, L., Ginsberg, M. S., Cooper, C., Jiang, L., & Kalaigian, J. (2005) · Radiology · doi:10.1148/radiol.2343040020 · Cited by 49
Self-citationLoRusso, P. M., Anderson, A. B., Boerner, S. A., & Averbuch, S. D. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-1279 · Cited by 40 · cited 2×
“This work also may have important implications for the interpretation of tumor response, particularly when measurement change is considered as a continuous variable, a technique increasingly considered as a way of better expressing a therapy’s antitumor activity.(1-2,14) One analysis often used is the waterfall plot,…”
BackgroundMethodVolumes to Learn: Advancing Therapeutics with Innovative Computed Tomography Image Data Analysis
Maitland, M. L. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-1548 · Cited by 11
Cited by
Monitoring immune-checkpoint blockade: response evaluation and biomarker development
Nishino, M., Ramaiya, N. H., Hatabu, H., & Hodi, F. S. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.88 · Cited by 1,023
Deep learning for lung cancer prognostication: A retrospective multi-cohort radiomics study
Hosny, A., Parmar, C., Coroller, T. P., Grossmann, P., Zeleznik, R., Kumar, A., Bussink, J., Gillies, R. J., Mak, R. H., & Aerts, H. J. W. L. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002711 · Cited by 579
“Feature stability was quantified using the intraclass correlation coefficient (ICC), using the irr package [42] and the test–retest RIDER dataset [33,43].”
MethodChristensen, E., Birkenkamp-Demtröder, K., Sethi, H., Shchegrova, S., Salari, R., Nordentoft, I., Wu, H.-T., Knudsen, M., Lamy, P., Lindskrog, S. V., et al. (2019) · Journal of Clinical Oncology · doi:10.1200/jco.18.02052 · Cited by 556
Cheson, B. D., Ansell, S., Schwartz, L., Gordon, L. I., Advani, R., Jacene, H. A., Hoos, A., Barrington, S. F., & Armand, P. (2016) · Blood · doi:10.1182/blood-2016-05-718528 · Cited by 521
Self-citationReproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Self-citation
Metadata
- Authors
- Oxnard, G. R., Zhao, B., Sima, C. S., Ginsberg, M. S., James, L. P., Lefkowitz, R. A., Guo, P., Kris, M. G., Schwartz, L. H., & Riely, G. J.
- Venue
- Journal of Clinical Oncology
- Published
- 2011-08-10
- Volume
- 29
- Issue
- 23
- Pages
- 3114-3119
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2122538591
- Cited by
- 161
- References
- 17
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.