The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abbreviated Breast Magnetic Resonance Imaging (MRI): First Postcontrast Subtracted Images and Maximum-Intensity Projection—A Novel Approach to Breast Cancer Screening With MRI
Abstract
Purpose: We investigated whether an abbreviated protocol (AP), consisting of only one pre- and one postcontrast acquisition and their derived images (first postcontrast subtracted [FAST] and maximum-intensity projection [MIP] images), was suitable for breast magnetic resonance imaging (MRI) screening. Methods: We conducted a prospective observational reader study in 443 women at mildly to moderately increased risk who underwent 606 screening MRIs. Eligible women had normal or benign digital mammograms and, for those with heterogeneously dense or extremely dense breasts (n = 427), normal or benign ultrasounds. Expert radiologists reviewed the MIP image first to search for significant enhancement and then reviewed the complete AP (consisting of MIP and FAST images and optionally their nonsubtracted source images) to characterize enhancement and establish a diagnosis. Only thereafter was the regular full diagnostic protocol (FDP) analyzed. Results: MRI acquisition time for FDP was 17 minutes, versus 3 minutes for the AP. Average time to read the single MIP and complete AP was 2.8 and 28 seconds, respectively. Eleven breast cancers (four ductal carcinomas in situ and seven invasive cancers; all T1N0 intermediate or high grade) were diagnosed, for an additional cancer yield of 18.2 per 1,000. MIP readings were positive in 10 (90.9%) of 11 cancers and allowed establishment of the absence of breast cancer, with a negative predictive value (NPV) of 99.8% (418 of 419). Interpretation of the complete AP, as with the FDP, allowed diagnosis of all cancers (11 [100%] of 11). Specificity and positive predictive value (PPV) of AP versus FDP were equivalent (94.3% v 93.9% and 24.4% v 23.4%, respectively). Conclusion: An MRI acquisition time of 3 minutes and an expert radiologist MIP image reading time of 3 seconds are sufficient to establish the absence of breast cancer, with an NPV of 99.8%. With a reading time < 30 seconds for the complete AP, diagnostic accuracy was equivalent to that of the FDP and resulted in an additional cancer yield of 18.2 per 1,000.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Practice of Screening for Disease.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-5-1085_2 · Cited by 3,066
American Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Kriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Kuhl, C. K., Schrading, S., Leutner, C. C., Morakkabati-Spitz, N., Wardelmann, E., Fimmers, R., Kuhn, W., & Schild, H. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2004.00.4960 · Cited by 1,147
Self-citationPerry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., & von Karsa, L. (2008) · Annals of Oncology · doi:10.1093/annonc/mdm481 · Cited by 1,020
MRI Evaluation of the Contralateral Breast in Women with Recently Diagnosed Breast Cancer
Lehman, C. D., Gatsonis, C., Kuhl, C. K., Hendrick, R. E., Pisano, E. D., Hanna, L., Peacock, S., Smazal, S. F., Maki, D. D., Julian, T. B., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065447 · Cited by 945
Self-citationMR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759
MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study
Kuhl, C. K., Schrading, S., Bieling, H. B., Wardelmann, E., Leutner, C. C., Koenig, R., Kuhn, W., & Schild, H. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61232-x · Cited by 711
Self-citationHarms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993) · Radiology · doi:10.1148/radiology.187.2.8475297 · Cited by 634
Magnetic Resonance Imaging of the Breast Prior to Biopsy
Bluemke, D. A. (2004) · JAMA · doi:10.1001/jama.292.22.2735 · Cited by 513
Kuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501
Self-citationMRI for breast cancer screening, diagnosis, and treatment
Morrow, M., Waters, J., & Morris, E. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61350-0 · Cited by 448
Screening women at high risk for breast cancer with mammography and magnetic resonance imaging
Lehman, C. D., Blume, J. D., Weatherall, P., Thickman, D., Hylton, N., Warner, E., Pisano, E., Schnitt, S. J., Gatsonis, C., Schnall, M., et al. (2005) · Cancer · doi:10.1002/cncr.20971 · Cited by 401
Sardanelli, F., Podo, F., Santoro, F., Manoukian, S., Bergonzi, S., Trecate, G., Vergnaghi, D., Federico, M., Cortesi, L., Corcione, S., et al. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f3fcdf · Cited by 337
Warner, E., Hill, K., Causer, P., Plewes, D., Jong, R., Yaffe, M., Foulkes, W. D., Ghadirian, P., Lynch, H., Couch, F., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2009.27.0835 · Cited by 280
Long-term results of screening with magnetic resonance imaging in women with BRCA mutations
Passaperuma, K., Warner, E., Causer, P. A., Hill, K. A., Messner, S., Wong, J. W., Jong, R. A., Wright, F. C., Yaffe, M. J., Ramsay, E. A., et al. (2012) · British Journal of Cancer · doi:10.1038/bjc.2012.204 · Cited by 183
Patterns of Breast Magnetic Resonance Imaging Use in Community Practice
Wernli, K. J., DeMartini, W. B., Ichikawa, L., Lehman, C. D., Onega, T., Kerlikowske, K. M., Henderson, L. M., Geller, B. M., Hofmann, M., & Yankaskas, B. C. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.11963 · Cited by 148
Lowry, K. P., Lee, J. M., Kong, C. Y., McMahon, P. M., Gilmore, M. E., Chubiz, J. E. C., Pisano, E. D., Gatsonis, C. A., Ryan, P. D., Ozanne, E. M., et al. (2011) · Cancer · doi:10.1002/cncr.26424 · Cited by 134
Screening Breast MR Imaging in Women with a History of Lobular Carcinoma in Situ
Sung, J. S., Malak, S. F., Bajaj, P., Alis, R., Dershaw, D. D., & Morris, E. A. (2011) · Radiology · doi:10.1148/radiol.11110091 · Cited by 96
Chubiz, J. E. C., Lee, J. M., Gilmore, M. E., Kong, C. Y., Lowry, K. P., Halpern, E. F., McMahon, P. M., Paula D, R., & Gazelle, G. S. (2012) · Cancer · doi:10.1002/cncr.27864 · Cited by 88
Kim, J. Y., Cho, N., Koo, H. R., Yi, A., Kim, W. H., Lee, S. H., Chang, J. M., Han, W., Moon, H., Im, S., et al. (2013) · Radiology · doi:10.1148/radiol.12120629 · Cited by 63
Pediconi, F., Miglio, E., Telesca, M., Luciani, M. L., Kirchin, M. A., Passariello, R., & Catalano, C. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e318230061c · Cited by 60
Interpretation Time of Computer-aided Detection at Screening Mammography
Tchou, P. M., Haygood, T. M., Atkinson, E. N., Stephens, T. W., Davis, P., Arribas, E. M., Geiser, W. R., & Whitman, G. J. (2010) · Radiology · doi:10.1148/radiol.10092170 · Cited by 49
Managing magnetic resonance imaging machines: support tools for scheduling and planning
Carpenter, A., Leemis, L. M., Papir, A. S., Phillips, D. J., & Phillips, G. S. (2011) · Health Care Management Science · doi:10.1007/s10729-011-9153-z · Cited by 34
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
Smith, R. A., Andrews, K. S., Brooks, D., Fedewa, S. A., Manassaram‐Baptiste, D., Saslow, D., Brawley, O. W., & Wender, R. C. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21446 · Cited by 571
Smith, R. A., Manassaram-Baptiste, D., Brooks, D., Cokkinides, V., Doroshenk, M., Saslow, D., Wender, R. C., & Brawley, O. W. (2014) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21212 · Cited by 478
Comstock, C. E., Gatsonis, C., Newstead, G. M., Snyder, B. S., Gareen, I. F., Bergin, J. T., Rahbar, H., Sung, J. S., Jacobs, C., Harvey, J. A., et al. (2020) · JAMA · doi:10.1001/jama.2020.0572 · Cited by 456
Self-citationMelnikow, J., Fenton, J. J., Whitlock, E. P., Miglioretti, D. L., Weyrich, M. S., Thompson, J. H., & Shah, K. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1789 · Cited by 376
Metadata
- Authors
- Kuhl, C. K., Schrading, S., Strobel, K., Schild, H. H., Hilgers, R.-D., & Bieling, H. B.
- Venue
- Journal of Clinical Oncology
- Published
- 2014-08-01
- Volume
- 32
- Issue
- 22
- Pages
- 2304-2310
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2141798739
- Cited by
- 679
- References
- 28
- FWCI
- 32.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.