The DOI matches its Crossref record.
Fiber Optic Sensors
Abstract
Fiber optic sensors have become indispensable tools for biomedical study because of their unique features such as (1) high sensitivity, (2) small footprint and endoscopic compatibility, (3) multiple agent distributive sensing capability, and (4) immunity from electromagnetic interference. In this chapter, we will provide a brief overview on the basic principle of fiber optic sensors, types of fiber optic sensors, and their applications to biomedical sensing. As a result of the page limitation, important work in this area may not be included in this chapter. Readers may find those contents in the listed reference material. Keywords: fiber optic sensors; light; sensing mechanism; biomedical sensing
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736
The role of advanced sensing in smart cities
Hancke, G., Silva, B., & Hancke, Jr. (2012) · Sensors · doi:10.3390/s130100393 · Cited by 626
Fiber-Optic Sensing: A Historical Perspective
Culshaw, B., & Kersey, A. (2008) · Journal of Lightwave Technology · doi:10.1109/jlt.0082.921915 · Cited by 457
Optical Fiber Sensor Technologies: Opportunities and—Perhaps—Pitfalls
Culshaw, B. (2004) · Journal of Lightwave Technology · doi:10.1109/jlt.2003.822139 · Cited by 427
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Metadata
- Venue
- CRC Press eBooks
- Publisher
- CRC Press
- Published
- 2002-03-15
- OpenAlex
- W1503924230
- Cited by
- 510
- References
- 0
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.