CoChat

In Vivo Two-Photon Laser Scanning Microscopy with Concurrent Plasma-Mediated Ablation Principles and Hardware Realization

Tsai, Philbert, Kleinfeld, David · 2009 · Frontiers in Neuroscience
Cited by 35

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Many biological processes of current interest occur below the surface layers of accessible tissue. It is often the case that the surface layers cannot easily be removed without adversely affecting the physiology and function of the deeper layers. A variety of imaging techniques have been developed to perform sectioning deep to the surface using optical, electrical, and magnetic contrast agents and recording methods. Two-photon laser scanning microscopy (TPLSM) with ultrashort (i.e., order 100-fs) pulsed laser light provides optically sectioned images from depths of 500 microns or more below the surface in highly scattering brain tissue [1–5]. This method is unique in that it can provide images with submicrometer lateral resolution and micrometer axial resolution on the millisecond time-scale [6], as is required for the study of many dynamic biological processes [1,7–11].A strength of TPLSM is the ease with which this technique may be combined with electrical measurements of physiological parameters and with other optical techniques. These include one-photon uncaging with gated continuous laser light, two-photon uncaging with ultrashort pulsed laser light and, of particular interest in this work, plasma-mediated ablation through the nonlinear absorption of amplified ultrashort laser pulses.A nonlinear interaction that is of particular relevance for the ablation of submicrometer volumes of neuronal [12] and vascular [13] tissue deep in the brain is plasma-mediated ablation [14–16]. Here, the optical field of the ultrashort pulse leads to a high rate of tunneling by electrons to form an electron plasma [17]. The density of this plasma rapidly builds up by virtue of field-driven collisions between free electrons and molecules, while the thickness of the plasma approaches a value that is much less than the depth of the focal volume. The absorption of laser light by this thin layer leads to highly localized ablation and the explosive removal of material. One critical feature of plasma-mediated ablation is that light outside of the focal volume has little detrimental effect on the specimens; this limits the thermal build-up and ensuing collateral damage in the targeted tissue.This chapter provides an overview of the technical considerations relevant to the design and assembly of a system for TPLSM that is particularly suitable for in vivo imaging and histology, either alone or in combination with plasma-mediated ablation. It extends an earlier technical presentation [18] and complements other designs of upright systems [19–21]. The conversion of commercially available confocal microscopes for use in TPLSM, rather than the de novo construction of a system, have been described [22–26]. Commercial systems for TPLSM are available from Prairie (Ultima; www.prairie-technologies.com ) and Leica (TPS MP; www.leica.com ), and it is likely that the commercial market will continue to mature. Commercial systems that incorporate amplified ultrashort laser pulses do not exist at this time, although it should be simple to adapt current systems to support two beams.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1201/9781420076851.ch3

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Tsai, P., & Kleinfeld, D.
Venue
Frontiers in Neuroscience
Publisher
CRC Press
Published
2009-05-06
Pages
59-115
ISSN
2154-5723 (ISSN-L)
OpenAlex
W2261077834
Cited by
35
References
6
FWCI
14.45
Type
book chapter
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.