The DOI matches its Crossref record.
Atomic Absorption Spectrometry
Abstract
The basis of atomic absorption spectrometry (AAS) is the absorption of discrete wavelengths of light by ground-state, gas-phase free atoms. Free atoms in the gas phase are formed from the sample by an “atomizer” at high temperature. AAS was developed in the 1950s by Alan Walsh and rapidly became a widely used analytical tool. AAS is an elemental analysis technique capable of providing quantitative information on ∼70 elements in almost any type of sample. As an elemental analysis technique, it has the signicant advantage in many (but not all) cases of being practically independent of the chemical form of the element in the sample. A determination of cadmium in a water sample is a determination of the total cadmium concentration. It does not matter whether the cadmium exists as the chloride, sulfate, or nitrate, or even if it exists as a complex or an organometallic compound, if the proper analysis conditions are used. Concentrations as low as ppt levels of some elements in solution can be determined and AAS is used routinely to determine ppb and ppm concentrations of most metal elements. Another principal advantage is that a given element can be determined in the presence of other elements, which do not interfere by absorption of the analyte wavelength. Therefore, it is not necessary to separate the analyte from the rest of the sample (the matrix). This results in rapid analysis times and eliminates some sources of error. This is not to say that AAS measurements are completely free from interferences; both chemical and spectral interferences do occur and must be compensated for, as will be discussed. The major disadvantages of AAS are that no information is obtained on the chemical form of the analyte (no “speciation”) and that often only one element can be determined at a time. The latter makes AAS of very limited use for qualitative analysis. AAS is used almost exclusively for quantitative analysis of elements, hence the use of the term “spectrometry” in the name of the technique instead of “spectroscopy.”
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human Health Risk Assessment for Aluminium, Aluminium Oxide, and Aluminium Hydroxide
Krewski, D., Yokel, R. A., Nieboer, E., Borchelt, D., Cohen, J., Harry, J., Kacew, S., Lindsay, J., Mahfouz, A. M., & Rondeau, V. (2007) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937400701597766 · Cited by 998
Zeini Jahromi, E., Bidari, A., Assadi, Y., Milani Hosseini, M. R., & Jamali, M. R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.007 · Cited by 398
Ammonium biosorption onto sawdust: FTIR analysis, kinetics and adsorption isotherms modeling
Wahab, M. A., Jellali, S., & Jedidi, N. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.01.121 · Cited by 332
Ecotypic variation in selenium accumulation among populations of Stanleya pinnata
Feist, L. J., & Parker, D. R. (2001) · New Phytologist · doi:10.1046/j.1469-8137.2001.00004.x · Cited by 125
Dadfarnia, S., Salmanzadeh, A. M., & Shabani, A. M. H. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.033 · Cited by 120
Metadata
- Venue
- Undergraduate Instrumental Analysis
- Publisher
- CRC Press
- Published
- 2014-07-21
- Pages
- 472-537
- OpenAlex
- W2159889580
- Cited by
- 1,221
- References
- 0
- FWCI
- 92.70
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atomic Absorption Spectrometry. https://app.cochat.ai/papers/10.1201/b15921-10
- The paper
- Atomic Absorption Spectrometry. (2014). Undergraduate Instrumental Analysis. https://doi.org/10.1201/b15921-10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).