Determining Measurement Error in Digital Pedometers
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study was designed to test measurement error in a digital pedometer. Twenty-four Yamax MLS-2000 digital pedometers were tested using a walking test and a shake test before and after heavy use in a large study. The mean deviation from 100 steps for the walking test was 2.26 ± .80 (M ± SD) and 1.71 ± .88 on pretest and posttest, respectively. Mean deviation from 100 shakes for the shake test was 0.39 ± 0.29 and 0.60 ± 0.62 for the pretest and posttest, respectively. No pedometer exceeded 5% error (i.e., 5 steps out of 100) on any of the tests. No significant differences were found between the pretest and posttest, F(1, 46) = 1.49, p ⪈ .229, but significant differences were found between the walking and the shake tests, F(1, 46) = 109.04, p < .01. The interaction was significant, F(1, 46) = 7.76, p £ .008. This study demonstrated that very little measurement error existed in the Yamax MLS-2000 digital pedometer. Researchers can have confidence that the scores obtained using this pedometer are accurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643 · cited 1×
“This inexpensive, objective monitor of daily physical activity is typically used as the dependent measure in studies on both adults and children (Bassett et al., 1996; Eston et al., 1998; Freedson & Miller, 2000; Kilanowski et al., 1999; Welk et al., 2000).”
MethodAccuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Sequeira, M. M., Rickenbach, M., Wietlisbach, V., Tullen, B., & Schutz, Y. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117748 · Cited by 250
Cited by
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Impact of preschool environment upon children's physical activity and sun exposure
Boldemann, C., Blennow, M., Dal, H., Mårtensson, F., Raustorp, A., Yuen, K., & Wester, U. (2006) · Preventive Medicine · doi:10.1016/j.ypmed.2005.12.006 · Cited by 290
Children's Pedometer-Determined Physical Activity during the Segmented School Day
TUDOR-LOCKE, C., LEE, S. M., MORGAN, C. F., BEIGHLE, A., & PANGRAZI, R. P. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000230212.55119.98 · Cited by 284
Rowe, D. A., Mahar, M. T., Raedeke, T. D., & Lore, J. (2004) · Pediatric Exercise Science · doi:10.1123/pes.16.4.343 · Cited by 265
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Metadata
- Authors
- Vincent, S., & Sidman, C.
- Venue
- Measurement in Physical Education and Exercise Science
- Publisher
- Informa UK Limited
- Published
- 2003-03-01
- Volume
- 7
- Issue
- 1
- Pages
- 19-24
- ISSN
- 1091-367X (ISSN-L)
- OpenAlex
- W2003208623
- Cited by
- 131
- References
- 3
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining Measurement Error in Digital Pedometers. https://app.cochat.ai/papers/10.1207/s15327841mpee0701_2
- The paper
- Vincent, S., & Sidman, C. (2003). Determining Measurement Error in Digital Pedometers. Measurement in Physical Education and Exercise Science. https://doi.org/10.1207/s15327841mpee0701_2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.