Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Motion Sensor Accuracy under Controlled and Free-Living Conditions

LE MASURIER, GUY C., LEE, SARAH M., TUDOR-LOCKE, CATRINE·2004·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: Two studies were conducted to examine the concurrent accuracy of the Yamax SW-200 (YAM), Omron HJ-105 (OM), and Sportline 330 (SL) pedometers, as well as a CSA accelerometer. METHODS: In study 1, motion sensor performance was evaluated against actual (observed) steps taken during 5-min bouts at five different treadmill speeds (54, 67, 80, 94, and 107 m x min) using a two-way repeated measures ANOVA (instrument x speed). Additionally, the direction and magnitude of motion sensor error was examined. In study 2, pedometer performance during 24 h of free-living was evaluated against the steps detected by the CSA criterion. The direction and magnitude of pedometer error was also examined in the free-living condition. RESULTS: In study 1, the SL showed significant differences from actual steps taken at all treadmill speeds (P < 0.05). Further, the absolute value of percent error was greatest for the SL at all treadmill speeds. At the slowest treadmill speed (54 m x min), the absolute value of percent error increased for the YAM and OM. In study 2, only the SL detected fewer steps than the CSA criterion (P < 0.05). The YAM demonstrated the lowest absolute value of percent error under free-living conditions. CONCLUSIONS: Different brands of motion sensors detect steps differently; therefore, caution must be used when comparing step counts between studies that have employed different brands of motion sensors. Taking into consideration the results of both studies and the initial walking test used for instrument screening purposes, it appears that, of the three pedometers tested, the YAM pedometer is most consistently accurate under both controlled and free-living conditions. Future research must consider presenting motion sensor accuracy in absolute terms so that the magnitude of error is not underestimated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000126777.50188.73

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 229

Metadata

Authors
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C.
Venue
Medicine & Science in Sports & Exercise
Published
2004-05
Volume
36
Issue
5
Pages
905-910
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2016962446
Cited by
229
References
2
FWCI
7.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion Sensor Accuracy under Controlled and Free-Living Conditions. https://app.cochat.ai/papers/10.1249/01.mss.0000126777.50188.73
The paper
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004). Motion Sensor Accuracy under Controlled and Free-Living Conditions. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000126777.50188.73

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.