Greater in Vivo than in Vitro Pulsatility of Insulin Secretion with Synchronized Insulin and Somatostatin Secretory Pulses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To examine the control of pulsatile insulin secretion by an intrapancreatic pacemaker, samples at minute intervals were taken from the portal vein in dogs in vivo and from an isolated perfused pancreas preparation in vitro. Anesthetized dogs had high amplitude pulsatile insulin secretion which was not consistently regular. Fourier transform analysis showed dominant 20- and 10-min periods of spectral power (P less than 0.01). After vagotomy, the relative oscillatory power was reduced from 83% to 42%, about a lower mean concentration with abolition of the 20-min oscillations. The isolated perfused dog pancreas also had oscillatory insulin secretion with oscillatory power of 12%. Autocorrelation showed regularity of in vitro insulin secretion with a period of 10-11 min (P less than 0.0001). In addition, somatostatin was secreted from the in vitro pancreas in pulses in phase with insulin (cross-correlation P less than 0.0001). These data are in accord with the theory that the pancreas has an internal pacemaker which controls insulin secretion, and that the amplitude of the oscillations is modulated by vagal control. The pacing of the islets may be coordinated by a neural network, whereas coincident pulsatile somatostatin release may temporarily suppress islet secretion and help to synchronize hormonal oscillations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brief, Irregular Oscillations of Basal Plasma Insulin and Glucose Concentrations in Diabetic Man
Lang, D. A., Matthews, D. R., Burnett, M., & Turner, R. C. (1981) · Diabetes · doi:10.2337/diab.30.5.435 · Cited by 279
Self-citation
Cited by
Impaired Pulsatile Secretion of Insulin in Relatives of Patients with Non-Insulin-Dependent Diabetes
O'Rahilly, S., Turner, R. C., & Matthews, D. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181902 · Cited by 540
Self-citationDynamics of insulin secretion and the clinical implications for obesity and diabetes
Seino, S., Shibasaki, T., & Minami, K. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45680 · Cited by 364
Pulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223
“With deconvolution analysis and pulse detection analysis, 40–60 min (64) seems to result in good data whereas regularity statistics (autocorrelation [minimum two times pulse interval] and spectral analysis [N 100]) as well as regularity statistics (approximate entropy: N 40) improve with increased sampling duration (5…”
BackgroundSelf-citationControl Mechanisms of the Oscillations of Insulin Secretion In Vitro and In Vivo
Gilon, P., Ravier, M. A., Jonas, J.-C., & Henquin, J.-C. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s144 · Cited by 168
Farhy, L. S., & McCall, A. L. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400608 · Cited by 13
Metadata
- Authors
- MATTHEWS, D. R., HERMANSEN, K., CONNOLLY, A. A., GRAY, D., SCHMITZ, O., CLARK, A., ORSKOV, H., & TURNER, R. C.
- Venue
- Endocrinology
- Publisher
- The Endocrine Society
- Published
- 1987-06
- Volume
- 120
- Issue
- 6
- Pages
- 2272-2278
- ISSN
- 0013-7227 (ISSN-L)
- 1945-7170
- OpenAlex
- W2110638996
- Cited by
- 41
- References
- 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Greater in Vivo than in Vitro Pulsatility of Insulin Secretion with Synchronized Insulin and Somatostatin Secretory Pulses. https://app.cochat.ai/papers/10.1210/endo-120-6-2272
- The paper
- MATTHEWS, D. R., HERMANSEN, K., CONNOLLY, A. A., GRAY, D., SCHMITZ, O., CLARK, A., ORSKOV, H., & TURNER, R. C. (1987). Greater in Vivo than in Vitro Pulsatility of Insulin Secretion with Synchronized Insulin and Somatostatin Secretory Pulses. Endocrinology. https://doi.org/10.1210/endo-120-6-2272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.