Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays

Preissner, Carol M., O’Kane, Dennis J., Singh, Ravinder J., Morris, John C., Grebe, Stefan K. G.·2003·The Journal of Clinical Endocrinology & Metabolism

Abstract

Serum thyroglobulin (Tg) measurement is a major means of detecting thyroid cancer recurrence. Unlike anti-Tg autoantibody interferences, heterophile antibody (HAB) immunoassay interferences are not well recognized by laboratorians or clinicians as a Tg assay problem. When HAB interferences occur, they usually result in false positive test results. With the current trend to treat some thyroid cancer patients with radioiodine on the basis of an elevated serum Tg result alone, this has the potential to result in unwarranted therapy. We evaluated the prevalence of HAB interference in a commonly used automated immunoassay in 1106 consecutive specimens with Tg values greater than 1 ng/ml. All Tg measurements were repeated after sample incubation in heterophile-blocking tubes (HBT). Results, which showed a more than 3 SD percentage difference from the original result, were considered to suffer from HAB interference. All possible interferences were confirmed by dilution testing. After HBT treatment, Tg levels dropped to less than 1 ng/ml in 32 specimens (P < 0.0000001), 20 of which fell to less than 0.1 ng/ml (P < 0.00002). Of these 20, 17 were anti-Tg autoantibody negative, and all 32 showed a fall of greater than 3 SD percentage (>56.91%) compared with the original result. There were also two samples that showed a significant increase of greater than 56.91% after HBT treatment. HAB interference is relatively prevalent (1.5-3%) in a commonly used automated Tg assay and can lead to clinically significant artifacts. It is currently unknown, but possible, that other immunometric Tg assays suffer from similar problems. Unless a Tg assay is confirmed to be free of HAB interference or uses additional blocking steps, as ours now does, HAB interference should be suspected if Tg results do not fit the clinical picture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2003-030122

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Preissner, C. M., O’Kane, D. J., Singh, R. J., Morris, J. C., & Grebe, S. K. G.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2003-07
Volume
88
Issue
7
Pages
3069-3074
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2048413452
Cited by
197
References
1
FWCI
7.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays. https://app.cochat.ai/papers/10.1210/jc.2003-030122
The paper
Preissner, C. M., O’Kane, D. J., Singh, R. J., Morris, J. C., & Grebe, S. K. G. (2003). Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2003-030122

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.