The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays
Abstract
Serum thyroglobulin (Tg) measurement is a major means of detecting thyroid cancer recurrence. Unlike anti-Tg autoantibody interferences, heterophile antibody (HAB) immunoassay interferences are not well recognized by laboratorians or clinicians as a Tg assay problem. When HAB interferences occur, they usually result in false positive test results. With the current trend to treat some thyroid cancer patients with radioiodine on the basis of an elevated serum Tg result alone, this has the potential to result in unwarranted therapy. We evaluated the prevalence of HAB interference in a commonly used automated immunoassay in 1106 consecutive specimens with Tg values greater than 1 ng/ml. All Tg measurements were repeated after sample incubation in heterophile-blocking tubes (HBT). Results, which showed a more than 3 SD percentage difference from the original result, were considered to suffer from HAB interference. All possible interferences were confirmed by dilution testing. After HBT treatment, Tg levels dropped to less than 1 ng/ml in 32 specimens (P < 0.0000001), 20 of which fell to less than 0.1 ng/ml (P < 0.00002). Of these 20, 17 were anti-Tg autoantibody negative, and all 32 showed a fall of greater than 3 SD percentage (>56.91%) compared with the original result. There were also two samples that showed a significant increase of greater than 56.91% after HBT treatment. HAB interference is relatively prevalent (1.5-3%) in a commonly used automated Tg assay and can lead to clinically significant artifacts. It is currently unknown, but possible, that other immunometric Tg assays suffer from similar problems. Unless a Tg assay is confirmed to be free of HAB interference or uses additional blocking steps, as ours now does, HAB interference should be suspected if Tg results do not fit the clinical picture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibody interference in thyroid assays: a potential for clinical misinformation
Després, N., & Grant, A. M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.440 · Cited by 262
Cited by
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Cooper, D. S., Doherty, G. M., Haugen, B. R., Kloos, R. T., Lee, S. L., Mandel, S. J., Mazzaferri, E. L., McIver, B., Pacini, F., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2009.0110 · Cited by 6,707
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Whiteaker, J. R., Zhao, L., Anderson, L., & Paulovich, A. G. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900254-mcp200 · Cited by 323
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.109652 · Cited by 314
“Serum Tg has long been a thorn in the side of clinical tumor marker immunoassays because of its low concentration and common interferences (8, 10, 11, 13 , 26).”
BackgroundInfluential
Metadata
- Authors
- Preissner, C. M., O’Kane, D. J., Singh, R. J., Morris, J. C., & Grebe, S. K. G.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2003-07
- Volume
- 88
- Issue
- 7
- Pages
- 3069-3074
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2048413452
- Cited by
- 197
- References
- 1
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays. https://app.cochat.ai/papers/10.1210/jc.2003-030122
- The paper
- Preissner, C. M., O’Kane, D. J., Singh, R. J., Morris, J. C., & Grebe, S. K. G. (2003). Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2003-030122
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.