CoChat

Skeletal Muscle Mass in Acromegaly Assessed by Magnetic Resonance Imaging and Dual-Photon X-Ray Absorptiometry

Open access
Freda, Pamela U., Shen, Wei, Reyes-Vidal, Carlos M., Geer, Eliza B., Arias-Mendoza, Fernando, Gallagher, Dympna, Heymsfield, Steven B. · 2009 · The Journal of Clinical Endocrinology & Metabolism
Cited by 66

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Context: GH and IGF-I are nitrogen retaining and anabolic, but the impact of long-term exposure to supraphysiological GH and IGF-I, either from endogenous overproduction in acromegaly or exogenous sources, on skeletal muscle (SM) mass is not clear. Objectives: The objectives of the study were to assess SM mass by whole-body magnetic resonance imaging (MRI) in acromegaly and test the hypothesis that dual-energy x-ray absorptiometry (DXA) lean tissue mass-derived estimates of SM accurately estimate true SM mass. Design, Setting, and Patients: The design was a cross-sectional study in 27 acromegaly patients compared with predicted models developed in 315 nonacromegaly subjects and to matched controls. Outcome Measures: Mass of SM from whole-body MRI and lean tissue from DXA were measured. Results: SM mass did not differ from predicted or control values in active acromegaly: 31.75 ± 8.6 kg (acromegaly) vs. 33.06 ± 8.9 kg (predicted); SM was 95.6 ± 12.8% of predicted (range 66.7–122%) (P = 0.088). Lean tissue mass (DXA) was higher in acromegaly than controls: 65.91 ± 15.2 vs. 58.73 ± 13.5 kg (P < 0.0001). The difference between lean tissue mass (DXA) and SM in acromegaly patients was higher than that in controls (P < 0.0001) consistent with an enlarged non-SM lean compartment in acromegaly. SM mass predicted by DXA correlated highly with SM mass by MRI (r = 0.97, P < 0.0001). SM (MRI) to SM (DXA predicted) ratio was 1.018 (range 0.896–1.159), indicating high agreement of these measures of SM. Conclusions: SM mass in active acromegaly patients did not differ from predicted values. SM mass estimated from DXA agreed highly with SM by MRI, supporting the validity of the DXA model in assessing SM in acromegaly and other disorders of GH/IGF-I secretion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2009-0026

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 66

Metadata

Authors
Freda, P. U., Shen, W., Reyes-Vidal, C. M., Geer, E. B., Arias-Mendoza, F., Gallagher, D., & Heymsfield, S. B.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2009-08-01
Volume
94
Issue
8
Pages
2880-2886
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2106043215
Cited by
66
References
7
FWCI
1.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.