CoChat

The Accuracy of the Glucagon Test Compared to the Insulin Tolerance Test in the Diagnosis of Adrenal Insufficiency in Young Children with Growth Hormone Deficiency

di Iorgi, Natascia, Napoli, Flavia, Allegri, Anna, Secco, Andrea, Calandra, Erika, Calcagno, AnnaLisa, Frassinetti, Costanza, Ghezzi, Michele, Ambrosini, Linda, Parodi, Stefano, Gastaldi, Roberto, Loche, Sandro, Maghnie, Mohamad · 2010 · The Journal of Clinical Endocrinology & Metabolism
Cited by 47

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

CONTEXT: The accuracy of the glucagon test in the diagnosis of central adrenal insufficiency in young children has not yet been definitively established. OBJECTIVE: The aim of this study was to investigate the diagnostic accuracy of the glucagon test as an alternative to the insulin tolerance test (ITT) in children with GH deficiency under 6 yr of age. DESIGN AND SETTING: This was a prospective study conducted in two Pediatric Endocrinology Centers. PATIENTS AND METHODS: Forty-eight children (median age, 4.2 yr) with GH deficiency confirmed by a peak GH to ITT and arginine less than 10 microg/liter were enrolled: 24 with normal hypothalamic-pituitary anatomy, seven with isolated anterior pituitary hypoplasia, and 17 with structural hypothalamic-pituitary abnormalities at magnetic resonance imaging. Twelve subjects had central adrenal insufficiency defined by a peak cortisol response of less than 20 microg/dl to ITT. All children underwent a glucagon stimulation test with blood sampling for cortisol and glucose (time 0 to 180 min) after the im administration of 30 microg/kg of glucagon. RESULTS: The mean peak cortisol after glucagon was not significantly different from that obtained after ITT in the whole cohort (25.9 vs. 26.0 microg/dl; P = 0.908), and it was significantly reduced in patients with structural hypothalamic-pituitary abnormalities (P < 0.001). Receiver operating characteristic curve analysis showed that the best diagnostic accuracy was obtained with a peak cortisol cutoff to glucagon of 14.6 microg/dl (sensitivity, 66.67%; specificity, 100%; area under the curve = 0.91; 95% confidence interval, 0.82-0.99). Using this cutoff, 91.67% of the patients were correctly classified. CONCLUSIONS: This study shows that glucagon is an accurate and safe diagnostic test for adrenal function in young children who are at risk for adrenal insufficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2009-2697

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 47

Metadata

Authors
di Iorgi, N., Napoli, F., Allegri, A., Secco, A., Calandra, E., Calcagno, A., Frassinetti, C., Ghezzi, M., Ambrosini, L., Parodi, S., Gastaldi, R., Loche, S., & Maghnie, M.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2010-05-01
Volume
95
Issue
5
Pages
2132-2139
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2054775954
Cited by
47
References
12
FWCI
1.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Accuracy of the Glucagon Test Compared to the Insulin Tolerance Test in the Diagnosis of Adrenal Insufficiency in Young Children with Growth Hormone Deficiency. https://app.cochat.ai/papers/10.1210/jc.2009-2697
The paper
di Iorgi, N., Napoli, F., Allegri, A., Secco, A., Calandra, E., Calcagno, A., Frassinetti, C., Ghezzi, M., Ambrosini, L., Parodi, S., Gastaldi, R., Loche, S., & Maghnie, M. (2010). The Accuracy of the Glucagon Test Compared to the Insulin Tolerance Test in the Diagnosis of Adrenal Insufficiency in Young Children with Growth Hormone Deficiency. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2009-2697

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.