Diagnostic Accuracy of Copeptin in the Differential Diagnosis of the Polyuria-polydipsia Syndrome: A Prospective Multicenter Study

Timper, Katharina, Fenske, Wiebke, Kühn, Felix, Frech, Nica, Arici, Birsen, Rutishauser, Jonas, Kopp, Peter, Allolio, Bruno, Stettler, Christoph, Müller, Beat, Katan, Mira, Christ-Crain, Mirjam · 2015 · The Journal of Clinical Endocrinology & Metabolism
Cited by 201

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Context: The polyuria-polydipsia syndrome comprises primary polydipsia (PP) and central and nephrogenic diabetes insipidus (DI). Correctly discriminating these entities is mandatory, given that inadequate treatment causes serious complications. The diagnostic “gold standard” is the water deprivation test with assessment of arginine vasopressin (AVP) activity. However, test interpretation and AVP measurement are challenging. Objective: The objective was to evaluate the accuracy of copeptin, a stable peptide stoichiometrically cosecreted with AVP, in the differential diagnosis of polyuria-polydipsia syndrome. Design, Setting, and Patients: This was a prospective multicenter observational cohort study from four Swiss or German tertiary referral centers of adults >18 years old with the history of polyuria and polydipsia. Measurements: A standardized combined water deprivation/3% saline infusion test was performed and terminated when serum sodium exceeded 147 mmol/L. Circulating copeptin and AVP levels were measured regularly throughout the test. Final diagnosis was based on the water deprivation/saline infusion test results, clinical information, and the treatment response. Results: Fifty-five patients were enrolled (11 with complete central DI, 16 with partial central DI, 18 with PP, and 10 with nephrogenic DI). Without prior thirsting, a single baseline copeptin level >21.4 pmol/L differentiated nephrogenic DI from other etiologies with a 100% sensitivity and specificity, rendering a water deprivation testing unnecessary in such cases. A stimulated copeptin >4.9 pmol/L (at sodium levels >147 mmol/L) differentiated between patients with PP and patients with partial central DI with a 94.0% specificity and a 94.4% sensitivity. A stimulated AVP >1.8 pg/mL differentiated between the same categories with a 93.0% specificity and a 83.0% sensitivity. Limitation: This study was limited by incorporation bias from including AVP levels as a diagnostic criterion. Conclusion: Copeptin is a promising new tool in the differential diagnosis of the polyuria-polydipsia syndrome, and a valid surrogate marker for AVP. Primary Funding Sources: Swiss National Science Foundation, University of Basel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2014-4507

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Timper, K., Fenske, W., Kühn, F., Frech, N., Arici, B., Rutishauser, J., Kopp, P., Allolio, B., Stettler, C., Müller, B., Katan, M., & Christ-Crain, M.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2015-06-01
Volume
100
Issue
6
Pages
2268-2274
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1973917022
Cited by
201
References
3
FWCI
8.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.