Diagnostic Accuracy of Copeptin in the Differential Diagnosis of the Polyuria-polydipsia Syndrome: A Prospective Multicenter Study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Context: The polyuria-polydipsia syndrome comprises primary polydipsia (PP) and central and nephrogenic diabetes insipidus (DI). Correctly discriminating these entities is mandatory, given that inadequate treatment causes serious complications. The diagnostic “gold standard” is the water deprivation test with assessment of arginine vasopressin (AVP) activity. However, test interpretation and AVP measurement are challenging. Objective: The objective was to evaluate the accuracy of copeptin, a stable peptide stoichiometrically cosecreted with AVP, in the differential diagnosis of polyuria-polydipsia syndrome. Design, Setting, and Patients: This was a prospective multicenter observational cohort study from four Swiss or German tertiary referral centers of adults >18 years old with the history of polyuria and polydipsia. Measurements: A standardized combined water deprivation/3% saline infusion test was performed and terminated when serum sodium exceeded 147 mmol/L. Circulating copeptin and AVP levels were measured regularly throughout the test. Final diagnosis was based on the water deprivation/saline infusion test results, clinical information, and the treatment response. Results: Fifty-five patients were enrolled (11 with complete central DI, 16 with partial central DI, 18 with PP, and 10 with nephrogenic DI). Without prior thirsting, a single baseline copeptin level >21.4 pmol/L differentiated nephrogenic DI from other etiologies with a 100% sensitivity and specificity, rendering a water deprivation testing unnecessary in such cases. A stimulated copeptin >4.9 pmol/L (at sodium levels >147 mmol/L) differentiated between patients with PP and patients with partial central DI with a 94.0% specificity and a 94.4% sensitivity. A stimulated AVP >1.8 pg/mL differentiated between the same categories with a 93.0% specificity and a 83.0% sensitivity. Limitation: This study was limited by incorporation bias from including AVP levels as a diagnostic criterion. Conclusion: Copeptin is a promising new tool in the differential diagnosis of the polyuria-polydipsia syndrome, and a valid surrogate marker for AVP. Primary Funding Sources: Swiss National Science Foundation, University of Basel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649 · cited 1×
“We then compared the area under the curve (AUC) of copeptin to that of AVP for each diagnosis, using the DeLong Method (16).”
MethodRobertson, G. L., Mahr, E. A., Athar, S., & Sinha, T. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107423 · Cited by 787
Balanescu, S., Kopp, P., Gaskill, M. B., Morgenthaler, N. G., Schindler, C., & Rutishauser, J. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2499 · Cited by 246
Self-citation
Cited by
A Copeptin-Based Approach in the Diagnosis of Diabetes Insipidus
Fenske, W., Refardt, J., Chifu, I., Schnyder, I., Winzeler, B., Drummond, J., Ribeiro-Oliveira, A., Drescher, T., Bilz, S., Vogt, D. R., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1803760 · Cited by 310
Self-citationHigham, C. E., Johannsson, G., & Shalet, S. M. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30053-8 · Cited by 267
Christ-Crain, M., Bichet, D. G., Fenske, W. K., Goldman, M. B., Rittig, S., Verbalis, J. G., & Verkman, A. S. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0103-2 · Cited by 256
Self-citationA randomized controlled trial of the GLP-1 receptor agonist dulaglutide in primary polydipsia
Winzeler, B., Sailer, C. O., Coynel, D., Zanchi, D., Vogt, D. R., Urwyler, S. A., Refardt, J., & Christ-Crain, M. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151800 · Cited by 37
Self-citationRelevance of cortisol and copeptin blood concentration changes in an experimental pain model
Blum, C. A., Velly, L., Brochet, C., Ziegler, F., Tavolacci, M.-P., Hausfater, P., & Lvovschi, V. E. (2022) · Scientific Reports · doi:10.1038/s41598-022-08657-4 · Cited by 8
Metadata
- Authors
- Timper, K., Fenske, W., Kühn, F., Frech, N., Arici, B., Rutishauser, J., Kopp, P., Allolio, B., Stettler, C., Müller, B., Katan, M., & Christ-Crain, M.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2015-06-01
- Volume
- 100
- Issue
- 6
- Pages
- 2268-2274
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W1973917022
- Cited by
- 201
- References
- 3
- FWCI
- 8.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.