CoChat

PRIDE Statement on the Need for a Moratorium on the CMS Plan to Cite Hospitals for Performing Point-of-Care Capillary Blood Glucose Monitoring on Critically Ill Patients

Klonoff, David C., Draznin, Boris, Drincic, Andjela, Dungan, Kathleen, Gianchandani, Roma, Inzucchi, Silvio E., Nichols, James H., Rice, Mark J., Seley, Jane Jeffrie · 2015 · The Journal of Clinical Endocrinology & Metabolism
Cited by 22

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: A writing committee of the Planning Research in Inpatient Diabetes (PRIDE) group has written this consensus article on behalf of the group in response to a specific request for input from the Centers for Medicare and Medicaid Services (CMS). The purpose of this article is to respond to the March 13, 2015 statement from that agency regarding plans to enforce prohibition of the off-label use of point of care (POC) capillary blood glucose monitor (BGM) testing in most critically ill patients. The article discusses: 1) how POC BGM testing is currently regulated; 2) how POC BGM testing is currently used in the United States; and 3) how POC BGM testing can be safely and effectively regulated in the future through cooperation between the clinician, laboratory, regulatory, industry, and patient communities. PARTICIPANTS: Nine members of PRIDE volunteered to write the statement on behalf of the entire group. EVIDENCE: Descriptions of current medical practice for critically ill patients were derived from the experience of the authors. Descriptions of the performance of various methods for measuring glucose levels for intensive insulin therapy came from a literature review. CONSENSUS PROCESS: Eleven questions were developed by the PRIDE writing group. After extensive electronic and telephone discussion, the article was written and reviewed by all nine authors and then reviewed by two outside experts in the care of critically ill patients. All suggestions by the authors and the outside experts were incorporated. CONCLUSIONS: Although the CMS is attempting to protect patients with abnormal glycemic control from harm due to inaccurate POC fingerstick capillary BGM testing, their plan will result in more harm than good. A moratorium on enforcement of the prohibition of off-label use of POC capillary BGM testing is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2015-2435

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 22

Metadata

Authors
Klonoff, D. C., Draznin, B., Drincic, A., Dungan, K., Gianchandani, R., Inzucchi, S. E., Nichols, J. H., Rice, M. J., & Seley, J. J.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2015-10
Volume
100
Issue
10
Pages
3607-3612
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2143048576
Cited by
22
References
2
FWCI
3.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PRIDE Statement on the Need for a Moratorium on the CMS Plan to Cite Hospitals for Performing Point-of-Care Capillary Blood Glucose Monitoring on Critically Ill Patients. https://app.cochat.ai/papers/10.1210/jc.2015-2435
The paper
Klonoff, D. C., Draznin, B., Drincic, A., Dungan, K., Gianchandani, R., Inzucchi, S. E., Nichols, J. H., Rice, M. J., & Seley, J. J. (2015). PRIDE Statement on the Need for a Moratorium on the CMS Plan to Cite Hospitals for Performing Point-of-Care Capillary Blood Glucose Monitoring on Critically Ill Patients. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2015-2435

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.