CoChat

The TSH Response to Thyrotropin-Releasing Hormone (TRH) in Young Adult Men: Intra-Individual Variation and Relation to Basal Serum TSH and Thyroid Hormones

SAWIN, CLARK T., HERSHMAN, JEROME M. · 1976 · The Journal of Clinical Endocrinology & Metabolism
Cited by 72

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The response of serum TSH to duplicate tests with each of two doses of TRH (30 mug and 500 mug) was studied in 22 normal young adult men. The mean intra-individual variability of the response assessed by duplicate testing (coefficient of variation) was 17% but was as high as 63% in individual subjects. While the actual range of peak TSH values after 500 mug TRH was 2.7-19.5 muU/ml, those subjects (3 of 22) with a peak TSH value between 2 and 5 muU/ml on one occasion were all greater than 5 muU/ml on another. Thus, despite the intra-individual variability, a peak TSH value after 500 mug TRH of less than 2 muU/ml indicates TSH deficiency and greater than 5 muU/ml indicates normal TSH reserve. A peak value of 2-5 muU/ml is an indication for retesting;; a peak TSH value greater than 5 muU/ml on retesting indicates normal TSH reserve. The use of the maximal increase in TSH above basal values (max deltaTSH) did not have a clear advantage over the use of the peak TSH value although a max deltaTSH greater than 4 muU/ml was equivalent to a peak value greater than 5 muU/ml. No information was lost by using only the TSH value at 30 min after TRH instead of multiple samples. In using these values differences in assay technique should be considered; for example, the use of human TSH standard MRC 68/38 instead of human TSH standard A (MRC 63/14) causes a fall of about 1/3 in measured serum values. The overall TSH response to 500 mug TRH was statistically greater than the response to 30 mug TRH (P less than 0.01); however, in 10 of 22 subjects the response to the two doses was about the same, suggesting that the dose response of TSH to TRH, between 30 mug and 500 mug TRH, is quite shallow. The TSH value 60 min after 500 mug TRH was within 2 muU/ml of the peak TSH value in 12 of 22 subjects on at least one occasion; this pattern of a delayed fall is a normal variant. The peak TSH response to TRH correlated well with the basal level of TSH (P less than 0.001) and thus can be considered a magnifier of the basal level of TSH in normal subjects. While the peak TSH value did not correlate with the basal level of T3, there was a moderate negative correlation of the peak TSH value with the basal level of T4 (P less than 0.02), suggesting that the concentration of serum T4 within the normal range is a determinant of TSH secretion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem-42-5-809

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
SAWIN, C. T., & HERSHMAN, J. M.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1976-05
Volume
42
Issue
5
Pages
809-816
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1968414325
Cited by
72
References
2
FWCI
7.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.