Improving the Diagnostic Reliability of Rapidly Fluctuating Plasma Hormone Levels by Optimized Multiple-Sampling Techniques
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
When plasma hormone levels undergo rapid and large oscillations, as in the case of testosterone, FSH, and LH, a single random sample is likely to yield a result within +/-20% of the true mean value only 68%, 54%, and 30% of the time, respectively. Multiple sampling increases reliability, and computer analysis demonstrates that three equally-spaced samples taken at 6 to 18 min intervals provide the optimum schedule, given certain practical considerations. Pooling of the three plasma samples prior to radioimmunoassay avoids an increased laboratory workload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Santen, R. J., & Bardin, C. W. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107454 · Cited by 706
Cited by
Steroids in Saliva for Assessing Endocrine Function
RIAD-FAHMY, D., READ, G. F., WALKER, R. F., & GRIFFITHS, K. (1982) · Endocrine Reviews · doi:10.1210/edrv-3-4-367 · Cited by 426
Wallach, E. E., & Goldzieher, J. W. (1981) · Fertility and Sterility · doi:10.1016/s0015-0282(16)45429-4 · Cited by 296
Self-citationAndrogen-Estrogen Metabolism in Women with Upper Body Versus Lower Body Obesity*
KIRSCHNER, M. A., SAMOJLIK, E., DREJKA, M., SZMAL, E., SCHNEIDER, G., & ERTEL, N. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-2-473 · Cited by 292
Dorgan, J., Judd, J., Longcope, C., Brown, C., Schatzkin, A., Clevidence, B., Campbell, W., Nair, P., Franz, C., Kahle, L., et al. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.6.850 · Cited by 181
“trations, Goldzieher et al ( 41 ) estimated that a testosterone”
BackgroundDevelopmental processes in early adolescence
Nottelmann, E. D., Susman, E. J., Dorn, L. D., Inoff-Germain, G., Loriaux, D. L., Cutler, G. B., & Chrousos, G. P. (1987) · Journal of Adolescent Health Care · doi:10.1016/0197-0070(87)90428-1 · Cited by 110
Metadata
- Authors
- GOLDZIEHER, J. W., DOZIER, T. S., SMITH, K. D., & STEINBERGER, E.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1976-10
- Volume
- 43
- Issue
- 4
- Pages
- 824-830
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2009727487
- Cited by
- 102
- References
- 1
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving the Diagnostic Reliability of Rapidly Fluctuating Plasma Hormone Levels by Optimized Multiple-Sampling Techniques. https://app.cochat.ai/papers/10.1210/jcem-43-4-824
- The paper
- GOLDZIEHER, J. W., DOZIER, T. S., SMITH, K. D., & STEINBERGER, E. (1976). Improving the Diagnostic Reliability of Rapidly Fluctuating Plasma Hormone Levels by Optimized Multiple-Sampling Techniques. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-43-4-824
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.