CoChat

Use of a Highly Sensitive and Specific Immunoradiometric Assay for Detection of Human Chorionic Gonadotropin in Urine of Normal, Nonpregnaiit, and Pregnant Individuals*

ARMSTRONG, E. G., EHRLICH, P. H., BIRKEN, S., SCHLATTERER, J. P., SIRIS, E., HEMBREE, W. C., CANFIELD, R. E. · 1984 · The Journal of Clinical Endocrinology & Metabolism
Cited by 106

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A highly sensitive and specific two-site immunoradiometric assay (IRMA) for hCG has been developed and applied to the detection of the hormone in the urine of normal nonpregnant and pregnant individuals. The IRMA uses a solid phase coupled monoclonal antibody to the hCG beta-subunit for extraction of hormone from urine. The hCG extracted is then directly quantified by the binding of an affinity purified and radiolabeled rabbit antibody that reacts with the unique COOH-terminal peptide region of the hCG beta-subunit. The assay is capable of reliably and accurately measuring as little as 0.01 ng hCG/ml urine without interference from hLH. Assays of urine from normal men and nonpregnant women of reproductive age indicated that most individuals did not have detectable levels of hCG immunoreactivity, although a minority had minute amounts, with a mean value of approximately 0.01 ng hCG/mg creatinine. In contrast, all normal menopausal women studied had easily detectable levels of hCG immunoreactivity in their urine, with a mean value of 0.123 ng hCG/mg creatinine. A study of the excretion of hCG from three men injected with hormone for treatment of infertility indicated that after the first 24 h, hCG was cleared with a single exponential rate and was detectable to a level of 0.01 ng/ml. Application of the IRMA to measurements of hCG in the urine of two artificially inseminated patients indicated that the method was capable of detecting pregnancy as early as 9 days postovulation. The extreme sensitivity and specificity of the IRMA for urinary hCG in conjunction with the simplicity of assay performance and specimen collection should provide a substantial advantage over currently available methods for detection of early pregnancy and tumor monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem-59-5-867

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 106

Metadata

Authors
ARMSTRONG, E. G., EHRLICH, P. H., BIRKEN, S., SCHLATTERER, J. P., SIRIS, E., HEMBREE, W. C., & CANFIELD, R. E.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1984-11
Volume
59
Issue
5
Pages
867-874
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2082649881
Cited by
106
References
1
FWCI
11.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a Highly Sensitive and Specific Immunoradiometric Assay for Detection of Human Chorionic Gonadotropin in Urine of Normal, Nonpregnaiit, and Pregnant Individuals*. https://app.cochat.ai/papers/10.1210/jcem-59-5-867
The paper
ARMSTRONG, E. G., EHRLICH, P. H., BIRKEN, S., SCHLATTERER, J. P., SIRIS, E., HEMBREE, W. C., & CANFIELD, R. E. (1984). Use of a Highly Sensitive and Specific Immunoradiometric Assay for Detection of Human Chorionic Gonadotropin in Urine of Normal, Nonpregnaiit, and Pregnant Individuals*. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-59-5-867

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.