Quantitative Digital Radiography Versus Dual Photon Absorptiometry of the Lumbar Spine*
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Lumbar spine bone mineral density (BMD) was measured by quantitative digital radiography, a new dual energy x-ray technique, and by 153Gd dual photon absorptiometry (DPA) in 85 patients. Each patient was measured twice by the new method and once by DPA on the same day, with repositioning between measurements. Serial measurements were made on an hydroxyapatite spine phantom embedded in tissue-equivalent plastic to evaluate the long term reproducibility of each instrument. The spinal BMD measurements with the 2 techniques were linearly related and highly correlated (r = 0.98) over a range from severely osteopenic to high normal. This correlation was not affected by the age, weight, or BMD of the patient measured. Quantitative digital radiography's long-term reproducibility using the spine phantom was stable for 180 days (coefficient of variation, 0.23%); DPA values were 3 times as variable for 170 days (coefficient of variation 0.73%) and increased 1.0% (P less than 0.0001) after a software change. The short term reproducibility of quantitative digital radiography, estimated from paired patient measurements, was 2-fold better than reported values for DPA and was independent of the patient's age, weight, or BMD. Measurement time by quantitative digital radiography was 5-8 min, with a maximum radiation exposure of 3 mrem, significantly lower than the corresponding DPA values. Quantitative digital radiography's image resolution was superior to that of DPA, enabling it to measure more bones. These advantages along with the elimination of 153Gd source changes and Nuclear Regulatory Commission licensing requirements indicate that quantitative digital radiography is the superior method for spinal BMD measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Changes in Bone Mineral Density of the Proximal Femur and Spine with Aging
Riggs, B. L., Wahner, H. W., Seeman, E., Offord, K. P., Dunn, W. L., Mazess, R. B., Johnson, K. A., & Melton, L. J. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110667 · Cited by 816
Cited by
New approaches for interpreting projected bone densitometry data
Professor Carter, D. R., Bouxsein, M. L., & Marcus, R. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070204 · Cited by 1,065
Noninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Genant, H. K., Grampp, S., Glüer, C. C., Faulkner, K. G., Jergas, M., Engelke, K., Hagiwara, S., & van Kuijk, C. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650091002 · Cited by 610
GLASTRE, C., BRAILLON, P., DAVID, L., COCHAT, P., MEUNIER, P. J., & DELMAS, P. D. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-5-1330 · Cited by 590
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Postmenopausal hormone replacement therapy prevents central distribution of body fat after menopause
Haarbo, J., Marslew, U., Gotfredsen, A., & Christiansen, C. (1991) · Metabolism · doi:10.1016/0026-0495(91)90037-w · Cited by 441
Osteopenia in Men with a History of Delayed Puberty
Finkelstein, J. S., Neer, R. M., Biller, B. M. K., Crawford, J. D., & Klibanski, A. (1992) · New England Journal of Medicine · doi:10.1056/nejm199202273260904 · Cited by 439
Self-citationValidation of body composition by dual energy X‐ray absorptiometry (DEXA)
Haarbo, J., Gotfredsen, A., Hassager, C., & Christiansen, C. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00662.x · Cited by 419
Performance evaluation of a dual-energy X-ray bone densitometer
Mazess, R., Collick, B., Trempe, J., Barden, H., & Hanson, J. (1989) · Calcified Tissue International · doi:10.1007/bf02556569 · Cited by 352
Radiation exposure in bone mineral density assessment
Njeh, C. F., Fuerst, T., Hans, D., Blake, G. M., & Genant, H. K. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00026-8 · Cited by 274
Tosteson, A. N. A., Rosenthal, D. I., Melton, L. J., & Weinstein, M. C. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-8-594 · Cited by 221
Bone mineral density measured by dual-energy X-ray absorptiometry in healthy finnish women
Laitinen, K., Välimäki, M., & Keto, P. (1991) · Calcified Tissue International · doi:10.1007/bf02556372 · Cited by 168
“Dual-energy X-ray absorptiometry (DEXA), similar to DPA but showing better resolution and precision and using shorter scanning time [ 6-13 ] has been in-”
MethodInfluentialiDXA, Prodigy, and DPXL Dual-Energy X-ray Absorptiometry Whole-Body Scans: A Cross-Calibration Study
Hull, H., He, Q., Thornton, J., Javed, F., Allen, L., Wang, J., Pierson, R. N., & Gallagher, D. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2008.09.004 · Cited by 113
Heymsfield, S. B., Ebbeling, C. B., Zheng, J., Pietrobelli, A., Strauss, B. J., Silva, A. M., & Ludwig, D. S. (2015) · Obesity Reviews · doi:10.1111/obr.12261 · Cited by 111
“1987 (79) First DXA Systems Introduced for Bone”
BackgroundOsteoporosis Imaging in the Geriatric Patient
Heilmeier, U., Youm, J., Torabi, S., & Link, T. M. (2016) · Current Radiology Reports · doi:10.1007/s40134-016-0144-1 · Cited by 21
“Unlike its predecessor DPA (dual photon absorptiometry), which needed radioactive gadolinium to generate the low-energy photon beams [31], DXA itself uses an X-ray tube to generate two energy X-ray beams of different energies: one ‘‘low-energy’’ X-ray beam of 40 keV and one ‘‘high-energy’’ X-ray beam[70 keV.”
Smoking as a risk factor for bone mineral density in the heel of Japanese men
Hagiwara, S., & Tsumura, K. (1999) · Journal of Clinical Densitometry · doi:10.1385/jcd:2:3:219 · Cited by 8
Metadata
- Authors
- KELLY, T. L., SLOVIK, D. M., SCHOENFELD, D. A., & NEER, R. M.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1988-10
- Volume
- 67
- Issue
- 4
- Pages
- 839-844
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2001374121
- Cited by
- 214
- References
- 1
- FWCI
- 22.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.