Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 239

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Vitamin K Status and Bone Health: An Analysis of Methods for Determination of Undercarboxylated Osteocalcin1

Gundberg, Caren M., Nieman, Sherril D., Abrams, Steven, Rosen, Harold · 1998 · The Journal of Clinical Endocrinology & Metabolism

Abstract

Recent studies suggest that fracture risk is associated with increased undercarboxylated osteocalcin. Methods use differences in binding of undercarboxylated and fully carboxylated osteocalcin to hydroxyapatite or barium sulfate. We evaluated these methods and found that results varied with the amount and preparation of the salts. Furthermore, patient samples with differing amounts of total osteocalcin could not be directly compared. Errors in the determination of undercarboxylated osteocalcin were minimized by expressing data as the percent of the total osteocalcin in the sample, and correcting for the basal level of osteocalcin using a polynomial equation derived from multiple binding curves. Errors from 5–15% in estimation of undercarboxylated osteocalcin were observed without both of these corrections. When differing types of assays were employed (RIA, intact, N-terminal), results also were affected. In normal adults and children and in patients on long-term warfarin therapy, the percent osteocalcin not bound to hydroxyapatite was lower when measured with an intact assay than by a polyclonal RIA. Differences were related to the amount of N-terminal osteocalcin fragments, which had low affinity for hydroxyapatite and resulted in variable overestimation of undercarboxylated osteocalcin. In a kit specific for uncarboxylated osteocalcin, we found good discrimination between carboxylated and uncarboxylated intact osteocalcin. However, the assay detected large osteocalcin fragments and overestimated their concentration by up to 350%. Values for uncarboxylated osteocalcin were not different in patients on coumadin compared with normal adults with this kit, but when normalized to the total intact osteocalcin, percent uncarboxylated osteocalcin was greater in patients on coumadin than in controls, as would be expected. Kit values for uncarboxylated osteocalcin in normal children were higher than intact values in the same subject, because of the increased reactivity of the kit toward circulating fragments that were elevated in children. Thus, for estimation of undercarboxylated osteocalcin, care must be taken to standardize the hydroxyapatite or barium sulfite used for binding, to correct for the basal level of osteocalcin in the sample, to use immunoassays that do not detect small fragments, and to express the results as the percent of the total osteocalcin in the sample. Without these precautions, the assessment of undercarboxylated osteocalcin is not reliable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem.83.9.5126

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 239

Metadata

Authors
Gundberg, C. M., Nieman, S. D., Abrams, S., & Rosen, H.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1998-09-01
Volume
83
Issue
9
Pages
3258-3266
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2004115712
Cited by
239
References
2
FWCI
4.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.