The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Size-dependent disposition of nanoparticles and microparticles following subconjunctival administration
Abstract
The purpose of this study was to determine the retention and ocular distribution of subconjunctivally administered nanoparticles and microparticles. Fluorescent polystyrene particles (carboxylate modified, negatively charged) of various sizes (20 nm, 200 nm and 2 μm; Fluospheres, dose 400 μg) were administered to male Sprague-Dawley rats by subconjunctival injection under anaesthesia. The disposition of the particles in the periocular and ocular tissues was studied for up to 60 days by quantifying the particle amounts using liquid extraction followed by spectrofluorimetric analysis. The effect of dose on the particle disposition was investigated with a 40-μg dose of the particles. The effect of an increase in surface hydrophobicity was evaluated for the 20 and 200 nm particles at 1 day post administration. Following periocular administration, penetration into the ocular tissues was negligible for the carboxylate-modified microparticles as well as nanoparticles. Almost the entire dose of the 200 nm and 2 μm particles was retained in the periocular tissue at 60 days post-administration. The 20 nm particles disappeared rapidly from the periocular tissue with 15 and 8% of administered dose remaining after 1 and 7 days, respectively. The 20 nm particles could not be detected in the periocular tissue at 60-days post-administration. An increase in the surface hydrophobicity did not affect the periocular retention of 200 nm particles but elevated that of the 20 nm particles, at the end of day 1. It was concluded that subconjunctivally administered 200 nm and larger particles can be almost completely retained at the site of administration for at least two months. Periocular administration of particulate systems of this size would likely be useful as sustained drug delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Periocular routes for retinal drug delivery
Raghava, S., Hammond, M., & Kompella, U. B. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.99 · Cited by 257
Self-citation
Cited by
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
Ocular drug delivery systems: An overview
Patel, A. (2013) · World Journal of Pharmacology · doi:10.5497/wjp.v2.i2.47 · Cited by 890
Nanotechnology-based strategies for treatment of ocular disease
Weng, Y., Liu, J., Jin, S., Guo, W., Liang, X., & Hu, Z. (2017) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2016.09.001 · Cited by 375
Nanocarriers for ocular drug delivery: current status and translational opportunity
Gorantla, S., Rapalli, V. K., Waghule, T., Singh, P. P., Dubey, S. K., Saha, R. N., & Singhvi, G. (2020) · RSC Advances · doi:10.1039/d0ra04971a · Cited by 313
Metadata
- Authors
- Amrite, A. C., & Kompella, U. B.
- Venue
- Journal of Pharmacy and Pharmacology
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-12-01
- Volume
- 57
- Issue
- 12
- Pages
- 1555-1563
- ISSN
- 0022-3573 (ISSN-L)
- 2042-7158
- OpenAlex
- W2030067645
- Cited by
- 212
- References
- 1
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size-dependent disposition of nanoparticles and microparticles following subconjunctival administration. https://app.cochat.ai/papers/10.1211/jpp.57.12.0005
- The paper
- Amrite, A. C., & Kompella, U. B. (2005). Size-dependent disposition of nanoparticles and microparticles following subconjunctival administration. Journal of Pharmacy and Pharmacology. https://doi.org/10.1211/jpp.57.12.0005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.