The DOI matches its Crossref record.
3T phased array MRI improves the presurgical evaluation in focal epilepsies: A prospective study
Abstract
BACKGROUND: Although detection of concordant lesions on MRI significantly improves postsurgical outcomes in focal epilepsy (FE), many conventional MR studies remain negative. The authors evaluated the role of phased array surface coil studies performed at 3 Tesla (3T PA MRI). METHODS: Forty patients with medically intractable focal epilepsies were prospectively imaged with 3T PA-MRI including high matrix TSE T2, fluid attenuated inversion recovery, and magnetization prepared rapid gradient echo. All patients were considered candidates for epilepsy surgery. 3T PA-MRIs were reviewed by a neuroradiologist experienced in epilepsy imaging with access to clinical information. Findings were compared to reports of prior standard 1.5T MRI epilepsy studies performed at tertiary care centers. RESULTS: Experienced, unblinded review of 3T PA-MRI studies yielded additional diagnostic information in 48% (19/40) compared to routine clinical reads at 1.5T. In 37.5% (15/40), this additional information motivated a change in clinical management. In the subgroup of patients with prior 1.5T MRIs interpreted as normal, 3T PA-MRI resulted in the detection of a new lesion in 65% (15/23). In the subgroup of 15 patients with known lesions, 3T PA-MRI better defined the lesion in 33% (5/15). CONCLUSION: Phased array surface coil studies performed at 3 Tesla read by an experienced unblinded neuroradiologist can improve the presurgical evaluation of patients with focal epilepsy when compared to routine clinical 1.5T studies read at tertiary care centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bernasconi, A., Cendes, F., Theodore, W. H., Gill, R. S., Koepp, M. J., Hogan, R. E., Jackson, G. D., Federico, P., Labate, A., Vaudano, A. E., et al. (2019) · Epilepsia · doi:10.1111/epi.15612 · Cited by 502
Brain imaging in the assessment for epilepsy surgery
Duncan, J. S., Winston, G. P., Koepp, M. J., & Ourselin, S. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00383-x · Cited by 363
Advances in MRI for 'cryptogenic' epilepsies
Bernasconi, A., Bernasconi, N., Bernhardt, B. C., & Schrader, D. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.199 · Cited by 233
Imaging in the surgical treatment of epilepsy
Duncan, J. S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.131 · Cited by 219
The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2500-8 · Cited by 94
Metadata
- Authors
- Knake, S., Triantafyllou, C., Wald, L. L., Wiggins, G., Kirk, G. P., Larsson, P. G., Stufflebeam, S. M., Foley, M. T., Shiraishi, H., Dale, A. M., Halgren, E., & Grant, P. E.
- Venue
- Neurology
- Published
- 2005-10-11
- Volume
- 65
- Issue
- 7
- Pages
- 1026-1031
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2160310295
- Cited by
- 225
- References
- 0
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3T phased array MRI improves the presurgical evaluation in focal epilepsies: A prospective study. https://app.cochat.ai/papers/10.1212/01.wnl.0000179355.04481.3c
- The paper
- Knake, S., Triantafyllou, C., Wald, L. L., Wiggins, G., Kirk, G. P., Larsson, P. G., Stufflebeam, S. M., Foley, M. T., Shiraishi, H., Dale, A. M., Halgren, E., & Grant, P. E. (2005). 3T phased array MRI improves the presurgical evaluation in focal epilepsies: A prospective study. Neurology. https://doi.org/10.1212/01.wnl.0000179355.04481.3c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.