The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hippocampal electrical stimulation in mesial temporal lobe epilepsy
Abstract
BACKGROUND: Adjustable, reversible therapies are needed for patients with pharmacoresistant epilepsy. Electrical stimulation of the hippocampus has been proposed as a possible treatment for mesial temporal lobe epilepsy (MTLE). METHODS: Four patients with refractory MTLE whose risk to memory contraindicated temporal lobe resection underwent implantation of a chronic stimulating depth electrode along the axis of the left hippocampus. The authors used continuous, subthreshold electrical stimulation (90 microsec, 190 Hz) and a double blind, multiple cross-over, randomized controlled design, consisting of three treatment pairs, each containing two 1-month treatment periods. During each treatment pair the stimulator was randomly turned ON 1 month and OFF 1 month. Outcomes were assessed at monthly intervals in a double blind manner, using standardized instruments and accounting for a washout period. The authors compared outcomes between ON, OFF, and baseline periods. RESULTS: Hippocampal stimulation produced a median reduction in seizures of 15%. All but one patient's seizures improved; however, the results did not reach significance. Effects seemed to carry over into the OFF period, and an implantation effect cannot be ruled out. The authors found no significant differences in other outcomes. There were no adverse effects. One patient has been treated for 4 years and continues to experience substantial long-term seizure improvement. CONCLUSION: The authors demonstrate important beneficial trends, some long-term benefits, and absence of adverse effects of hippocampal electrical stimulation in mesial temporal lobe epilepsy. However, the effect sizes observed were smaller than those reported in non-randomized, unblinded studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wechsler Adult Intelligence Scale--Third Edition
Wechsler, D. (2019) · PsycTESTS Dataset · doi:10.1037/t49755-000 · Cited by 2,327
Benedict, R. H. B., Schretlen, D., Groninger, L., & Brandt, J. (1998) · The Clinical Neuropsychologist · doi:10.1076/clin.12.1.43.1726 · Cited by 1,597
Cited by
Deep Brain Stimulation in Patients with Refractory Temporal Lobe Epilepsy
Boon, P., Vonck, K., De Herdt, V., Van Dycke, A., Goethals, M., Goossens, L., Van Zandijcke, M., De Smedt, T., Dewaele, I., Achten, R., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01005.x · Cited by 368
Velasco, A. L., Velasco, F., Velasco, M., Trejo, D., Castro, G., & Carrillo‐Ruiz, J. D. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01181.x · Cited by 331
Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330
Geller, E. B., Skarpaas, T. L., Gross, R. E., Goodman, R. R., Barkley, G. L., Bazil, C. W., Berg, M. J., Bergey, G. K., Cash, S. S., Cole, A. J., et al. (2017) · Epilepsia · doi:10.1111/epi.13740 · Cited by 310
Deep brain stimulation for drug‐resistant epilepsy
Li, M. C. H., & Cook, M. J. (2018) · Epilepsia · doi:10.1111/epi.13964 · Cited by 293
Metadata
- Authors
- Tellez-Zenteno, J. F., McLachlan, R. S., Parrent, A., Kubu, C. S., & Wiebe, S.
- Venue
- Neurology
- Published
- 2006-05
- Volume
- 66
- Issue
- 10
- Pages
- 1490-1494
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2017549188
- Cited by
- 246
- References
- 2
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hippocampal electrical stimulation in mesial temporal lobe epilepsy. https://app.cochat.ai/papers/10.1212/01.wnl.0000209300.49308.8f
- The paper
- Tellez-Zenteno, J. F., McLachlan, R. S., Parrent, A., Kubu, C. S., & Wiebe, S. (2006). Hippocampal electrical stimulation in mesial temporal lobe epilepsy. Neurology. https://doi.org/10.1212/01.wnl.0000209300.49308.8f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.