Influence of magnetic source imaging for planning intracranial EEG in epilepsy
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Magnetic source imaging (MSI) is used routinely in epilepsy presurgical evaluation and in mapping eloquent cortex for surgery. Despite increasing use, the diagnostic yield of MSI is uncertain, with reports varying from 5% to 35%. To add benefit, a diagnostic technique should influence decisions made from other tests, and that influence should yield better outcomes. We report preliminary results of an ongoing, long-term clinical study in epilepsy, where MSI changed surgical decisions. METHODS: We determined whether MSI changed the surgical decision in a prospective, blinded, crossover-controlled, single-treatment, observational case series. Sixty-nine sequential patients diagnosed with partial epilepsy of suspected neocortical origin had video-EEG and imaging. All met criteria for intracranial EEG (ICEEG). At a surgical conference, a decision was made before and after presentation of MSI. Cases where MSI altered the decision were noted. RESULTS: MSI gave nonredundant information in 23 patients (33%). MSI added ICEEG electrodes in 9 (13%) and changed the surgical decision in another 14 (20%). Based on MSI, 16 patients (23%) were scheduled for different ICEEG coverage. Twenty-eight have gone to ICEEG, 29 to resection, and 14 to vagal nerve stimulation, including 17 where MSI changed the decision. Additional electrodes in 4 patients covered the correct: hemisphere in 3, lobe in 3, and sublobar ictal onset zone in 1. MSI avoided contralateral electrodes in 2, who both localized on ICEEG. MSI added information to ICEEG in 1. CONCLUSION: Magnetic source imaging (MSI) provided nonredundant information in 33% of patients. In those who have undergone surgery to date, MSI added useful information that changed treatment in 6 (9%), without increasing complications. MSI has benefited 21% who have gone to surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ictal localization of temporal lobe seizures with scalp/sphenoidal recordings
Risinger, M. W., Engel, J., Van Ness, P. C., Henry, T. R., & Crandall, P. H. (1989) · Neurology · doi:10.1212/wnl.39.10.1288 · Cited by 347
Engel, J., Henry, T. R., Risinger, M. W., Mazziotta, J. C., Sutherling, W. W., Levesque, M. F., & Phelps, M. E. (1990) · Neurology · doi:10.1212/wnl.40.11.1670 · Cited by 316
Self-citationMagnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Engel, J., Rausch, R., Lieb, J. P., Kuhl, D. E., & Crandall, P. H. (1981) · Annals of Neurology · doi:10.1002/ana.410090303 · Cited by 297
Sobel, D. F., Gallen, C. C., Schwartz, B. J., Waltz, T. A., Copeland, B. R., Yamada, S., Hirschkoff, E. C., & Bloom, F. E. (1993) · PubMed · Cited by 202
Comparisons of MEG, EEG, and ECoG source localization in neocortical partial epilepsy in humans
Nakasatp, N., Levesque, M. F., Barth, D. S., Baumgartner, C., Rogers, R. L., & Sutherling, W. W. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90067-1 · Cited by 194
Self-citationA Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., et al. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00800.x · Cited by 193
Magnetoencephalographic mapping of the language-specific cortex
Papanicolaou, A. C., Simos, P. G., Breier, J. I., Zouridakis, G., Willmore, L. J., Wheless, J. W., Constantinou, J. E. C., Maggio, W. W., & Gormley, W. B. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.1.0085 · Cited by 178
Magnetoencephalographic mapping of the language-specific cortex
Papanicolaou, A. C., Simos, P. G., Breier, J. I., Zouridakis, G., Willmore, L. J., Wheless, J. W., Constantinou, J. E. C., Maggio, W. W., & Gormley, W. B. (1998) · Neurosurgical Focus · doi:10.3171/foc.1998.5.5.2 · Cited by 176
Knowlton, R. C., Elgavish, R., Howell, J., Blount, J., Burneo, J. G., Faught, E., Kankirawatana, P., Riley, K., Morawetz, R., Worthington, J., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20857 · Cited by 169
The value of multichannel MEG and EEG in the presurgical evaluation of 70 epilepsy patients
Knake, S., Halgren, E., Shiraishi, H., Hara, K., Hamer, H. M., Grant, P. E., Carr, V. A., Foxe, D., Camposano, S., Busa, E., et al. (2006) · Epilepsy Research · doi:10.1016/j.eplepsyres.2006.01.001 · Cited by 165
Magnetoencephalography/Magnetic Source Imaging in the Assessment of Patients with Epilepsy
Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb04533.x · Cited by 118
Does magnetoencephalography add to scalp video-EEG as a diagnostic tool in epilepsy surgery?
Pataraia, E., Simos, P. G., Castillo, E. M., Billingsley, R. L., Sarkari, S., Wheless, J. W., Maggio, V., Maggio, W., Baumgartner, J. E., Swank, P. R., et al. (2004) · Neurology · doi:10.1212/01.wnl.0000115122.81621.fe · Cited by 117
Magnetoencephalography-directed surgery in patients with neocortical epilepsy
Mamelak, A. N., López, N., Akhtari, M., et al. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.97.4.0865 · Cited by 114
Self-citationSurgical Implications of Neuromagnetic Spike Localization in Temporal Lobe Epilepsy
Iwasaki, M., Nakasato, N., Shamoto, H., Nagamatsu, K., Kanno, A., Hatanaka, K., & Yoshimoto, T. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.30801.x · Cited by 109
Does magnetoencephalography add to scalp video-EEG as a diagnostic tool in epilepsy surgery?
Lüders, H. O., & Iwasaki, M. (2004) · Neurology · doi:10.1212/wnl.63.10.1987 · Cited by 97
Localization of magnetic interictal discharges in temporal lobe epilepsy
Rose, D. F., Sato, S., Smith, P. D., Porter, R. J., Theodore, W. H., Friauf, W. S., Bonner, R. F., & Jabbari, B. (1987) · Annals of Neurology · doi:10.1002/ana.410220311 · Cited by 81
Magnetoencephalography in presurgical epilepsy evaluation
Pataraia, E., Baumgartner, C., Lindinger, G., & Deecke, L. (2002) · Neurosurgical Review · doi:10.1007/s10143-001-0197-2 · Cited by 80
Leijten, F. S. S., Huiskamp, G. J. M., Hilgersom, I., & van Huffelen, A. C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00001 · Cited by 79
Magnetoencephalography source localization and surgical outcome in temporal lobe epilepsy
Assaf, B. A., Karkar, K. M., Laxer, K. D., Garcia, P. A., Austin, E. J., Barbaro, N. M., & Aminoff, M. J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.020 · Cited by 68
Neuromagnetic mapping of brain function.
Gallen, C. C., Sobel, D. F., Lewine, J. D., Sanders, J. A., Hart, B. L., Davis, L., & Orrison, W. W. (1993) · Radiology · doi:10.1148/radiology.187.3.8497647 · Cited by 49
Sutherling, W. W., Akhtari, M., Mamelak, A. N., Mosher, J. C., Arthur, D., Sands, S. A., Weiss, P., López, N., DiMauro, M., Flynn, E. R., et al. (2001) · Brain Topography · doi:10.1023/a:1012940812742 · Cited by 44
Self-citationA hemispherically asymmetrical MEG response to vowels
Szymanski, M. D., Rowley, H. A., & Roberts, T. P. L. (1999) · Neuroreport · doi:10.1097/00001756-199908200-00009 · Cited by 38
Depth Recordings in Man in Temporal Lobe Epilepsy
Buser, P., Bancaud, J., & Talairach, J. (1973) · UCLA forum in medical sciences · doi:10.1016/b978-0-12-128650-7.50010-x · Cited by 36
Magnetoencephalography: Clinical application in epilepsy
Knowlton, R. C. (2003) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-003-0012-2 · Cited by 17
Cited by
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“…localization studies in epilepsy [particularly those using magnetoencephalography (MEG)] utilize spherical head models and subsequent co-registration of equiva- lent dipoles with the patient’s MRI using simple fiducial-based matching methods (e.g. Sutherling et al., 2008; Knowlton et al., 2009).”
MethodMagnetoencephalography: Basic principles
Singh, S. (2014) · Annals of Indian Academy of Neurology · doi:10.4103/0972-2327.128676 · Cited by 206
“Sutherling et al.[8] studied where MSI changed surgical decisions.”
Role of subdural electrocorticography in prediction of long-term seizure outcome in epilepsy surgery
Asano, E., Juhász, C., Shah, A., Sood, S., & Chugani, H. T. (2009) · Brain · doi:10.1093/brain/awp025 · Cited by 175
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“The MEG findings can for example change the plan for intra-cranial electrode implantation and alter the surgical plan itself (Sutherling et al., 2008; The AAN Board of Directors, 2009; Knowlton et al., 2009).”
BackgroundMagnetoencephalography for epileptic focus localization in a series of 1000 cases
Rampp, S., Stefan, H., Wu, X., Kaltenhäuser, M., Maess, B., Schmitt, F. C., Wolters, C. H., Hamer, H., Kasper, B. S., Schwab, S., et al. (2019) · Brain · doi:10.1093/brain/awz231 · Cited by 163
Metadata
- Authors
- Sutherling, W. W., Mamelak, A. N., Thyerlei, D., Maleeva, T., Minazad, Y., Philpott, L., & Lopez, N.
- Venue
- Neurology
- Published
- 2008-09-23
- Volume
- 71
- Issue
- 13
- Pages
- 990-996
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2080478044
- Cited by
- 177
- References
- 25
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.