Value of the central vein sign at 3T to differentiate MS from seropositive NMOSD
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objective To assess the value of the central vein sign (CVS) on a clinical 3T scanner to distinguish between multiple sclerosis (MS) and neuromyelitis optica spectrum disorder (NMOSD). Methods Eighteen aquaporin-4-antibody-positive patients with NMOSD, 18 patients with relapsing-remitting MS, and 25 healthy controls underwent 3T MRI. The presence of a central vein in white matter lesions on susceptibility-weighted imaging, defined as a thin hypointense line or a small dot, was recorded. Results The proportion of lesions with the CVS was higher in MS than NMOSD (80% vs 32%, p < 0.001). A greater proportion of lesions with the CVS predicted the diagnosis of MS, rather than NMOSD (odds ratio 1.10, 95% confidence interval [CI] 1.04 to 1.16, p = 0.001), suggesting that each percent unit increase in the proportion of lesions with the CVS in an individual patient was associated with a 10% increase in the risk of the same patient having MS. If more than 54% of the lesions on any given scan show the CVS, then the patient can be given a diagnosis of MS with an accuracy of 94% (95% CIs 81.34, 99.32, p < 0.001, sensitivity/specificity 90%/100%). Conclusion The clinical value of the CVS in the context of the differential diagnosis between MS and NMOSD, previously suggested using 7T scanners, is now extended to clinical 3T scanners, thereby making a step towards the use of CVS in clinical practice. Classification of evidence This study provides Class III evidence that the CVS on 3T MRI accurately distinguishes patients with MS from those with seropositive NMOSD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802
International consensus diagnostic criteria for neuromyelitis optica spectrum disorders
Wingerchuk, D. M., Banwell, B., Bennett, J. L., Cabre, P., Carroll, W., Chitnis, T., de Seze, J., Fujihara, K., Greenberg, B., Jacob, A., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001729 · Cited by 4,649 · cited 1×
“MRI has an important role in the diagnosis of neuromyelitis optica spectrum disorder (NMOSD) and multiple sclerosis (MS).(1) The differentiation between the 2 diseases is often challenging, since clinical manifestations may overlap, and up to 70% of patients with NMOSD have brain lesions on MRI.”
BackgroundSelf-citationSTARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 1×
“com/WNL/A310) shows the flow diagram of patients.(19) This cutoff indicates that if more than 54% of the white matter lesions seen on any given scan show the CVS, then the patient can be given a diagnosis of MS.”
BackgroundDefining the clinical course of multiple sclerosis: The 2013 revisions
Lublin, F. D., Reingold, S. C., Cohen, J. A., Cutter, G. R., Sørensen, P. S., Thompson, A. J., Wolinsky, J. S., Balcer, L. J., Banwell, B., Barkhof, F., et al. (2014) · Neurology · doi:10.1212/wnl.0000000000000560 · Cited by 3,177
Self-citationMRI characteristics of neuromyelitis optica spectrum disorder: An international update
Kim, H. J., Paul, F., Lana-Peixoto, M. A., Tenembaum, S., Asgari, N., Palace, J., Klawiter, E. C., Sato, D. K., de Seze, J., Wuerfel, J., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001367 · Cited by 664 · cited 6×
“The differentiation between the 2 diseases is often challenging, since clinical manifestations may overlap, and up to 70% of patients with NMOSD have brain lesions on MRI.(2) An accurate differentiation between these 2 diseases is crucial, because some MS therapies cause disease worsening in NMOSD.”
BackgroundInfluentialSelf-citationon behalf of the MAGNIMS study group, Rovira, À., Wattjes, M. P., Tintoré, M., Tur, C., Yousry, T. A., Sormani, M. P., De Stefano, N., Filippi, M., Auger, C., et al. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.106 · Cited by 423
Self-citationDistinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
Sinnecker, T., Dörr, J., Pfueller, C. F., Harms, L., Ruprecht, K., Jarius, S., Brück, W., Niendorf, T., Wuerfel, J., & Paul, F. (2012) · Neurology · doi:10.1212/wnl.0b013e3182648bc8 · Cited by 214 · cited 1×
“We have validated the use of the CVS to support the differential diagnosis between MS and NMOSD by using a clinical 3T scanner, thereby extending early results obtained at 7T.(8,9) We found that the presence of ≥54% of white matter lesions with the CVS predicted a diagnosis of MS with a high accuracy, high sensitivity…”
MethodUltrahigh-Field MR (7 T) Imaging of Brain Lesions in Neuromyelitis Optica
Kister, I., Herbert, J., Zhou, Y., & Ge, Y. (2013) · Multiple Sclerosis International · doi:10.1155/2013/398259 · Cited by 75
Cited by
Wattjes, M. P., Ciccarelli, O., Reich, D. S., Banwell, B., de Stefano, N., Enzinger, C., Fazekas, F., Filippi, M., Frederiksen, J., Gasperini, C., et al. (2021) · The Lancet Neurology · doi:10.1016/s1474-4422(21)00095-8 · Cited by 674
Self-citationAssessment of lesions on magnetic resonance imaging in multiple sclerosis: practical guidelines
Filippi, M., Preziosa, P., Banwell, B. L., Barkhof, F., Ciccarelli, O., De Stefano, N., Geurts, J. J. G., Paul, F., Reich, D. S., Toosy, A. T., et al. (2019) · Brain · doi:10.1093/brain/awz144 · Cited by 560
Self-citationAssociation between pathological and MRI findings in multiple sclerosis
Filippi, M., Brück, W., Chard, D., Fazekas, F., Geurts, J. J. G., Enzinger, C., Hametner, S., Kuhlmann, T., Preziosa, P., Rovira, À., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30451-4 · Cited by 253
Jarius, S., Aktas, O., Ayzenberg, I., Bellmann-Strobl, J., Berthele, A., Giglhuber, K., Häußler, V., Havla, J., Hellwig, K., Hümmert, M. W., et al. (2023) · Journal of Neurology · doi:10.1007/s00415-023-11634-0 · Cited by 231
“, 7-T MRI, central vein sign, diffusion tensor imaging) for diagnosis, differential diagnosis, and disease monitoring remains to be evaluated [29, 118, 120, 198].”
BackgroundEvaluation of the Central Vein Sign as a Diagnostic Imaging Biomarker in Multiple Sclerosis
Sinnecker, T., Clarke, M. A., Meier, D., Enzinger, C., Calabrese, M., De Stefano, N., Pitiot, A., Giorgio, A., Schoonheim, M. M., Paul, F., et al. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.2478 · Cited by 215
Metadata
- Authors
- Cortese, R., Magnollay, L., Tur, C., Abdel-Aziz, K., Jacob, A., De Angelis, F., Yiannakas, M. C., Prados, F., Ourselin, S., Yousry, T. A., Barkhof, F., & Ciccarelli, O.
- Venue
- Neurology
- Published
- 2018-04-03
- Volume
- 90
- Issue
- 14
- Pages
- e1183-e1190
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2771783187
- Cited by
- 105
- References
- 8
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Value of the central vein sign at 3T to differentiate MS from seropositive NMOSD. https://app.cochat.ai/papers/10.1212/wnl.0000000000005256
- The paper
- Cortese, R., Magnollay, L., Tur, C., Abdel-Aziz, K., Jacob, A., De Angelis, F., Yiannakas, M. C., Prados, F., Ourselin, S., Yousry, T. A., Barkhof, F., & Ciccarelli, O. (2018). Value of the central vein sign at 3T to differentiate MS from seropositive NMOSD. Neurology. https://doi.org/10.1212/wnl.0000000000005256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.