Interim Safety Profile From the Feasibility Study of the BrainGate Neural Interface System
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVES: Brain-computer interfaces (BCIs) are being developed to restore mobility, communication, and functional independence to people with paralysis. Though supported by decades of preclinical data, the safety of chronically implanted microelectrode array BCIs in humans is unknown. We report safety results from the prospective, open-label, nonrandomized BrainGate feasibility study (NCT00912041), the largest and longest-running clinical trial of an implanted BCI. METHODS: Adults aged 18-75 years with quadriparesis from spinal cord injury, brainstem stroke, or motor neuron disease were enrolled through 7 clinical sites in the United States. Participants underwent surgical implantation of 1 or 2 microelectrode arrays in the motor cortex of the dominant cerebral hemisphere. The primary safety outcome was device-related serious adverse events (SAEs) requiring device explantation or resulting in death or permanently increased disability during the 1-year postimplant evaluation period. The secondary outcomes included the type and frequency of other adverse events and the feasibility of the BrainGate system for controlling a computer or other assistive technologies. RESULTS: From 2004 to 2021, 14 adults enrolled in the BrainGate trial had devices surgically implanted. The average duration of device implantation was 872 days, yielding 12,203 days of safety experience. There were 68 device-related adverse events, including 6 device-related SAEs. The most common device-related adverse event was skin irritation around the percutaneous pedestal. There were no safety events that required device explantation, no unanticipated adverse device events, no intracranial infections, and no participant deaths or adverse events resulting in permanently increased disability related to the investigational device. DISCUSSION: The BrainGate Neural Interface system has a safety record comparable with other chronically implanted medical devices. Given rapid recent advances in this technology and continued performance gains, these data suggest a favorable risk/benefit ratio in appropriately selected individuals to support ongoing research and development. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov Identifier: NCT00912041. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that the neurosurgically placed BrainGate Neural Interface system is associated with a low rate of SAEs defined as those requiring device explantation, resulting in death, or resulting in permanently increased disability during the 1-year postimplant period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Intracortical MEA recordings are used to measure neural activity at the level of single neurons or neuron clusters83.”
From The speech neuroprosthesis (2024) · cites this paper as [83]
The cited source says what the claim attributes to it.
In the citing paper
“although recent safety data are encouraging34”
From A high-performance speech neuroprosthesis (2023) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“(7) Brain machine interfaces incorporating neural population dynamics.”
BackgroundSelf-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
Self-citationBacterial Meningitis in the United States, 1998–2007
Thigpen, M. C., Whitney, C. G., Messonnier, N. E., Zell, E. R., Lynfield, R., Hadler, J. L., Harrison, L. H., Farley, M. M., Reingold, A., Bennett, N. M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1005384 · Cited by 953
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Self-citation
Research works printed but not linked: 1
- Hochberg LR, Anderson K. BCI users and their needs. In: Wolpaw JR, Wolpaw E, eds. Brain-Computer Interfaces: Principles and Practice Hardcover. Oxford University Press; 2012.
Cited by
A high-performance speech neuroprosthesis
Willett, F. R., Kunz, E. M., Fan, C., Avansino, D. T., Wilson, G. H., Choi, E. Y., Kamdar, F., Glasser, M. F., Hochberg, L. R., Druckmann, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06377-x · Cited by 581
Self-citationAn Accurate and Rapidly Calibrating Speech Neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2314132 · Cited by 268
Self-citationNeuromorphic hardware for somatosensory neuroprostheses
Donati, E., & Valle, G. D. (2024) · Nature Communications · doi:10.1038/s41467-024-44723-3 · Cited by 133
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Awuah, W. A., Ahluwalia, A., Darko, K., Sanker, V., Tan, J. K., Tenkorang, P. O., Ben-Jaafar, A., Ranganathan, S., Aderinto, N., Mehta, A., et al. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.05.104 · Cited by 120
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
“83)) cortical regions on the anterior pre-central gyrus 15,16,52,98 .”
Bergeron, D., Iorio‐Morin, C., Bonizzato, M., Lajoie, G., Gaucher, N. O., Racine, É., & Weil, A. G. (2023) · Journal of Child Neurology · doi:10.1177/08830738231167736 · Cited by 61
Herring, E. Z., Graczyk, E. L., Memberg, W. D., Adams, R., Baca-Vaca, G. F., Hutchison, B. C., Krall, J. T., Alexander, B. J., Conlan, E. C., Alfaro, K. E., et al. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002769 · Cited by 49
Self-citationSonko, S., Fabuyide, A., Ibekwe, K. I., Etukudoh, E. A., & Ilojianya, V. I. (2024) · International Journal of Science and Research Archive · doi:10.30574/ijsra.2024.11.1.0111 · Cited by 42
Endovascular Brain-Computer Interfaces in Poststroke Paralysis
Brannigan, J., Fry, A., Opie, N. L., Campbell, B. C. V., Mitchell, P. J., & Oxley, T. J. (2023) · Stroke · doi:10.1161/strokeaha.123.037719 · Cited by 36
Ienca, M., Valle, G. D., & Raspopović, S. (2025) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00222-x · Cited by 34
Dohle, E., Swanson, E., Jovanović, L., Yusuf, S., Thompson, L., Horsfall, H. L., Muirhead, W. R., Bashford, L., & Brannigan, J. (2025) · Advanced Science · doi:10.1002/advs.202501912 · Cited by 31
Lo, Y. T., Lim, M. J. R., Kok, C. Y., Wang, S., Blok, S. Z., Ang, T. Y., Ng, V. Y. P., Rao, J. P., & Chua, K. S. G. (2024) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2024.04.001 · Cited by 27
Hahn, N. V., Stein, E. A., Donoghue, J. P., Simeral, J. D., Hochberg, L. R., & Willett, F. R. (2025) · medRxiv · doi:10.1101/2025.07.02.25330310 · Cited by 24
Self-citationEpidural Electrical Stimulation for Functional Recovery in Incomplete Spinal Cord Injury
Ren, Y., Mo, L., Lu, J., Zhu, P., Yin, M., Jia, W., Liang, F., Han, X., & Zhao, J. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0314 · Cited by 24
Hoeferlin, G. F., Grabinski, S. E., Druschel, L. N., Duncan, J. L., Burkhart, G., Weagraff, G. R., Lee, A. H., Hong, C., Bambroo, M., Olivares, H., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-56979-4 · Cited by 24
Self-citationSynthesizing Speech by Decoding Intracortical Neural Activity from Dorsal Motor Cortex
Wairagkar, M., Hochberg, L. R., Brandman, D. M., & Stavisky, S. D. (2023) · 2023 11th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner52421.2023.10123880 · Cited by 22
Self-citationZhang, M., Yang, Y., Zhao, Y., Sui, C., Sui, Y., Jiang, Y., Liu, K., Yang, S., Wang, L., Chen, B., et al. (2024) · Advanced technology in neuroscience . · doi:10.4103/atn.atn-d-24-00018 · Cited by 19
An accurate and rapidly calibrating speech neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2023) · doi:10.1101/2023.12.26.23300110 · Cited by 244
“…that we recorded from ventral precentral gyrus, which is upstream of the neuronal injury incurred in many conditions, and that recent ECoG speech neuroprostheses were demonstrated in two individuals with brainstem stroke 16–18 , we predict that this approach will also work in other conditions 35 .”
BackgroundSelf-citationKacker, K., Chetty, N., Feldman, A. K., Bennett, J. D., Yoo, P. E., Fry, A., Lacomis, D., Harel, N. Y., Nogueira, R. G., Majidi, S., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adbd78 · Cited by 17
Pigorini, A., Avanzini, P., Barborică, A., Bénar, C., David, O., Farisco, M., Keller, C. J., Manfridi, A., Mikulan, E., Paulk, A. C., et al. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110160 · Cited by 17
Hu, X., Li, N., Pang, M., Bai, S., Mo, J., Yao, S., Lu, Y., Huang, M., Di, J., Kang, Y., et al. (2026) · Annals of Neurology · doi:10.1002/ana.78144 · Cited by 15
The grand challenge at the frontiers of neurotechnology and its emerging clinical applications
Bhidayasiri, R. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1314477 · Cited by 14
Rubin, D. B., & Hochberg, L. R. (2023) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci57258.2023.10078547 · Cited by 13
Self-citationLee, J., Han, S. Y., & Kwon, Y. W. (2025) · Biosensors · doi:10.3390/bios15080543 · Cited by 13
King, B. J., Read, G. J. M., & Salmon, P. M. (2024) · Applied Ergonomics · doi:10.1016/j.apergo.2024.104382 · Cited by 12
Mapping the neuronal building blocks of human language with language models
Cai, J., Kfir, Y., Jamali, M., Huang, H., Kim, Y. J., Cash, S. S., & Williams, Z. M. (2026) · Nature · doi:10.1038/s41586-026-10691-5 · Cited by 11
Self-citationImplanted cortical neuroprosthetics for speech and movement restoration
Muirhead, W. R., Horsfall, H. L., Aicardi, C., Carolan, J., Akram, H., Vanhoestenberghe, A., Schaefer, A. T., & Marcus, H. J. (2024) · Journal of Neurology · doi:10.1007/s00415-024-12604-w · Cited by 10
Brain–Computer Interfaces in Spinal Cord Injury: A Promising Therapeutic Strategy
Li, S., Gao, S., Hu, Y., Xu, J., & Sheng, W. (2025) · European Journal of Neuroscience · doi:10.1111/ejn.70183 · Cited by 10
Implantable Neural Speech Decoders: Recent Advances, Future Challenges
Jhilal, S., Marchesotti, S., Thirion, B., Soudrie, B., Giraud, A., & Mandonnet, E. (2025) · Neurorehabilitation and neural repair · doi:10.1177/15459683251369468 · Cited by 9
Toward Natural Limb Function: A New Era in Prosthetic Innovation
Tian, Y., Wallace, D. M., Cederna, P. S., Chestek, C. A., & Kemp, S. W. P. (2025) · Annals of Neurology · doi:10.1002/ana.27287 · Cited by 8
Sawyer, A., Cooke, L., Breyman, E., Spohn, S., Edelman, S., Saravanan, K., & Putrino, D. F. (2024) · Neurorehabilitation and neural repair · doi:10.1177/15459683241282783 · Cited by 9
Neural–Computer Interfaces: Theory, Practice, Perspectives
Dubynin, I. A., Zemlyanskov, M. S., Shalayeva, I., Gorskii, O., Grinevich, V. P., & Евгеньевич, М. П. (2025) · Applied Sciences · doi:10.3390/app15168900 · Cited by 7
The ‘Brussels 4’: essential requirements for implantable brain–computer interface user autonomy
Oxley, T. J., Deo, D. R., Cernera, S., Sawyer, A., Putrino, D. F., Ramsey, N. F., & Fry, A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada0e6 · Cited by 7
Caregivers in implantable brain-computer interface research: a scoping review
Wohns, N., Dorfman, N. J., & Klein, E. P. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1490066 · Cited by 7
Individualized brain-computer interface for people with disabilities: a review
Saha, S., Karlsson, P., Anderson, C. J., Kavehei, O., & McEwan, A. L. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1738876 · Cited by 6
Gielas, A. (2024) · Cambridge Quarterly of Healthcare Ethics · doi:10.1017/s096318012400063x · Cited by 6
Brain-computer interface: an update for the clinicians
Jain, A., Raveendran, S., Nair, K. P. S., & Ramakrishnan, S. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1777024 · Cited by 6
Lo, Y. T., Maggi, A., Wu, K., Zhong, H., Choi, W., Nguyen, T. D., Abedi, A., Agyeman, K. A., Sakellaridi, S., Edgerton, V. R., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3570324 · Cited by 6
Neuromorphic Computing and Extended Memory
Farina, M., Ding, X., Lavazza, A., & Lai, C. (2026) · Review of Philosophy and Psychology · doi:10.1007/s13164-026-00800-8 · Cited by 5
[The research status and development trends of brain-computer interfaces in medicine].
Chen, Q., Yuan, T., Zhang, L., Gong, J., Fu, L., Han, X., Ruan, M., & Yu, Z. (2023) · PubMed Central · doi:10.7507/1001-5515.202303038 · Cited by 5
Burkhart, G., Grabinski, S. E., Wang, J., Glusauskas, G., Thompson, A., Lee, A., Zhu, Z., Donskey, C. J., von Recum, H. A., Zhang, L., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123834 · Cited by 4
Chen, Z., Huang, X., Xia, N. L., Gu, M., Xu, J., Lu, M., Chen, H., Xiong, C., & Chen, Y. (2025) · Research · doi:10.34133/research.0942 · Cited by 4
Smith, A. P., Levy, L., Hanson, C., Pouratian, N., & Feinsinger, A. (2025) · Neuroethics · doi:10.1007/s12152-025-09618-0 · Cited by 4
A roadmap to navigate the future of neural engineering
Grill, W. M., Chestek, C. A., Wang, Y., Aberra, A. S., Destexhe, A., Chan, R. H. M., Lu, B., Hanein, Y., Robinson, J. T., Whitmire, C., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae78c2 · Cited by 3
Expanding Human Capabilities with Neurotechnology: Neuroprosthetics, BCIs, and Emerging Innovations
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-78991-5_10 · Cited by 3
A Comprehensive Review of Current Assistive Technology Research for Paralyzed People
Memon, Q. A. (2024) · Studies in computational intelligence · doi:10.1007/978-3-031-61463-7_15 · Cited by 3
Magalhães, S. S., Lucas-Ochoa, A.-M., Cuello, A. M. G., Fernández‐Villalba, E., Toralles, M. B. P., & Herrero, M. T. (2025) · The Neuroscientist · doi:10.1177/10738584251318948 · Cited by 3
Restoring vision and touch with cortical microstimulation
Valle, G. D., Oswalt, D. N., Gaunt, R. A., Roelfsema, P. R., Greenspon, C. M., & Fernandez, E. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00449-z · Cited by 2
Unifying consent standards for implantable brain-computer interfaces
Young, M. J., Sandbrink, J. D., Cabrera, L. Y., Kampasi, K., Kennedy, P. F., Masood, M., Rubin, D. B., Brielmaier, L., & Ford, P. J. (2026) · Device · doi:10.1016/j.device.2026.101271 · Cited by 2
Self-citationRestoring communication with speech brain–computer interfaces
Prakash, P. R., Luo, S., Crone, N. E., & Slutzky, M. W. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24824-5.00015-6 · Cited by 2
A right-hemispheric language network at single-neuron resolutionPreprint
Schiffl, L., Held, L. M., Waitzmann, F., Eder, M., Chen, H., Alkan, G., Favero, P., Utzschmid, A., Eisenkolb, V. M., Grosse‐Wentrup, M., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.24.713937 · Cited by 2
Wagner, A., Eisenkolb, V. M., Utzschmid, A., Gempt, J., Jacob, S. N., & Meyer, B. (2026) · Operative Neurosurgery · doi:10.1227/ons.0000000000002067 · Cited by 2
Neural Interfaces: Applications, Innovative Approaches, Biocompatibility, Biomimetics
Zemlyanskov, M. S., Arsentiev, K. A., Shtol, V. S., Konovalova, S. P., Grinevich, V. P., & Евгеньевич, М. П. (2025) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093025040118 · Cited by 2
Responsible neural technology development: ethical issues and challenges
Levy, L., Wexler, A., & Feinsinger, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24824-5.00013-2 · Cited by 2
Brain–Computer Interfaces: The Dawn of a New Era in Disease Treatment
Feng, Y., Zhang, W., Chen, J., Wu, H., Wu, L., Qiu, Y., Deng, X., Zhu, C., Chen, Y., Zhao, Z., et al. (2026) · Exploration · doi:10.1002/exp.20250452 · Cited by 2
Letner, J. G., Lam, J. L. W., Copenhaver, M. G., Barrow, M., Patel, P. R., Richie, J. M., Lee, J., Kim, H.-S., Cai, D., Weiland, J. D., et al. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1848862 · Cited by 2
Neuromodulation for gait disorders
Balachandar, A., Sorrento, G. U., Moraud, E. M., Bonizzato, M., & Fasano, A. A. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00431-9 · Cited by 2
Cooperative Control of Multiple CAs
Nagai, T., Nakamura, T., Sugiura, K., Taniguchi, T., Suzuki, Y., & Hirata, M. (2024) · Springer eBooks · doi:10.1007/978-981-97-3752-9_5 · Cited by 2
Emerick, T. D., Vorenkamp, K. E., Francio, V. T., Srinivasan, S. S., Singla, P., Castellanos, J. P., Ahadian, F. M., Chen, Z., Gianlorenco, A. L., Sarno, D. L., et al. (2026) · Pain Medicine · doi:10.1093/pm/pnag076 · Cited by 2
Desideri, L., Grgič, R. G., Pirrera, A., & Giansanti, D. (2026) · Healthcare · doi:10.3390/healthcare14020274 · Cited by 2
Invasive neurointerfaces – fields of their application.
Витальевна, Б. Е., Moscow, R., Shaderkina, A. I., Efimochkina, S. M., Litavrin, A. I., & Kuznetsova, M. A. (2024) · Russian Journal of Telemedicine and E-Health · doi:10.29188/2712-9217-2024-10-2-27-42 · Cited by 2
The Ethical Concerns of Human–Computer Interface in Assistive Systems: A Systematic Survey
Ejaz, S., Ahmad, J., Shafi, I., Rehman, H. M. R. U., & Ashraf, I. (2026) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2026.2659302 · Cited by 1
Hashimoto, H., Jude, J. J., Levi-Aharoni, H., Williams, Z. M., Simeral, J. D., Hochberg, L. R., & Rubin, D. B. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.07.02.736059 · Cited by 1
Self-citationSparse neural networks enable low-power, implantable neural interfacesPreprint
Costello, J. T., Temmar, H., Cubillos, L. H., Mender, M. J., Wallace, D. M., Kelberman, M. M., Benharush, O., Simons, J., Willsey, M. S., Kumar, N. G., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.12.17.628936 · Cited by 1
Invasive Brain–Computer Interfaces: 25 Years of Clinical Trials, Scientific and Practical Issues
Mokienko, O. A. (2025) · Annals of the Russian academy of medical sciences · doi:10.15690/vramn17994 · Cited by 1
Rethink the motor cortical control via the experiment-analysis-model flywheel: an overview
Jiang, H., Bu, X., Shi, Q., Zheng, Z., Zhu, D., Tang, H., & Chen, Y. (2025) · Med-X · doi:10.1007/s44258-025-00059-1 · Cited by 1
Higham, S. J., Jung, Y. J., León, S. E. D., Tong, W., Au, S. L. C., Shang, Y., Wang, H., Kalra, M., Morokoff, A. P., Maturana, M. I., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.06.696090 · Cited by 1
From Humans to Humans: Designing Human-Centered AI for Better Healthcare
Wu, Y. (2025) · Advances in computational intelligence and robotics book series · doi:10.4018/979-8-3693-5837-5.ch006 · Cited by 1
BCI-sift: An automated feature selection toolbox for Brain Computer Interface applicationsPreprint
Offenberg, E. C., Keller, D., Vansteensel, M. J., Freudenburg, Z. V., Ramsey, N. F., & Berezutskaya, J. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2605.19646 · Cited by 1
Two Studies Find Few Brain-Computer Interface-related Adverse Events
Hurley, D. (2023) · Neurology Today · doi:10.1097/01.nt.0000921180.36938.e7 · Cited by 1
Neural Digital Twins: Toward Next-Generation Brain-Computer InterfacesPreprint
Bina, M. M. H., Baghernezhad, S., Daliri, M. R., & Moradi, M. H. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2601.01539 · Cited by 1
Internet Security Issues in Robotics for Brain-Computer Interface: Opportunities and Challenges
Ghosh, A., Poria, S., & Saha, S. (2025) · Information systems engineering and management · doi:10.1007/978-3-031-96871-6_13
Khaboushan, A. S., Ajagbe͓, A. O., Chiemena, A. P., Rabiee, K., Rahimzadegan, M., Hassannejad, Z., Bharmauria, V., & Flouty, O. (2026) · Interdisciplinary Neurosurgery · doi:10.1016/j.inat.2026.102197
Great Leaps Forward in Brain-Computer Interfaces for ALS Communication
Shaw, G. (2024) · Neurology Today · doi:10.1097/01.nt.0001081264.79652.58
Huggins, J. E., Mattia, D., Aarnoutse, E. J., Allison, B. Z., Berezutskaya, J., Bianchi, L., Chavarriaga, R., Corsi, M., Dean, H., Fernandes, F., et al. (2026) · Research in Biomedical Engineering and Technology · doi:10.1080/29960355.2026.2731643
Brain-Spine Interface Restores Standing, Walking, and Stair-Climbing After Spinal Cord Injury
Hurley, D. (2023) · Neurology Today · doi:10.1097/01.nt.0000946564.14834.d4
Yao, R., Zhou, W., Liu, D., Li, W., Liang, F., Liu, T., Xu, H., Wang, J., & Hong, B. (2025) · medRxiv · doi:10.1101/2025.10.06.25337264
Jha, N. K., Liu, C. P., Rogers, A. C., & Lozano, A. (2026) · Mayo Clinic Proceedings Digital Health · doi:10.1016/j.mcpdig.2026.100366
Tao, S., Feng, L., Jia, S., Xu, B., & Yu, S. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae9595
Hereth, B., de Boisboissel, G., Bricknell, M. C. M., Brincker, M., Casebeer, W. D., Davidovic, J., Davis, J., Earl, J., Eisikovits, N., Feldman, D., et al. (2025) · Science and Engineering Ethics · doi:10.1007/s11948-025-00546-z
Song, Y., Guo, H., Yu, Z., Wang, A., Li, J., Pei, Z., Chen, J., Zhang, X., Guo, H., Wu, X., et al. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1953098
Piterak, P., Danilczuk, D., Buszko, J., Dyś, M., Baran, N., Bajkowska-Piterak, M., Szlachta-Gubernat, M., Adamiec, W., & Buż, A. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.3(51).2026.5813
Xing, B., Zhang, L., & Tu, W.-J. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1994636
Modulation: Fine Tuning and Resetting of Neurological Function
Gelman, K., Ranjan, M., Konrad, P. E., & Rezai, A. R. (2025) · Cambridge University Press eBooks · doi:10.1017/9781009597852.007
A sociotechnical systems’ perspective to support brain–computer interface development
King, B. J., Read, G. J. M., & Salmon, P. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95439-6.00006-5
Influence of Electrical Double Layer and Amplifier Impedance on Intracortical Neural Signals
Saikia, P., Sridhar, K., Kennedy, P., Andreasen, D. S., O'Hare, D., & Lowery, M. M. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11589095
Araújo, M. S., Rodrigues, L. C., da Silva, C. O. B., Oliveira, A. D. A., Lima, A. M. G., Silva, L. D. S., Carvalho, R. K. D. S., de Oliveira, S. S., Melo, A. R. D. S., de Oliveira, G. A. L., et al. (2026) · Editora Inovar eBooks · doi:10.36926/editorainovar-978-65-5388-394-9_024
Foulkes, A. L., Versalovic, E., Merner, A. R., & Lázaro‐Muñoz, G. (2026) · bepress Legal Repository
Brain Implants in the Age of Artificial Intelligence.
Kundu, B., & Pleitez, J. (2025) · PubMed Central
Lu, X., Xiao, X., Wu, Y., Wei, Y., & Li, B. (2025) · Current Neuropharmacology · doi:10.2174/011570159x443258251114091930
Aivokäyttöliittymien historia, nykytila ja tulevaisuus
Jaakkola, N. (2026) · Tampere University Institutional Repository (Tampere University)
Decoding attempted handwritten characters based on temporal endovascular neural features
Kokorin, K., Mu, J., Grayden, D. B., John, S. E., & Yoo, P. E. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/aeb82b
Optimizing Future Advanced BCIs: Using WDA to Identify Potential Pain Points in BCI Systems
King, B. J., Read, G. J. M., & Salmon, P. M. (2023) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/21695067231192882
AI-Guided Neuroengineering for Spinal Circuit Reconstruction and Functional IntegrationPreprint
Kumar, R. K., Sporn, K., Ravi, P., Vaja, S., Zaman, N., & Tavakkoli, A. (2025) · Preprints.org · doi:10.20944/preprints202506.1956.v1
Neuroimplanttien kyberturvallisuus
Kainulainen, A. (2024) · Tampere University Institutional Repository (Tampere University)
Stroke and spasticity: a comprehensive approach from the acute phase to rehabilitation
Musuruana, A., & Revelant, M. R. (2024) · International Journal of Neurology · doi:10.62486/ijn2024137
Metadata
- Authors
- Rubin, D. B., Ajiboye, A. B., Barefoot, L., Bowker, M., Cash, S. S., Chen, D., Donoghue, J. P., Eskandar, E. N., Friehs, G., Grant, C., Henderson, J. M., Kirsch, R. F., Marujo, R., Masood, M., Mernoff, S. T., Miller, J. P., Mukand, J. A., Penn, R. D., Shefner, J., Shenoy, K. V., Simeral, J. D., Sweet, J. A., Walter, B. L., Williams, Z. M., & Hochberg, L. R.
- Affiliations
- Harvard University (US)
- Shirley Ryan AbilityLab (US)
- Albert Einstein College of Medicine (US)
- Barrow Neurological Institute (US)
- Cleveland Clinic (US)
- Corresponding author
- Rubin, Daniel B.
- ORCID
- Venue
- Neurology
- Published
- 2023-03-14
- Volume
- 100
- Issue
- 11
- Pages
- e1177-e1192
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- PMC
- PMC10074470
- OpenAlex
- W4316020459
- Semantic Scholar
- 2a253efd0a6174fb40de0a8c48f21fc464f9e7b0
- Cited by
- 81
- References
- 48
- Citations by year
- 2026: 24 · 2025: 25 · 2024: 24 · 2023: 8
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Neurology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Howard Hughes Medical Institute
- U.S. Department of Veterans Affairs (IK6 RX004284, I01 RX002295, I50RX002864, B6453-R, N9228C, B6459L, N-2864-C)
- American Heart Association (19CSLOI34780000)
- Massachusetts General Hospital
- Brown University
- Harvard Catalyst
- Case Western Reserve University
- National Institutes of Health (n01hd53403-6-0-1, N01HD10018, 5uh2ns095548-02, 5u01dc017844-06)
- U.S. Food and Drug Administration
- Wu Tsai Neurosciences Institute, Stanford University
- Office of Naval Research (N00014)
- National Institute on Deafness and Other Communication Disorders (R01DC009899, R01DC014034, U01- DC017844)
- National Institute of Neurological Disorders and Stroke (R01NS062092, UH2-NS095548, U01NS098968, UE5NS065743, R25NS065743)
- National Institute of Biomedical Imaging and Bioengineering (T32EB004314)
- National Institute of Child Health and Human Development
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (N01-HD-53403, R01HD077220, N01HD10018)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- brain-computer interface, chronic implantation, microelectrode arrays, motor cortex, device-related adverse events, device explantation, tetraparesis, spinal cord injury, brainstem infarction, motor neuron disease, assistive technology, risk-benefit assessment
- MeSH terms
- Adult, Feasibility Studies, Humans, Prospective Studies, Quadriplegia, Spinal Cord Injuries, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.