The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
“Other promising microelectrodes include microwires and micromachined microelectrode arrays [30], [33]–[35], [39], [40].”
BackgroundNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“Another set of experiments revealed that adhesions had formed between a UEA implant and the dural tissue above the brain, possibly due to a robust foreign body response mediated by micromotion of the implant relative to the dura (Rousche and Normann, 1998).”
BackgroundMethodResultInfluentialBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. https://app.cochat.ai/papers/10.1016/s0165-0270(98)00031-4
- The paper
- Rousche, P. J., & Normann, R. A. (1998). Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. Journal of Neuroscience Methods. https://doi.org/10.1016/s0165-0270(98)00031-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.