Interim Safety Profile From the Feasibility Study of the BrainGate Neural Interface System
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVES: Brain-computer interfaces (BCIs) are being developed to restore mobility, communication, and functional independence to people with paralysis. Though supported by decades of preclinical data, the safety of chronically implanted microelectrode array BCIs in humans is unknown. We report safety results from the prospective, open-label, nonrandomized BrainGate feasibility study (NCT00912041), the largest and longest-running clinical trial of an implanted BCI. METHODS: Adults aged 18-75 years with quadriparesis from spinal cord injury, brainstem stroke, or motor neuron disease were enrolled through 7 clinical sites in the United States. Participants underwent surgical implantation of 1 or 2 microelectrode arrays in the motor cortex of the dominant cerebral hemisphere. The primary safety outcome was device-related serious adverse events (SAEs) requiring device explantation or resulting in death or permanently increased disability during the 1-year postimplant evaluation period. The secondary outcomes included the type and frequency of other adverse events and the feasibility of the BrainGate system for controlling a computer or other assistive technologies. RESULTS: From 2004 to 2021, 14 adults enrolled in the BrainGate trial had devices surgically implanted. The average duration of device implantation was 872 days, yielding 12,203 days of safety experience. There were 68 device-related adverse events, including 6 device-related SAEs. The most common device-related adverse event was skin irritation around the percutaneous pedestal. There were no safety events that required device explantation, no unanticipated adverse device events, no intracranial infections, and no participant deaths or adverse events resulting in permanently increased disability related to the investigational device. DISCUSSION: The BrainGate Neural Interface system has a safety record comparable with other chronically implanted medical devices. Given rapid recent advances in this technology and continued performance gains, these data suggest a favorable risk/benefit ratio in appropriately selected individuals to support ongoing research and development. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov Identifier: NCT00912041. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that the neurosurgically placed BrainGate Neural Interface system is associated with a low rate of SAEs defined as those requiring device explantation, resulting in death, or resulting in permanently increased disability during the 1-year postimplant period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Intracortical MEA recordings are used to measure neural activity at the level of single neurons or neuron clusters83.”
From The speech neuroprosthesis (2024) · cites this paper as [83]
The cited source says what the claim attributes to it.
In the citing paper
“although recent safety data are encouraging34”
From A high-performance speech neuroprosthesis (2023) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“(7) Brain machine interfaces incorporating neural population dynamics.”
BackgroundSelf-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
Self-citationBacterial Meningitis in the United States, 1998–2007
Thigpen, M. C., Whitney, C. G., Messonnier, N. E., Zell, E. R., Lynfield, R., Hadler, J. L., Harrison, L. H., Farley, M. M., Reingold, A., Bennett, N. M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1005384 · Cited by 953
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Self-citationNeuroprosthesis for Decoding Speech in a Paralyzed Person with Anarthria
Moses, D. A., Metzger, S. L., Liu, J. R., Anumanchipalli, G. K., Makin, J. G., Sun, P. F., Chartier, J., Dougherty, M. E., Liu, P. M., Abrams, G. M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2027540 · Cited by 582
Fully Implanted Brain–Computer Interface in a Locked-In Patient with ALS
Vansteensel, M. J., Pels, E. G. M., Bleichner, M. G., Branco, M. P., Denison, T., Freudenburg, Z. V., Gosselaar, P., Leinders, S., Ottens, T. H., Van Den Boom, M. A., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1608085 · Cited by 578
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
Self-citationClosed-loop neuromodulation in an individual with treatment-resistant depression
Scangos, K. W., Khambhati, A. N., Daly, P. M., Makhoul, G. S., Sugrue, L. P., Zamanian, H., Liu, T. X., Rao, V. R., Sellers, K. K., Dawes, H. E., et al. (2021) · Nature Medicine · doi:10.1038/s41591-021-01480-w · Cited by 535
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Self-citationNine-year prospective efficacy and safety of brain-responsive neurostimulation for focal epilepsy
Nair, D. R., Laxer, K. D., Weber, P. B., Murro, A. M., Park, Y. D., Barkley, G. L., Smith, B. J., Gwinn, R. P., Doherty, M. J., Noe, K. H., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000010154 · Cited by 490
Self-citationSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Self-citationDeep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Surgical and hardware complications of subthalamic stimulation: A series of 160 procedures
Lyons, K. E., Wilkinson, S. B., Overman, J., & Pahwa, R. (2004) · Neurology · doi:10.1212/01.wnl.0000134650.91974.1a · Cited by 271
Oxley, T. J., Yoo, P. E., Rind, G. S., Ronayne, S. M., Lee, C. M. S., Bird, C., Hampshire, V., Sharma, R. P., Morokoff, A., Williams, D. L., et al. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-016862 · Cited by 243
Self-citationHow do People Type on Mobile Devices?: Observations from a Study with 37,000 Volunteers
Palin, K., Feit, A. M., Kim, S., Kristensson, P. O., & Oulasvirta, A. (2019) · Proceedings of the 21st International Conference on Human-Computer Interaction with Mobile Devices and Services · doi:10.1145/3338286.3340120 · Cited by 190
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165 · cited 1×
“(10) Multiplicative recurrent neural network for fast and robust intracortical brain-machine interface decoders.”
BackgroundSelf-citationRapid calibration of an intracortical brain–computer interface for people with tetraplegia
Brandman, D. M., Hosman, T., Saab, J., Burkhart, M. C., Shanahan, B. E., Ciancibello, J. G., Sarma, A. A., Milstein, D. J., Vargas-Irwin, C. E., Franco, B., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee7 · Cited by 153
Self-citationSeijo, F., Vega, M. A. Á., Morales, J. C. G., Fdez-Glez, F., & Lozano, B. R. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-007-1267-1 · Cited by 151
Chaudhary, U., Vlachos, I., Zimmermann, J. B., Espinosa, A., Tonin, A., Jaramillo-Gonzalez, A., Khalili-Ardali, M., Topka, H., Lehmberg, J., Friehs, G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28859-8 · Cited by 139
Self-citationEye typing in application: A comparison of two systems with ALS patients
Pannasch, S., Helmert, J. R., Malischke, S., Storch, A., & Velichkovsky, B. M. (2008) · Journal of Eye Movement Research · doi:10.16910/jemr.2.4.6 · Cited by 137
Sensor Modalities for Brain-Computer Interface Technology: A Comprehensive Literature Review
Martini, M. L., Oermann, E. K., Opie, N. L., Panov, F. E., Oxley, T. J., & Yaeger, K. (2019) · Neurosurgery · doi:10.1093/neuros/nyz286 · Cited by 136
Neural Point-and-Click Communication by a Person With Incomplete Locked-In Syndrome
Bacher, D., Jarosiewicz, B., Masse, N. Y., Stavisky, S. D., Simeral, J. D., Newell, K., Oakley, E. M., Cash, S. S., Friehs, G., & Hochberg, L. R. (2015) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968314554624 · Cited by 124
Self-citationSon, B.-C., Shon, Y. M., Choi, J.-G., Kim, J., Ha, S.-W., Kim, S., & Lee, S. (2016) · Stereotactic and Functional Neurosurgery · doi:10.1159/000446611 · Cited by 124
Cryptogenic New Onset Refractory Status Epilepticus (NORSE) in adults—Infectious or not?
Costello, D. J., Kilbride, R. D., & Cole, A. J. (2008) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2008.10.007 · Cited by 121
Long-Term Surgical and Hardware-Related Complications of Deep Brain Stimulation
Doshi, P. K. (2011) · Stereotactic and Functional Neurosurgery · doi:10.1159/000323372 · Cited by 113
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
Self-citationDegenhart, A. D., Eles, J., Dum, R., Mischel, J. L., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler-Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 94
Lee, B., Zubair, M. N., Marquez, Y. D., Lee, D. M., Kalayjian, L. A., Heck, C. N., & Liu, C. Y. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2015.04.050 · Cited by 91
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
Vergani, F., Landi, A., Pirillo, D., Cilia, R., Antonini, A., & Sganzerla, E. P. (2010) · World Neurosurgery · doi:10.1016/j.wneu.2010.01.017 · Cited by 88
Linse, K., Aust, E., Joos, M., & Hermann, A. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00603 · Cited by 84
Colachis, S. C., Bockbrader, M. A., Zhang, M., Friedenberg, D. A., Annetta, N. V., Schwemmer, M. A., Skomrock, N. D., Mysiw, W. J., Rezai, A. R., Bresler, H. S., et al. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00208 · Cited by 67
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Cajigas, I., Davis, K. C., Meschede-Krasa, B., Prins, N. W., Gallo, S., Naeem, J. A., Palermo, A., Wilson, A., Guerra, S., Parks, B. A., et al. (2021) · Brain Communications · doi:10.1093/braincomms/fcab248 · Cited by 60
Lu, G., Luo, L., Liu, M., Zheng, Z., Zhang, B., Chen, X., Hua, X., Fan, H., Mo, G., Duan, J., et al. (2020) · Neural Plasticity · doi:10.1155/2020/2486065 · Cited by 56
Lee, B., Liu, C. Y., & Apuzzo, M. L. J. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.01.078 · Cited by 48
Soldozy, S., Young, S., Kumar, J. S., Capek, S., Felbaum, D. R., Jean, W. C., Park, M. S., & Syed, H. R. (2020) · Neurosurgical FOCUS · doi:10.3171/2020.4.focus20186 · Cited by 34
Hochberg, L. R., & Cudkowicz, M. E. (2014) · Neurology · doi:10.1212/wnl.0000000000000460 · Cited by 23
Self-citationShort report: surgery for implantable brain-computer interface assisted by robotic navigation system
Jiang, H., Wang, R., Zheng, Z., Zhu, J., Qi, Y., Xu, K., & Zhang, J. (2022) · Acta Neurochirurgica · doi:10.1007/s00701-022-05235-5 · Cited by 18
The ERICA eye gaze system versus manual letter board to aid communication in ALS/MND
Harris, D., & Goren, M. (2009) · British Journal of Neuroscience Nursing · doi:10.12968/bjnn.2009.5.5.42128 · Cited by 13
Wiring up the brain to beat depression
Drew, L. (2022) · Nature · doi:10.1038/d41586-022-02209-6 · Cited by 2
Research works printed but not linked: 1
- Hochberg LR, Anderson K. BCI users and their needs. In: Wolpaw JR, Wolpaw E, eds. Brain-Computer Interfaces: Principles and Practice Hardcover. Oxford University Press; 2012.
Cited by
A high-performance speech neuroprosthesis
Willett, F. R., Kunz, E. M., Fan, C., Avansino, D. T., Wilson, G. H., Choi, E. Y., Kamdar, F., Glasser, M. F., Hochberg, L. R., Druckmann, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06377-x · Cited by 581
Self-citationAn Accurate and Rapidly Calibrating Speech Neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2314132 · Cited by 268
Self-citationNeuromorphic hardware for somatosensory neuroprostheses
Donati, E., & Valle, G. D. (2024) · Nature Communications · doi:10.1038/s41467-024-44723-3 · Cited by 133
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Awuah, W. A., Ahluwalia, A., Darko, K., Sanker, V., Tan, J. K., Tenkorang, P. O., Ben-Jaafar, A., Ranganathan, S., Aderinto, N., Mehta, A., et al. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.05.104 · Cited by 120
Metadata
- Authors
- Rubin, D. B., Ajiboye, A. B., Barefoot, L., Bowker, M., Cash, S. S., Chen, D., Donoghue, J. P., Eskandar, E. N., Friehs, G., Grant, C., Henderson, J. M., Kirsch, R. F., Marujo, R., Masood, M., Mernoff, S. T., Miller, J. P., Mukand, J. A., Penn, R. D., Shefner, J., Shenoy, K. V., Simeral, J. D., Sweet, J. A., Walter, B. L., Williams, Z. M., & Hochberg, L. R.
- Affiliations
- Harvard University (US)
- Shirley Ryan AbilityLab (US)
- Albert Einstein College of Medicine (US)
- Barrow Neurological Institute (US)
- Cleveland Clinic (US)
- Corresponding author
- Rubin, Daniel B.
- ORCID
- Venue
- Neurology
- Published
- 2023-03-14
- Volume
- 100
- Issue
- 11
- Pages
- e1177-e1192
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- PMC
- PMC10074470
- OpenAlex
- W4316020459
- Semantic Scholar
- 2a253efd0a6174fb40de0a8c48f21fc464f9e7b0
- Cited by
- 81
- References
- 48
- Citations by year
- 2026: 24 · 2025: 25 · 2024: 24 · 2023: 8
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Neurology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Howard Hughes Medical Institute
- U.S. Department of Veterans Affairs (IK6 RX004284, I01 RX002295, I50RX002864, B6453-R, N9228C, B6459L, N-2864-C)
- American Heart Association (19CSLOI34780000)
- Massachusetts General Hospital
- Brown University
- Harvard Catalyst
- Case Western Reserve University
- National Institutes of Health (n01hd53403-6-0-1, N01HD10018, 5uh2ns095548-02, 5u01dc017844-06)
- U.S. Food and Drug Administration
- Wu Tsai Neurosciences Institute, Stanford University
- Office of Naval Research (N00014)
- National Institute on Deafness and Other Communication Disorders (R01DC009899, R01DC014034, U01- DC017844)
- National Institute of Neurological Disorders and Stroke (R01NS062092, UH2-NS095548, U01NS098968, UE5NS065743, R25NS065743)
- National Institute of Biomedical Imaging and Bioengineering (T32EB004314)
- National Institute of Child Health and Human Development
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (N01-HD-53403, R01HD077220, N01HD10018)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- brain-computer interface, chronic implantation, microelectrode arrays, motor cortex, device-related adverse events, device explantation, tetraparesis, spinal cord injury, brainstem infarction, motor neuron disease, assistive technology, risk-benefit assessment
- MeSH terms
- Adult, Feasibility Studies, Humans, Prospective Studies, Quadriplegia, Spinal Cord Injuries, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.