CoChat

Octanoic acid in alcohol-responsive essential tremor: A randomized controlled study

Open access
Haubenberger, Dietrich, McCrossin, Gayle, Lungu, Codrin, Considine, Elaine, Toro, Camilo, Nahab, Fatta B., Auh, Sungyoung, Buchwald, Peter, Grimes, George J., Starling, Judith, Potti, Gopal, Scheider, Linda, Kalowitz, Daniel, Bowen, Daniel, Carnie, Andrea, Hallett, Mark · 2013 · Neurology
Cited by 40

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess safety and efficacy of an oral, single, low dose of octanoic acid (OA) in subjects with alcohol-responsive essential tremor (ET). METHODS: We conducted a double-blind, placebo-controlled, crossover, phase I/II clinical trial evaluating the effect of 4 mg/kg OA in 19 subjects with ET. The primary outcome was accelerometric postural tremor power of the dominant hand 80 minutes after administration. Secondary outcomes included digital spiral analysis, pharmacokinetic sampling, as well as safety measures. RESULTS: OA was safe and well tolerated. Nonserious adverse events were mild (Common Terminology Criteria for Adverse Events grade 1) and equally present after OA and placebo. At the primary outcome, OA effects were not different from placebo. Secondary outcome analyses of digital spiral analysis, comparison across the entire time course in weighted and nonweighted accelerometry, as well as nondominant hand tremor power did not show a benefit of OA over placebo. The analysis of individual time points showed that OA improved tremor at 300 minutes (dominant hand, F = 5.49, p = 0.032 vs placebo), with a maximum benefit at 180 minutes after OA (both hands, F = 6.1, p = 0.025). CONCLUSIONS: Although the effects of OA and placebo at the primary outcome were not different, secondary outcome measures suggest superiority of OA in reducing tremor at later time points, warranting further trials at higher dose levels. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that a single 4-mg/kg dose of OA is not effective in reducing postural tremor in patients with ET at a primary outcome of 80 minutes, but is effective for a secondary outcome after 180 minutes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0b013e3182840c4f

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 40

Metadata

Authors
Haubenberger, D., McCrossin, G., Lungu, C., Considine, E., Toro, C., Nahab, F. B., Auh, S., Buchwald, P., Grimes, G. J., Starling, J., Potti, G., Scheider, L., Kalowitz, D., Bowen, D., Carnie, A., & Hallett, M.
Venue
Neurology
Published
2013-03-05
Volume
80
Issue
10
Pages
933-940
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2139669907
Cited by
40
References
4
FWCI
2.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Octanoic acid in alcohol-responsive essential tremor: A randomized controlled study. https://app.cochat.ai/papers/10.1212/wnl.0b013e3182840c4f
The paper
Haubenberger, D., McCrossin, G., Lungu, C., Considine, E., Toro, C., Nahab, F. B., Auh, S., Buchwald, P., Grimes, G. J., Starling, J., Potti, G., Scheider, L., Kalowitz, D., Bowen, D., Carnie, A., & Hallett, M. (2013). Octanoic acid in alcohol-responsive essential tremor: A randomized controlled study. Neurology. https://doi.org/10.1212/wnl.0b013e3182840c4f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.