The DOI matches its Crossref record.
Combined depth and subdural electrode investigation in uncontrolled epilepsy
Abstract
We used both depth and subdural electrodes to obtain localization of the seizure focus in 47 medically refractory epileptic patients. Seizures were localized in 33 patients. Onset was consistently localized by the depth electrodes in 23 patients, was variable or simultaneous in depth and subdural electrodes in 6 (in the same lobe), and was consistently localized to subdural electrodes in 4. All patients localized with subdural electrodes were extratemporal and 3 of the 4 had lesions on imaging studies which helped guide location of electrode placement. Eighty-seven percent of temporal lobe seizures began in hippocampus (recorded by the depth electrode), and 80% were eventually propagated to the ipsilateral temporal neocortex (recorded by the subdural electrode). In 8 patients with bilateral temporal depth and subdural recording, seizures never spread to the contralateral neocortex before the ipsilateral neocortex. Subdural electrodes were 20% less sensitive than depth electrodes in detection of seizures beginning in hippocampus but were accurate when lateralized. Variable or simultaneous unilateral neocortical versus hippocampal temporal lobe seizure onset, determined by the combined study, was significantly correlated with less favorable seizure control after anteromedial temporal lobectomy and hippocampectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sloviter, R. S. (1994) · Annals of Neurology · doi:10.1002/ana.410350604 · Cited by 454
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Complications of invasive video-EEG monitoring with subdural grid electrodes
Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., et al. (2002) · Neurology · doi:10.1212/wnl.58.1.97 · Cited by 289
Semiologic and Electrophysiologic Correlations in Temporal Lobe Seizure Subtypes
Maillard, L., Vignal, J., Gavaret, M., Guye, M., Biraben, A., McGonigal, A., Chauvel, P., & Bartolomei, F. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.09704.x · Cited by 279
Neural networks involving the medial temporal structures in temporal lobe epilepsy
Bartolomei, F., Wendling, F., Bellanger, J.-J., Régis, J., & Chauvel, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00591-0 · Cited by 276
Metadata
- Authors
- Spencer, S. S., Spencer, D. D., Williamson, P. D., & Mattson, R.
- Venue
- Neurology
- Published
- 1990-01
- Volume
- 40
- Issue
- 1
- Pages
- 74-74
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2040810270
- Cited by
- 251
- References
- 0
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined depth and subdural electrode investigation in uncontrolled epilepsy. https://app.cochat.ai/papers/10.1212/wnl.40.1.74
- The paper
- Spencer, S. S., Spencer, D. D., Williamson, P. D., & Mattson, R. (1990). Combined depth and subdural electrode investigation in uncontrolled epilepsy. Neurology. https://doi.org/10.1212/wnl.40.1.74
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.