The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Complications of invasive video-EEG monitoring with subdural grid electrodes
Abstract
OBJECTIVE: To evaluate the risk factors, type, and frequency of complications during video-EEG monitoring with subdural grid electrodes. METHODS: The authors retrospectively reviewed the records of all patients who underwent invasive monitoring with subdural grid electrodes (n = 198 monitoring sessions on 187 patients; median age: 24 years; range: 1 to 50 years) at the Cleveland Clinic Foundation from 1980 to 1997. RESULTS: From 1980 to 1997, the complication rate decreased (p = 0.003). In the last 5 years, 19/99 patients (19%) had complications, including two patients (2%) with permanent sequelae. In the last 3 years, the complication rate was 13.5% (n = 5/37) without permanent deficits. Overall, complications occurred during 52 monitoring sessions (26.3%): infection (n = 24; 12.1%), transient neurologic deficit (n = 22; 11.1%), epidural hematoma (n = 5; 2.5%), increased intracranial pressure (n = 5; 2.5%), and infarction (n = 3; 1.5%). One patient (0.5%) died during grid insertion. Complication occurrence was associated with greater number of grids/electrodes (p = 0.021/p = 0.052; especially >60 electrodes), longer duration of monitoring (p = 0.004; especially >10 days), older age of the patient (p = 0.005), left-sided grid insertion (p = 0.01), and burr holes in addition to the craniotomy (p = 0.022). No association with complications was found for number of seizures, IQ, anticonvulsants, or grid localization. CONCLUSIONS: Invasive monitoring with grid electrodes was associated with significant complications. Most of them were transient. Increased complication rates were related to left-sided grid insertion and longer monitoring with a greater number of electrodes (especially more than 60 electrodes). Improvements in grid technology, surgical technique, and postoperative care resulted in significant reductions in the complication rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical and Neurological Complications in a Series of 708 Epilepsy Surgery Procedures
Behrens, E., Schramm, J., Zentner, J., & König, R. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00004 · Cited by 294
Combined depth and subdural electrode investigation in uncontrolled epilepsy
Spencer, S. S., Spencer, D. D., Williamson, P. D., & Mattson, R. (1990) · Neurology · doi:10.1212/wnl.40.1.74 · Cited by 251
Subdural and depth electrodes in the presurgical evaluation of epilepsy
Behrens, E., Zentner, J., van Roost, D., Hufnagel, A., Elger, C. E., & Schramm, J. (1994) · Acta Neurochirurgica · doi:10.1007/bf01400656 · Cited by 161
Use of Subdural Grids and Strip Electrodes to Identify a Seizure Focus in Children
Adelson, D., Black, P. M., Madsen, J. R., et al. (2008) · Pediatric Neurosurgery · doi:10.1159/000120898 · Cited by 97
The morbidity of long-term seizure monitoring using subdural strip electrodes
Wyler, A. R., Walker, G. R., & Somes, G. W. (1991) · Journal of neurosurgery · doi:10.3171/jns.1991.74.5.0734 · Cited by 96
Wiggins, G. C., Elisevich, K. V., & Smith, B. J. (1999) · Epilepsy Research · doi:10.1016/s0920-1211(99)00037-6 · Cited by 87
Fernández, G., Hufnagel, A., Roost, D. V., Helmstaedter, C., Wolf, H. K., Zentner, J., Schramm, J., & Elger, C. E. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01258.x · Cited by 55
Cited by
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Clinical applications of the functional connectome
Castellanos, F. X., Di Martino, A., Craddock, R. C., Mehta, A. D., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.083 · Cited by 312
Stereoelectroencephalography in presurgical assessment of MRI-negative epilepsy
McGonigal, A., Bartolomei, F., Regis, J., Guye, M., Gavaret, M., Fonseca, A. T.-D., Dufour, H., Figarella-Branger, D., Girard, N., Peragut, J.-C., et al. (2007) · Brain · doi:10.1093/brain/awm218 · Cited by 290
Metadata
- Authors
- Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., Kotagal, P., Najm, I., Wyllie, E., & Lüders, H. O.
- Venue
- Neurology
- Published
- 2002-01-08
- Volume
- 58
- Issue
- 1
- Pages
- 97-103
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2088103763
- Cited by
- 289
- References
- 7
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications of invasive video-EEG monitoring with subdural grid electrodes. https://app.cochat.ai/papers/10.1212/wnl.58.1.97
- The paper
- Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., Kotagal, P., Najm, I., Wyllie, E., & Lüders, H. O. (2002). Complications of invasive video-EEG monitoring with subdural grid electrodes. Neurology. https://doi.org/10.1212/wnl.58.1.97
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.