Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We studied whether a triple dose of gadolinium-DTPA alone or in combination with delayed scanning increases the sensitivity of brain MRI for detecting enhancing lesions in patients with MS. We obtained T1-weighted brain MRI scans in two sessions for 22 patients with clinically definite MS. In the first session, we obtained one scan 5 to 7 minutes after the injection of 0.1 mmol/kg gadolinium-DTPA (standard dose). In the second session, 6 to 24 hours later, we obtained one scan before the two scans 5 to 7 minutes (for all patients) and one hour (for 11 patients) after the injection of 0.3 mmol/kg gadolinium-DTPA (triple dose). We detected 83 enhancing lesions in 14 patients when the standard dose of gadolinium-DTPA was used. The numbers of enhancing lesions increased to 138 (average increase 66%; p = 0.001) and the numbers of patients with such lesions to 18 (increase 28%) when we used the triple dose of gadolinium-DTPA. In addition, the total area per patient occupied by such lesions was greater (p < 0.0001) and lesion signal intensity higher (p = 0.0001) on the triple-dose scans than the standard-dose scans. There was an increase in the number of large enhancing lesions (p = 0.03) in the scans obtained 1 hour after the injection of the triple dose of gadolinium-DTPA. These data indicate that in patients with MS, a triple dose of gadolinium-DTPA can reveal many more enhancing lesions, which also appear larger. This suggests that the pathologic nature of "active" lesions in MS is heterogeneous, which might have impact on planning clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Katz, D., Taubenberger, J. K., Cannella, B., McFarlin, D. E., Raine, C. S., & McFarland, H. F. (1993) · Annals of Neurology · doi:10.1002/ana.410340507 · Cited by 387
HAWKINS, C. P., MUNRO, P. M. G., MACKENZIE, F., KESSELRING, J., TOFTS, P. S., BOULAY, E. P. G. H. D., LANDON, D. N., & McDONALD, W. I. (1990) · Brain · doi:10.1093/brain/113.2.365 · Cited by 219
Cited by
The role of magnetic resonance techniques in understanding and managing multiple sclerosis
Miller, D. (1998) · Brain · doi:10.1093/brain/121.1.3 · Cited by 556
Filippi, M., Rocca, M. A., Martino, G., Horsfield, M. A., & Comi, G. (1998) · Annals of Neurology · doi:10.1002/ana.410430616 · Cited by 395
Self-citationWerring, D. J. (2000) · Brain · doi:10.1093/brain/123.8.1667 · Cited by 326
Schimrigk, S., Brune, N., Hellwig, K., Lukas, C., Bellenberg, B., Rieks, M., Hoffmann, V., Pöhlau, D., & Przuntek, H. (2006) · European Journal of Neurology · doi:10.1111/j.1468-1331.2006.01292.x · Cited by 217
“3 mmol/kg body weight) Gd-diethylenetriamine pentaacetic acid (Gd-DPTA, Magnevist , Schering AG, Berlin, Germany) was administered for higher lesion detection sensitivity [23].”
MethodCadavid, D., Wolansky, L. J., Skurnick, J., Lincoln, J., Cheriyan, J., Szczepanowski, K., Kamin, S. S., Pachner, A. R., Halper, J., & Cook, S. D. (2009) · Neurology · doi:10.1212/01.wnl.0000345970.73354.17 · Cited by 185
Metadata
- Authors
- Filippi, M., Yousry, T., Campi, A., Kandziora, C., Colombo, B., Voltz, R., Martinelli, V., Spuler, S., Bressi, S., Scotti, G., & Comi, G.
- Venue
- Neurology
- Published
- 1996-02
- Volume
- 46
- Issue
- 2
- Pages
- 379-384
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2045430930
- Cited by
- 124
- References
- 2
- FWCI
- 10.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS. https://app.cochat.ai/papers/10.1212/wnl.46.2.379
- The paper
- Filippi, M., Yousry, T., Campi, A., Kandziora, C., Colombo, B., Voltz, R., Martinelli, V., Spuler, S., Bressi, S., Scotti, G., & Comi, G. (1996). Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS. Neurology. https://doi.org/10.1212/wnl.46.2.379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.